MAURY USCG vessel records Sign in
← All vessels

KALEBAH

KALEBAH is a 1993 freight ship. The Coast Guard has recorded 42 inspections since 1993, most recently in April 2024, along with 24 deficiencies and 4 operational controls.

Records from 1993 to 2024. Most recent: inspection, 4 April 2024.

Built
1993
Last inspected
4 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8913710 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
397330
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-397330

Inspections, by type

…with no type recorded24
Years with a record 16 calendar years (1993–2024)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5999 - Convention (Subpart B), Gross Ton
5999 - Regulatory (Subpart C or D), Gross Ton
3075 - Convention (Subpart B), Net Ton
3075 - Regulatory (Subpart C or D), Net Ton
6886 - Dead Weight, Ton
10777 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 42

4 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7889919
29 March 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3704822
28 March 2010 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3704551
16 March 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3696780
25 January 2009 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3399697
28 October 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3334818
1 October 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3336883
27 March 2005 Ballast Water Examination · MARPOL Annex V Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2319539
25 March 2005 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2319783
21 March 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2315827
17 March 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2312780
13 March 2005 NPV Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2308722
31 January 2005 Ballast Water Examination · NPV Safety Exam · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2283159
27 January 2005 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2281550
11 January 2005 NPV Safety Exam · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2272764
11 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2277007
2 October 2004 ISPS II Exam · MARPOL Annex I Examination · STCW 95 Exam · PII Safety Exam · MARPOL Annex V Examination · ILO-147 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2211608
12 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2130232
29 June 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2114954
4 April 2004 Ballast Water Examination · MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2037018
5 September 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1891432
29 March 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1598986
10 February 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1485299
11 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 282063
30 November 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 435215
11 August 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 431508
23 September 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 420522
12 August 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 524091
20 September 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 408085
18 August 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 406959
10 June 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 404358
28 February 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 697539
19 February 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 163786
20 January 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 399645
16 September 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 395509
2 May 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 203249
2 May 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 757525
20 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 389142
24 March 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 376458
20 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 376546
14 April 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 513704
29 November 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 445601

