Records from 1995 to 2010. Most recent: inspection, 1 November 2010.
Inspection history · 32
1 November 2010
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3876361
14 September 2010
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3844471
24 December 2009
Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3654845
10 February 2009
MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3412261
23 June 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3245392
19 June 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3241187
15 February 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3144216
11 May 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2646422
8 April 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2331198
5 April 2005
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2326627
23 October 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1695009
21 October 2002
Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1693233
9 October 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 294390
1 August 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 292118
8 March 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 287692
18 July 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 279775
8 February 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 273891
2 February 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 274100
18 July 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 430460
20 November 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 182854
20 November 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 422938
25 July 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 417983
2 February 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 412236
5 November 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 409468
14 July 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 405434
24 October 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 396200
19 October 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 57900
12 August 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 394196
8 June 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 392104
7 December 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 385504
19 September 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 382806
5 May 1995
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 378243
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 September 2010
Resolved
1530-Radar- Both of the ships radars are displaying incorrect heading and one of the radar is unable to acquire and plot the range and bearing of other vessels. SOLAS 2004 cons V/19
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2010
Resolution: 17 SEPT 2010: Received class report from [name withheld] stating all outstanding deficiencies have been rectified. The class report stated, installed a new PCB, tested ARPA Function and unit tracks target, also verified that the radars gyro compass corre
Engineering › Lubricating Oil Service System › Pump
Issued 10 February 2009
Resolved
Vessel has minor leaking from both lube oil pumps.
Action required: 705 - Other - as specified
Due 24 February 2009
Resolved 20 October 2009
Resolution: Received, reviewed and accepted class report and proper documentation from CCS stating the deficiency was rectified. (Leaks were repaired.)
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 10 February 2009
Resolved
During the inspection of the sewage holding tank several leaks and soft patches were noted.
Action required: 705 - Other - as specified
Due 24 February 2009
Resolved 20 October 2009
Resolution: Received, reviewed and accepted class report / proper documentation from CCS stating the deficiency was rectified. (leaks were repaired.)
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 June 2008
Resolved
The vessel's radar was inoperative and not transmitting.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2008
Resolved 23 June 2008
Resolution: Received proper documentation rectifying the deficiency.
Construction/Loadline › Structures › Door
Issued 5 April 2005
Resolved
The following doors failed to maintain watertight and/or weather tight integrity: forward paint locker, 2 of 2 forecastle, 2 of 2 emergency fire pump space, and door to steering gear space. Class to attend and make recommendations for repairs prior to departure. (ILLC 66 Annex I/15)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 11 April 2005
Resolution: Rcv''d Class Report (CCS) dated 08Apr05 Survey No. NY050037.
Construction/Loadline › Hull › Side Shell
Issued 5 April 2005
Resolved
Base of fairlead roller holed/wasted, aft stbd corner. Class to attend and attest to repairs. (ILLC 66 Annex I/Chap I Reg I)
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 11 April 2005
Resolution: Rcv''d Class Report (CCS) dated 08Apr05 Survey No. NY050037. Repairs were made.
Engineering › Fuel Oil Service System › Piping
Issued 5 April 2005
Resolved
Welded doubler on main engine fuel oil heater inlet line. Class to attend and make recommendations for repairs. (SOLAS 74(A) I/II)
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 11 April 2005
Resolution: Rcv''d Class Report (CCS) dated 08Apr05 Survey No.NY050037. Fuel oil heater inlet line was cropped and renewed.
Fire Fighting › Fire Pumps › Suction Valve
Issued 5 April 2005
Resolved
Bilge/Fire pump s/w inlet line valve unable to open preventing operation of pump. Repair to new condition to satisfaction of USCG Marine Inspector prior to departure. (SOLAS 74(A) II-I/21)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 8 April 2005
Resolution: Crew oiled valve and valve is fully operating properly now.
Communications › Alarms/Indicators › Fire Alarm
Issued 5 April 2005
Resolved
Fire Alarm Bell on main deck aft port side iwo Fire Hose Station #13 fails to sound alarm. Repair/replace NLT07 Apr 05 to the satisfaction of the CG Marine Inspector. (SOLAS 74(A)II-2/12)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 8 April 2005
Deck/Cargo › Cargo Stowage › General
Issued 5 April 2005
Resolved
Hydraulic leaks on cargo holds #5, #4, #2, and #1. Pistons leaking as well as high pressure flexible line fittings. Class to attend and make recommendations for repair within 30 days.
