SAN DIEGO is a 1984 freight ship. The Coast Guard has recorded 41 inspections since 1993, most recently in April 2022, along with 70 deficiencies and 6 operational controls.

Records from 1993 to 2022. Most recent: inspection, 2 April 2022.

Built
1984
Last inspected
2 April 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8421200 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
397859
Flag
BELIZE
—
Maury page id
psix-397859

Inspections, by type

…with no type recorded25
Years with a record 17 calendar years (1993–2022)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it11850 - Dead Weight, Ton
191114 - Displacement, Ton
12383 - Convention (Subpart B), Gross Ton
4780 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 41

2 April 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7423144
21 July 2011 Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4078003
13 September 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3846190
3 April 2009 MARPOL Annex VI Survey · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check · Ballast Water Examination · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3439171
1 April 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3444434
28 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3441990
6 June 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3229081
28 February 2008 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3151143
5 October 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2794125
14 June 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2679874
15 April 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2334446
16 July 2004 ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2135767
8 July 2004 ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2125828
7 July 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2125055
16 June 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2100680
16 May 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2071013
11 May 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2065855
7 May 2004 Administrative Inspection · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2061581
6 November 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1943316
7 July 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1838762
28 May 2003 Re-Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1796484
25 February 2003 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1749126
18 November 2002 Annual Inspection · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1706807
16 November 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 295663
13 November 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 295507
5 May 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 277448
29 February 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 275460
11 May 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 428374
5 March 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 426068
11 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 711029
10 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 394928
22 July 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 380759
19 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 377529
22 June 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 182123
15 June 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 367804
1 December 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 669622
24 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 362703
24 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1431287
22 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 53204
22 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 134142
22 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 140978

