MAURY USCG vessel records Sign in
← All vessels

PACIFIC GUARDIAN

PACIFIC GUARDIAN is a 1983 industrial vessel. The Coast Guard has recorded 10 inspections since 1995, most recently in April 2017, along with 9 deficiencies — 3 with no resolution recorded — and 1 operational control.

Records from 1995 to 2017. Most recent: inspection, 3 April 2017.

Built
1983
Last inspected
3 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8222941 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
397461
Flag
UNITED KINGDOM
—
Maury page id
psix-397461

Inspections, by type

…with no type recorded4
…past their stated due date3
Years with a record 7 calendar years (1995–2017)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it6133 - Convention (Subpart B), Gross Ton
1839 - Convention (Subpart B), Net Ton
11508 - Displacement, Ton
7526 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

3 April 2017 ISPS II Exam · PII Safety Exam · COE-Dockside · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6116513
4 November 2015 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5754670
7 December 2011 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4203472
11 August 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4111404
6 September 2008 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3320812
11 July 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2423180
9 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2422603
19 July 1997 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 406237
16 October 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 383745
16 October 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 652997

Deficiency record · 9

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 April 2017 No resolution recorded
PSCO observed a smoke detector above the stern thrust converter. crew was unable to test and stated it was wired in to the stern thrust converter to shut it down. 74SOLAS I/II 50ac
Due 3 May 2017 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 April 2017 No resolution recorded
PSCO Observed an opening approximately 1.5 inches in the forward bulkhead of the steering room. 74SOLAS I/II 50ac
Due 3 May 2017 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 April 2017 No resolution recorded
PSCO Observed the emergency generator hydraulic hand pump start system has excessive oil leaks that are not being maintained. 74SOLAS I/II 50ac
Due 3 May 2017 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 11 August 2011 Resolved
0999- After any survey of the ship no change shall be made in the structual arrangements, machinery, equipment covered by the survey without sanction of the administration. The fuel supply line from day tank to the deck generator and pump has a small fuel leak. Also the deck generator pump needs to be replaced due to excessive fuel leaks. Solas 74 Chap I Reg 11 code 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 September 2011
Resolved 8 December 2011
Resolution: Vessel replaced line and also rebuilt deck generator pump. No leaks were noted
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 11 July 2005 Resolved
Bulkhead and ceiling panels are missing or holed in engine control room. Repair/replace as original.
Action required: 705 - Other - as specified
Due 11 August 2005
Resolved 30 April 2008
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 11 July 2005 Resolved
Vessel unable to provide evidence of a static liquid pressure test of its bunker line. Provide evidence of test, attested to by Master and Chief Engineer.
Action required: 705 - Other - as specified
Due 3 August 2005
Resolved 30 April 2008
Lifesaving
Issued 19 July 1997 Resolved
SOLAS III Reg. 3.1: Personal Flotation lights (McMurdo Marine V.K. Model L285) were missing rubber plugs thereby exposing battery to moisture which results in its activation. Requirement to replace prior to next U.S. Port,but not later than 05Aug97.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Electrical
Issued 19 July 1997 Resolved
SOLAS II-2 REG. 40, Starboard side pilot embarkation ladder LIGHT not satifactory due to damaged lens. Light bulb was exposed and created an electrical hazard. Required vessel to repair prior to next U.S. Port call.
Condition: Unknown
Due 5 August 1997
Resolved 6 August 1997
Documentation
Issued 16 October 1995 Resolved
WHILE CONDUCTING AN ANNUAL EXAM ON THE SUBJECT VESSEL, FOUND THAT THE VESSEL WAS MISSING THE LIST OF PRODUCTS TRANSFERED, DESCRIPTION OF EACH OILTRANSFER SYSTEM, DESC. OF EMPTYING MANIFOLD, NUMBER OF PERSONS REQUIRED, PROC. AND DUTY FOR TENDING MOORINGS, COMMS MEANS, AND REPORTING DISCHARGES.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.