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 11 April 2005
Resolution: Rcv''d Class Report (CCS) dated 08Apr05 Survey No.NY050037. High pressure flexible lines were renewed. Outstanding Condition of Class imposed for leaking pistons. To be permanently repaired by 07Jun05.
Engineering › Steam System (auxiliary) › Piping
Issued 5 April 2005
Resolved
Leaking water line above entrance to purifier room. Repair to new condition to satisfaction of USCG Marine Inspector within 30 days. (SOLAS74(A)II-I/26)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2005
Resolved 8 April 2005
Resolution: Piping cropped and renewed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 April 2005
Resolved
#1 SSDG has a weeping weld in the F/W cooling line and S/W cooling line to air cooler. Class to attend and make recommendations for repairs prior to departure. (SOLAS 74(A) II-I/26
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2005
Resolved 11 April 2005
Resolution: Rcv''d Class Report (CCS) dated 08Apr05 Survey No.NY050037. Permanent repairs were effected.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 October 2002
Resolved
ATTENDING MARINE INSPECTOR WITNESSED THE USE OF EMULSIFYING AGENTS AND THAT THESE CHEMICALS ARE IN THE BILGE. THE USE OF EMULSIFYING AGENTS WILL RENDER THE OWS INOPERATIVE. ADMINISTRATION IS TO VERIFY THE PROPER OPERATION OF THE OWS. THE REPORT MUST BE PROVIDED TO THE ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Resolved 5 April 2005
Resolution: Found to be corrected.
Engineering › Freshwater System (jacketwater cooling)
Issued 21 October 2002
Resolved
FOUND BRACKET FOR FRESH WATER EVAPORATOR DISCHARGE AND PURIFIER COOLENT WASTED AT POINT OF PENETRATION OF SIDE SHELL STBD. SIDE. WASTED BRACKETS ARE BETWEEN SHELL AND VALVE. CLASS TO RECOMMEND PERMANENT REPAIR PROPOSAL PRIOR TO DEPARTURE.
Action required: 705 - Other - as specified
Due 21 October 2002
Resolved 28 October 2002
Resolution: CLASS SURVEYOR ATTESTED TO REPAIRS.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 October 2002
Resolved
FOUND MAIN SEA SUCTION PIPE TO HAVE SEVERAL DOUBLERS AND THESE ARE LEAKING. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS.
Action required: 705 - Other - as specified
Due 21 November 2002
Resolved 5 April 2005
Resolution: Permanent repairs made per Class Report (DNV) dated 25 Oct 02.
Engineering › Freshwater System (air cooling)
Issued 21 October 2002
Resolved
WORKSHOP AC DISCHARGE PIPE HAS DOUBLERS IN WAY OF HULL PENETRATIONS INSIDE OF VALVE. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 21 November 2002
Resolved 25 October 2002
Resolution: CLASS ATTESTED TO THE REPAIR AND OPERATION.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 21 October 2002
Resolved
PIPING ASSOCIATED WITH MSD WASTED AND LEAKING FUMES AND LIQUID SUBSTANCES INTO INTERIOR OF VESSEL. MUST BE REPAIRED TO PREVENT THE ESCAPE OF VAPORS AND FLUIDS, TO SATISFACTION OF FLAG STATE. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 705 - Other - as specified
Due 21 November 2002
Resolved 5 April 2005
Resolution: Repaired per Class Report (DNV) dated 25 Oct 02.
Lifesaving › Lifeboat Equipment
Issued 21 October 2002
Resolved
REPLACE DAMAGED FOOD RATIONS 6 PORT AND 19 STBD. FOR A TOTAL OF 25 RATIONS TOTALING NOT LESS THAN 10,000 KJS EACH. FAX RECEIPT TO ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE PORT OF BALTIMORE. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 October 2002
Resolved 25 October 2002
Resolution: CLASS ATTESTED TO THE REPLACEMENT OF DAMAGED FOOD RATIONS.
