BALTIC GAS

BALTIC GAS is a 1994 tank ship. The Coast Guard has recorded 30 inspections since 1994, most recently in March 2010, along with 7 deficiencies and 7 operational controls.

Records from 1994 to 2010. Most recent: operational control imposed, 16 March 2010.

Built
1994
Last inspected
16 March 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9034717 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
396716
Flag
VENEZUELA
—
Maury page id
psix-396716

Inspections, by type

…with no type recorded17
Years with a record 13 calendar years (1994–2010)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it18360 - Convention (Subpart B), Gross Ton
5508 - Convention (Subpart B), Net Ton
23256 - Dead Weight, Ton
33312 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

16 March 2010 ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3696802
25 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2808113
19 October 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2803737
19 October 2006 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2804030
17 October 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2802599
27 September 2005 COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2502401
16 June 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2396548
4 June 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2378856
12 August 2004 COC-GAS Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2164341
29 August 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1890577
26 May 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1802577
5 May 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1787092
4 May 2003 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1792536
12 February 2003 Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1744284
3 February 2003 Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1739001
21 April 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1634096
19 April 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1610976
2 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280633
9 December 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 435384
9 December 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 811643
25 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 484732
3 December 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 423414
3 December 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 808409
11 November 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 152322
13 June 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 404663
2 July 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 392904
2 July 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086443
7 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1161543
6 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 374988
3 February 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1457154

Deficiency record · 7

Pollution Prevention/Response › Prevention Equipment › Automatic Back Pressure Shut-off
Issued 16 March 2010 Resolved
Vessel automatic shut-off valve on the loadline to cargo tank #2 portside is not operating properly and closing in the required time. Prior to loading vessel must make repairs to the satisfaction of certificate issuing authority to all loading valves. IGC 19783 Ed Ch 13.3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2010
Resolution: Rcvd class report attesting to repairs of automatics shut-off valves number 2 and 3 port side close within 30 seconds and
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 16 March 2010 Resolved
Vessel deck water spray has 20-30 clogged spray nozzles thorough out the system. Prior to discharge cargo vessel must make proper repairs to the satisfaction of the certificate issuing authority. IGC 1983 Ed Ch11.3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2010
Resolution: Water spray valves were repaired to the satisfaction of the attending Surveyor.
Construction/Loadline › Markings › Load Line Mark
Issued 19 October 2006 Resolved
Loadline not permanently marked on the side of the ship.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 21 November 2006
Resolution: Received proper verification satisfying requirement.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 19 October 2006 Resolved
Vsl could not properly calibrate and test the fixed gas detection system. Vsl must provide a class report attesting to the proper operation prior to conducting.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2006
Resolved 20 October 2006
Resolution: Received class report stating the vessel''s fixed gas detection system is fully operational.
Documentation › Certificates/Documents › Certificate of Compliance (Fish)
Issued 19 October 2006 Resolved
COC could not be issued since the vsl did not apply for a new Sub O endorsement through the Marine Safety Center.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2006
Resolved 19 October 2006
Resolution: Vsl recieved approval for Sub O endorsement. Endorsed and issed COC and Sub O Endorsement
Deck/Cargo › Inert Gas System
Issued 12 February 2003 Resolved
Low O2 level shutdown-alarm inop.
Action required: 705 - Other - as specified
Resolved 4 May 2003
Resolution: Tested and found satisfactory.
Deck/Cargo › Inert Gas System
Issued 12 February 2003 Resolved
High level O2 alarm that directs gas overboard through gas regulating valve is Inop.
Action required: 705 - Other - as specified
Resolved 4 May 2003
Resolution: Tested and found satisfactory during COC-G Exam.

Ownership record