Records from 1995 to 2017. Most recent: inspection, 3 April 2017.
Inspection history · 10
3 April 2017
ISPS II Exam · PII Safety Exam · COE-Dockside · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6116513
4 November 2015
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5754670
7 December 2011
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4203472
11 August 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4111404
6 September 2008
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3320812
11 July 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2423180
9 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2422603
19 July 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 406237
16 October 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 383745
16 October 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 652997
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 April 2017
No resolution recorded
PSCO observed a smoke detector above the stern thrust converter. crew was unable to test and stated it was wired in to the stern thrust converter to shut it down.
74SOLAS I/II
50ac
Due 3 May 2017 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 April 2017
No resolution recorded
PSCO Observed an opening approximately 1.5 inches in the forward bulkhead of the steering room.
74SOLAS I/II
50ac
Due 3 May 2017 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 April 2017
No resolution recorded
PSCO Observed the emergency generator hydraulic hand pump start system has excessive oil leaks that are not being maintained.
74SOLAS I/II
50ac
Due 3 May 2017 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 11 August 2011
Resolved
0999- After any survey of the ship no change shall be made in the structual arrangements, machinery, equipment covered by the survey without sanction of the administration. The fuel supply line from day tank to the deck generator and pump has a small fuel leak. Also the deck generator pump needs to be replaced due to excessive fuel leaks. Solas 74 Chap I Reg 11 code 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2011
Resolved 8 December 2011
Resolution: Vessel replaced line and also rebuilt deck generator pump. No leaks were noted
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 11 July 2005
Resolved
Bulkhead and ceiling panels are missing or holed in engine control room. Repair/replace as original.
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 30 April 2008
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 July 2005
Resolved
Vessel unable to provide evidence of a static liquid pressure test of its bunker line. Provide evidence of test, attested to by Master and Chief Engineer.
Action required: 705 - Other - as specified
Due 3 August 2005
Resolved 30 April 2008
Lifesaving
Issued 19 July 1997
Resolved
SOLAS III Reg. 3.1: Personal Flotation lights (McMurdo Marine V.K. Model L285) were missing rubber plugs thereby exposing battery to moisture which results in its activation. Requirement to replace prior to next U.S. Port,but not later than 05Aug97.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Electrical
Issued 19 July 1997
Resolved
SOLAS II-2 REG. 40, Starboard side pilot embarkation ladder LIGHT not satifactory due to damaged lens. Light bulb was exposed and created an electrical hazard. Required vessel to repair prior to next U.S. Port call.
Condition: Unknown
Due 5 August 1997
Resolved 6 August 1997
Documentation
Issued 16 October 1995
Resolved
WHILE CONDUCTING AN ANNUAL EXAM ON THE SUBJECT VESSEL, FOUND THAT THE VESSEL WAS MISSING THE LIST OF PRODUCTS TRANSFERED, DESCRIPTION OF EACH OILTRANSFER SYSTEM, DESC. OF EMPTYING MANIFOLD, NUMBER OF PERSONS REQUIRED, PROC. AND DUTY FOR TENDING MOORINGS, COMMS MEANS, AND REPORTING DISCHARGES.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997