Fire Fighting › Firemans Outfit
Issued 21 October 2002
Resolved
REPLACE DAMAGED/WORN GLOVES FOR FIREMAN'S OUTFIT. FAX RECEIPT TO COTP BALTIMORE PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Gloves
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 October 2002
Resolved 28 October 2002
Resolution: CLASS ATTESTED TO THE REPLACEMENT OF THE WORN GLOVES.
Fire Fighting › Emergency Fire Pumps
Issued 21 October 2002
Resolved
REPAIR EMERGENCY FIRE PUMP TO THE SATISFACTION OF CLASS. CLASS TO ATTEST TO PROPER OPERATION OF EMERGENCY FIREPUMP PRIOR TO DEPARTURE PORT OF BALTIMORE.
Action required: 705 - Other - as specified
Due 21 October 2002
Resolved 25 October 2002
Resolution: CLASS ATTESTED TO THE REPAIR AND OPERATION.
Lifesaving › Launching Appliances
Issued 21 October 2002
Resolved
REPAIR DAMAGED REMOTE RELEASE FOR PORT LIFEBOAT DAVIT SYSTEM TO SATISFACTION OF CLASS. CLASS TO ATTEST TO THE PROPER OPERATION OF REMOTE RELEASE PRIOR TO DEPARTURE PORT OF BALTIMORE. LEGACY COMPONENT DESC: Release Mechanism
Action required: 705 - Other - as specified
Due 21 October 2002
Resolved 25 October 2002
Resolution: CLASS ATTESTED TO THE REPAIR AND OPERATION.
Deck/Cargo › Holds/Tanks
Issued 21 October 2002
Resolved
REPAIR FUEL VENT ON PORT SIDE FOSCLE PRIOR TO DEPARTURE PORT OF BALTIMORE. LEGACY COMPONENT DESC: Ventilation Exhaust Outlet
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2002
Resolved 25 October 2002
Resolution: CLASS ATTESTED TO THE REPAIR AND OPERATION.
Navigation › Piloting/Steering
Issued 21 October 2002
Resolved
LIGHT IN COMPASS ON BRIDGE IS TOO DIM TO READ. REPAIR PRIOR DEPARTURE PORT OF BALTIMORE. CLASS TO ATTEST TO REPAIR. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 705 - Other - as specified
Due 21 October 2002
Resolved 25 October 2002
Resolution: CLASS ATTESTED TO THE REPAIR AND OPERATION.
Accommodation/Occupational Safety
Issued 1 August 2001
Resolved
Replace or repair as original 20ft section of sewage line stbd. side wastedto the satisfaction of Class and USCG Marine Inspector.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Accommodation/Occupational Safety
Issued 1 August 2001
Resolved
Have Class attest to the proper repair of seawater supply pipe and discharge line on pump above water generator.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Accommodation/Occupational Safety
Issued 1 August 2001
Resolved
Class to reccomend repairs to holed and wasted sections of port and stbd. sewage tanks.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Unknown
Issued 1 August 2001
Resolved
Replace missing guard on engaging mechanism on rear of steam generator.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Lifesaving
Issued 1 August 2001
Resolved
Install covers on stbd. sewage tank pumps.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Navigation
Issued 1 August 2001
Resolved
Vessel to update/renew U.S. Coast Pilot.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 1 August 2001
Resolved
Cargo hold #5 aft port hatch combing gusset crack at weld. 1st gusset inboard from aft port corner. Repair to the satisfaction of Class.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 1 August 2001
Resolved
Cargo hold #1 fwe center of hatch combing in way of gasket seat damage. Repair to the satisfaction of Class.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 1 August 2001
Resolved
Cargo hold #2 fwd center of hatch combing in way of gasket seat damaged total of 2 locations approx 6' apart. Repair to the satisfaction of Class.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Construction/Loadline
Issued 1 August 2001
Resolved
Cargo hold #5 stbd. hatch combing cracked 10ft fwd of aft side. Bottom side located inside of cargo hold. Repair to the satisfaction of Class.
Condition: Unknown
Due 9 October 2001
Resolved 9 October 2001
Navigation
Issued 1 August 2001
Resolved
Vessel to update light list prior to sailing.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Lifesaving
Issued 1 August 2001
Resolved
Port life boat brake must be manually pushed to set brake. Repair to the satisfaction of class.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 1 August 2001
Resolved
Cargo hold #6 fwd. transverse hatch combing in way of hatch table plate wasted. Located midship of hatch combing. Repair to the satisfaction of class.
