MAURY USCG vessel records
← All vessels

UNITY

Built
2001
Last inspected
25 March 2021
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2021
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9221607
Flag
CYPRUS
Maury page id
psix-39737

Documentation record

Tonnage as PSIX records it25246 - Convention (Subpart B), Net Ton
84361 - Displacement, Ton
74133 - Dead Weight, Ton
39035 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 5 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

25 March 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7162581
24 October 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6830726
5 October 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6549319
8 December 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6316525
5 January 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5792276

Deficiency record · 3

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 March 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Aux Boiler Blowdown OVBD discharge had a temporary repair cement patch between the hull and the first valve in the pipe which was below the waterline. 74 SOLAS (14) I/11(a)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: Class examined temporary repair and considered it satisfactory until dry dock scheduled this year.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 March 2021 Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. 2000L of cylinder oil was stored on the Aft main deck, directly next to the oxygen and acetyline compartments. Crew pumped oil to the cylinder oil tank in the engine room.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 25 March 2021
Resolved 25 March 2021
Resolution: Crew pumped the oil to the cylinder tank in the engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 5 January 2016 Resolved
The Machinery shall be of a design and construction adequate for the service for which they are intended. No. 3 & 4 fuel injectors of the main engine malfunctioned. 74 Solas (as ammended)II-1 26.1
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2016
Resolved 5 January 2016
Resolution: No. 3 & 4 fuel injectors of the main engine replaced.

Ownership record