Deficiency record · 24

Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 29 March 2010 Resolved
Vessel experienced casualty outside US waters and was deadship towed into the Pot of Miami. Def issued to identify cause of loss of power and attest to the proper repair and operation of machinery. RO must provide class survey report to USCG prior to movement. The vessel must undergo PSC exam once class survey report is received. NOTE: PSC exam waived. See narrative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2010
Resolution: Received class survey report attesting to the cause of engine trouble.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 17 March 2010 Resolved
Gyro compass repeater in the steering flat is off by 80 degrees.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Engineering › Steering Gear System › Rudder Stock
Issued 17 March 2010 Resolved
Steering gear unit is hunting 5 degrees when it reaches between 30-35 degrees. Unit cannot maintain rudder angle.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 17 March 2010 Resolved
Vessel does not have a standard discharge connection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 March 2010 Resolved
The CO2 bottles for all of the fixed fire-fighting sytems are overdue for a servicing by 5 months. Vessel could not provide documentation that these dates were extended.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 March 2010 Resolved
All of the portable dry-chemical fire extinguishers were overdue by 5 months for service. Vessel could not provide documentation that these dates had been extended.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Construction/Loadline › Structures › Door
Issued 17 March 2010 Resolved
Door leading to crew locker room from the maindeck could be sealed shut thus compromising weathertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Construction/Loadline › Structures › Manhole
Issued 17 March 2010 Resolved
Hatch leading to the bosun locker from the forepeak is missing the gasket thus compromising weathertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 March 2010 Resolved
Various wires, circuitry and lighting around the vessel has been left uncovered and/or exposed.
Action required: 705 - Other - as specified
Due 24 March 2010
Resolved 4 April 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami's Open Deficiencies List.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 March 2010 Resolved
Switchboards for the emergency generator and bow thruster do not have non-conductive matting in the front or rear of them.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 4 April 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami's Open Deficiencies List.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 17 March 2010 Resolved
Emergency generator does not have a secondary source of start.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2010
Resolution: Received class survey report from GL attesting to proper repair and operation.
Documentation › Logs/Records › Logbook (official)
Issued 16 March 2010 Resolved
The deck log has not been filled out in accordance with the vessel's SMS. It is lacking information regarding navigational activities and incidents.
Action required: 705 - Other - as specified
Due 16 March 2010
Resolved 4 April 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami's Open Deficiencies List.
Fire Fighting › Structural - A Class Divisions › Pantries
Issued 2 October 2004 Resolved
Fire plan needed to updated.
Due 2 November 2004
Resolved 2 October 2004
Resolution: provided new copy of Fire Plan
Fire Fighting › Emergency Fire Pumps
Issued 5 September 2003 Resolved
Class to address lack of pressure of emergency fire pump prior to 30 oct 2003. LEGACY COMPONENT DESC: Pressure
Action required: 705 - Other - as specified
Due 30 October 2003
Resolved 4 April 2004
Resolution: EMERGENCY FIRE PUMP DEMONSTRATED ADEQUATE PRESSURE.
Fire Fighting › Miscellaneous Items
Issued 5 September 2003 Resolved
Replace handles on class A-60 doors located in emergency control room and A/C room prior to 05 Oct 2003. LEGACY COMPONENT DESC: A Class Division Penetrations
Condition: Improper/Lack of Maintenance
Due 5 October 2003
Resolved 4 April 2004
Resolution: HANDLES HAVE BEEN REPLACED.
Lifesaving › Liferaft Equipment
Issued 10 February 2002 Resolved
Provide launching instructions for portside davit launched liferaft. LEGACY COMPONENT DESC: Instructions (immediate action)
Condition: Unknown
Due 10 March 2002
Resolved 24 February 2002
Documentation › Certificates/Documents
Issued 10 February 2002 Resolved
Have Class address name change on Minimum Safe Manninng Document. LEGACY COMPONENT DESC: Minimum Safe Manning Document
Due 10 March 2002
Resolved 24 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 10 February 2002 Resolved
Have Class attest to satisfactory repairs and operation of OWS. Retain oily waste on board and dispose to approved shoreside facility until deficiency cleared. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 10 March 2002
Resolved 29 March 2002
Resolution: Cleared 29MAR02.
Documentation › Safety/Response Plans/Programs
Issued 10 February 2002 Resolved
Update local port contact information in SOPEP to include MSO Miami and Port of Miami information. LEGACY COMPONENT DESC: SOPEP
Due 10 March 2002
Resolved 24 February 2002
Engineering › Lubricating Oil Service System
Issued 10 February 2002 Resolved
Repair leaks to main lubricating pumps 1&2 for main engine. LEGACY COMPONENT DESC: Pump
Due 10 March 2002
Resolved 29 March 2002
Resolution: Cleared 29MAR02.
Fire Fighting
Issued 11 September 2000 Resolved
Repair air flow indicators (missing or not actuated) in smoke detection cabinet for CO2 system.
Condition: Unknown
Due 18 December 2000
Resolved 19 December 2000
Documentation
Issued 11 September 2000 Resolved
Provide legible DCM for container of matches prior to loading.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Lifesaving
Issued 11 September 2000 Resolved
Install stbd davit type liferaft IAW with Safety Equipment Certificate; currently, liferaft does not have a quick release hook & the crane will notreach to engage the liferaft for launching.
Condition: Unknown
Due 18 December 2000
Resolved 19 December 2000
Navigation
Issued 20 March 1995 Resolved
A VIO OF 33 CFR 164.11(q) IN THAT THE TEST REQUIRED BY 33 CFR 164.25(a) WERE NOT CONDUCTED WITH IN 12 HOURS PRIOR TO ENTERING THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 21 March 1995
Resolved 23 March 1995

Ownership record