Condition: Unknown
Due 1 August 2001
Resolved 3 August 2001
Fire Fighting
Issued 18 July 2000
Resolved
Vls class socety to attest to the piping arrangement of the emergency fire pump, which supplies ballast and fire fighting water simultaneously, there for flooding ballest tanks during operation of the system. _x001C_ Solas 74 I/11
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Fire Fighting
Issued 18 July 2000
Resolved
Renew as original, the wasted face mask on the emergency outfit._x001C_ Solas 74 II-2/17
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Lifesaving
Issued 18 July 2000
Resolved
Crew unable to perform satisfactory fire drill. Demonstrate proper fire drill to the satisfaction of the attending Coast Guard Marine Inspector._x001C_ Solas 74 III/18.3
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Accommodation/Occupational Safety
Issued 18 July 2000
Resolved
renew as original, the latch on the freezer room, located in the provision stores. _x001C_ ILO 147
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Construction/Loadline
Issued 18 July 2000
Resolved
Vessel class society to recommend repairs to the lonbgitudinal stiffners oncargo hold#5, Which are holed/ wasted._x001C_ _x001C_ ILLC 66 REG I
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Navigation
Issued 18 July 2000
Resolved
TIDAL CURRENT TABLES MISSING.
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Navigation
Issued 18 July 2000
Resolved
Tide tables missing- Provide.
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Navigation
Issued 18 July 2000
Resolved
U.S. Coast Pilot not updated - Correct
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Construction/Loadline
Issued 18 July 2000
Resolved
Affect permanent repairs to port and stbd lifeboat davit systems in way of aft upper channel, which is wasted. In addition, load test davits to the satisfaction of class as per DNV condition of class ID#19258 (#028)_x001C_ SOLAS 74 III/19.2
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Engineering
Issued 18 July 2000
Resolved
Affect permanent repairs to OWS in way of main seperation tank, which is wasted and holed on the underside. Additionally, class to attest to these repairs, calibration,and proper operation of unit. Marpol Annex 1/16_x001C_ 33 CFR155.380
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Lifesaving
Issued 18 July 2000
Resolved
Affect permanent repairs to the port & stbd lifeboat single point release systems, which are wasted. Vsl class society to attest to proper oprerationto the Satisfaction of the attending Coast Guard Marine Inspector._x001C_ solas 74 III/19.2
Condition: Unknown
Due 18 July 2000
Resolved 21 July 2000
Lifesaving
Issued 25 July 1998
Resolved
PROVIDE USCG BALTIMORE FAXED CONFIRMATION OF SATISFACTORY TEST OF STBD LIFEBOAT ENGINE.
Condition: Unknown
Due 25 July 1998
Resolved 28 July 1998
Construction/Loadline
Issued 14 July 1997
Resolved
CLASS TO ADDRESS FRACTURES ON CARGO HATCH RADUISES IN HOLDS #2, #3, #4, #5AND EXAMINE ALL OTHER RADIUSES IN ALL OTHER HOLDS.
Condition: Unknown
Due 31 January 1998
Resolved 7 November 1997
Lifesaving
Issued 14 July 1997
Resolved
HYDROSTATIC RELEASE FOR EPIRB EXPIRED.
Condition: Unknown
Due 7 November 1997
Resolved 7 November 1997
Navigation
Issued 14 July 1997
Resolved
SUBMIT TECH REPORT TESTIFYING TO PROPER OPERATION OF ARPA PRIOR TO SAILING.
Condition: Unknown
Due 15 July 1997
Resolved 28 July 1997
Construction/Loadline
Issued 19 September 1995
Resolved
MAIN DECK RADIUS CORNERS ON CARGO HATCHES #2 PORT AND STARBOARD FORWARD, #3STARBOARD FORWARD, #4 PORT FORWARD.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Documentation
Issued 5 May 1995
Resolved
MINIMUM SAFE MANNING CERTIFICATE NOT ON BOARD.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Documentation
Issued 5 May 1995
Resolved
OIL TRANSFER PROCEDURES NOT COMPLETE.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995