MAURY USCG vessel records
← All vessels

PACIFIC GUARDIAN

PACIFIC GUARDIAN is a 1983 industrial vessel. The Coast Guard has recorded 1 inspection in 2017, along with 3 deficiencies — 3 with no resolution recorded —.

Records in 2017. Most recent: inspection, 3 April 2017.

Built
1983
Last inspected
3 April 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 April 2017
…past their stated due date3
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8222941
397461
Flag
UNITED KINGDOM
Maury page id
psix-397461

Documentation record

Tonnage as PSIX records it6133 - Convention (Subpart B), Gross Ton
1839 - Convention (Subpart B), Net Ton
11508 - Displacement, Ton
7526 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

3 April 2017 ISPS II Exam · PII Safety Exam · COE-Dockside · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6116513

Deficiency record · 3

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 April 2017 No resolution recorded
PSCO observed a smoke detector above the stern thrust converter. crew was unable to test and stated it was wired in to the stern thrust converter to shut it down. 74SOLAS I/II 50ac
Due 3 May 2017 — due date passed with no resolution recorded
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 April 2017 No resolution recorded
PSCO Observed an opening approximately 1.5 inches in the forward bulkhead of the steering room. 74SOLAS I/II 50ac
Due 3 May 2017 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 April 2017 No resolution recorded
PSCO Observed the emergency generator hydraulic hand pump start system has excessive oil leaks that are not being maintained. 74SOLAS I/II 50ac
Due 3 May 2017 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.