Deficiency record · 70

Fire Fighting › Fire Main › Condition
Issued 20 July 2011 Resolved
Fire fighting systems and appliances shall be maintained ready for use. When energized, Fire main's previous repair failed. SOLAS 74 (CONSOLIDATED 09) CH II-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2011
Resolved 3 August 2011
Resolution: Vessel replaced piping on fire main. Adequate pressure was given with emergency fire pump.
Documentation › Certificates/Documents › IOPP Certificate
Issued 20 July 2011 Resolved
The IOPP certificate shall be drawn up in the form corresponding model given in Appendix II. IOPP certificate form A is not drawn up in accordance with MEPC 187 (59). Deficiency to remain outstanding until next survey. MARPOL 73/78 ANNEX I/9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during data pull to have open deficiencies. Vessel is listed as active in MISLE, however multiple sources state vessel was scrapped in 2018, rendering any open deficiencies null and void.
Construction/Loadline › Markings › Load Line Mark
Issued 20 July 2011 Resolved
The ring lines and letters shall be painted in white or yellow on a dark background or black on a light background. Load line is rusted and not painted. ICLL 1966 ANNEX I/8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during data pull to have open deficiencies. Vessel is listed as active in MISLE, however multiple sources state vessel was scrapped in 2018, rendering any open deficiencies null and void.
Stability › Weathertight Integrity › General
Issued 20 July 2011 Resolved
The arrangement for weather tightness shall be maintained in any sea condition. Several hatches on deck are not capable of maintaining weather tightness. ICLL 1966 ANNEX I/16.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during data pull to have open deficiencies. Vessel is listed as active in MISLE, however multiple sources state vessel was scrapped in 2018, rendering any open deficiencies null and void.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 April 2009 Resolved
Vessel crew unable to prove proper operation of unit. Provide report from class attesting to proper operation of unit.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2009
Resolved 16 April 2009
Resolution: Received class and technician report stating unit has been replaced and tested satisfactorily.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 3 April 2009 Resolved
Due to extensive number of deficiencies and the Masters inability to produce the SMS records or documents the USCG recommends an external audit of the vessel.
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 16 April 2009
Resolution: Received RMS Report stating satisfactory audit of SMS system completed.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 3 April 2009 Resolved
All 13 class deficiencies are to be cleared before departure.
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 16 April 2009
Resolution: Received class report reporting all deficiencies cleared to the satisfaction of class.
Navigation › Collision/Grounding Avoidance › Radar
Issued 3 April 2009 Resolved
Stbd radar found inoperable. Provide technician report attesting to proper operation before departure.
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 16 April 2009
Resolution: Received report of Stbd radar being replaced and tested satisfactorily
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 3 April 2009 Resolved
Four of the officers license applications were expired and no flag state license was found on board. Vessel to be manned in accordance with Safe Manning Certificate prior to movement
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 16 April 2009
Resolution: All personnel have appropriate certificates and endorsements. Vessel manned IAW Safe Manning Certificate.
Fire Fighting › Combustible Materials › Grounds
Issued 3 April 2009 Resolved
Extensive work in the engine room has created a fire hazard with excessive oil, water and dirt. Engine room to be cleaned prior to movement.
Action required: 705 - Other - as specified
Due 3 April 2009
Resolved 16 April 2009
Resolution: Engine room cleaned to the satisfaction of class.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 February 2008 Resolved
Engine Room has excessive oil on walkways, and numerous engine parts blocking walkways for emergency egress. NOTE: Vessel was doing Engine overhaul during inspection. Clean engine room to the satisfaction of the Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 June 2008
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 28 February 2008 Resolved
Marine Sanitation device has numerous holes, leaks, and wastage.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 6 June 2008
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
Electrical › Electric Generation Source (emergency) › Generator
Issued 28 February 2008 Resolved
Chief engineer admitted that the air supply line to the emergency generator air start system has a leak and can't maintain required pressure for multiple starts. The air compressor is constantly running to maintain the minimum pressure. Primary method of starting, which is by battery, is working properly.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 6 June 2008
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 14 June 2006 Resolved
Captains flag state endorsement is incorrect. Specifically, current endorsement states he is only authorized to captain ships less than 3000 GT. Prior to departure from port submit current and correct application for flag state endorsement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2006
Resolution: Recieved a fax copy of the Captain''s new application for endorsement from Belize. Ship was cleared to depart port.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 14 June 2006 Resolved
The depth sounding device is unable to continuously record the depth reading. Prior to next US port after sailing foreign repair to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2006
Resolution: Received Class Report stating all navigation equipment is operating correctly.
Engineering › Lubricating Oil Service System › Cooler
Issued 14 June 2006 Resolved
There is a small L/O leak on the #1 generators cooler. Prior to the next US port after sailing foreign repair the L/O cooler to the satisfaction of the class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2006
Resolution: Received Class Report attesting to all machinery equipment running properly.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 14 June 2006 Resolved
There is an excessive amount of oil in the E/R bilges. Prior to next US port after sailing foreign clean bilges tot he satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2006
Resolution: Engine room bilges now free of oil.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 May 2004 Resolved
Vale for S/W pump #1 outlet weaping. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 21 July 2004
Resolution: recieved class report.
Lifesaving › Lifeboat Equipment
Issued 7 May 2004 Resolved
Replace damaged food rations, 15 Port lifeboat and 14 Starboard lifeboat for a total of 29 food ration totaling not less than 10,000 each. Fax receipt to attending U.S.C.G. Marine Inspector. LEGACY COMPONENT DESC: Food Ration
Action required: 705 - Other - as specified
Due 7 May 2004
Resolved 11 May 2004
Resolution: Rcv''d receipt of food rations (40 total) from Vane Bros. dated 10-May-04.
Construction/Loadline › Hull › Weld
Issued 7 May 2004 Resolved
Repair fractured hatch coaming brackets for cargo holds 1,3 and 4 as marked. LEGACY COMPONENT DESC: Bracket
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 27 June 2004
Resolution: Sighted BV class report.
Construction/Loadline › Markings › Load Line Mark
Issued 7 May 2004 Resolved
Load line does not reflect proper Class Society markings. Replace with permanent markings. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 21 July 2004
Resolution: recieved class report.
Construction/Loadline › Hull › Bracket
Issued 7 May 2004 Resolved
Bulwark brackets on Port and STBD side of vessel along cargo area have been cut away from bulwark. Class Surveyor to attest to modification or recommend permanent repairs. LEGACY COMPONENT DESC: Bracket
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 27 June 2004
Resolution: Sighted BV class report.
Construction/Loadline › Markings
Issued 28 May 2003 Resolved
Loadline Marking on Hull did not match Loadline Certificate LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 7 July 2003
Resolution: RECIEVED CLASS REPORT.
Navigation › Piloting/Steering
Issued 28 May 2003 Resolved
Rudder Angle Indicator making unusual noises.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 7 July 2003
Resolution: RECIEVED CLASS REPORT.
Lifesaving › Lifeboat
Issued 28 May 2003 Resolved
Starboard Lifeboat engine missing inlet filter assembly
Due 28 June 2003
Resolved 7 July 2003
Resolution: RECIEVED CLASS REPORT.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 28 May 2003 Resolved
Unable to start w/ hand crank
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2003
Resolution: Demonstrated proper operation of hand crank.
Engineering › Freshwater System (jacketwater cooling)
Issued 18 November 2002 Resolved
AUXILIARY ENGINE FRESH WATER COOLING PIPE LEAKS/WASTED PORT SIDE IN WAY OF BOILER FW PUMP. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Engineering › Freshwater System (air cooling)
Issued 18 November 2002 Resolved
PIPE FOR FRESHWATER FEED TO PROVISIONS STORES IN WAY OF PUMP PORT SIDE AFT ENGINE ROOM LEAKS/WASTED. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Engineering › Freshwater System (piston cooling)
Issued 18 November 2002 Resolved
FRESHWATER FEED PIPE FOR BEARING COOLING LEAKS/WASTED PORT SIDE, LOWER ENGINE ROOM. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Pollution Prevention/Response › Prevention Equipment
Issued 18 November 2002 Resolved
OVERBOARD DISCHARGE VALVES IN WAY OF OILY WATER SEPARATOR APPEARS TO HAVE TEMP. REPAIRS. CLASS TO SURVEY AND MAKE RECOMMENDATIONS FOR PERMANENT REPAIRS, PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Engineering › Freshwater System (jacketwater cooling)
Issued 18 November 2002 Resolved
MAIN ENGINE COOLING WATER PIPE PORT SIDE LEAKS IN WAY OF COUPLING. MAKE PERMANENT REPAIRS TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Engineering › Freshwater System (air cooling)
Issued 18 November 2002 Resolved
FRESH WATER PIPE FOR AC COOLING SYSTEM HAS LARGE SOFT PATCH. MAKE PERMANENT REPAIRS TO SATISFACTION OF FLAG STATE. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Engineering › Sea-water System (primary cooling)
Issued 18 November 2002 Resolved
NUMEROUS VALVES AND PUMPS LEAKING EXCESSIVELY. TIGHTEN/REPAIR AND CONDUCT GENERAL MAINTANCE. CLASS TO ATTEST TO CONDITION OF VALVES AND PUMPS. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Engineering › Generator (propulsion-electric)
Issued 18 November 2002 Resolved
FRESHWATER COOLING HOSES FOR ALL DIESEL GENERATORS LEAKING. MAKE REPAIRS TO SATISFACTION OF CLASS.
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Inflatable Liferafts
Issued 18 November 2002 Resolved
CLASS SURVEYOR TO ATTEST TO INTEGRITY OF STBD. FWD. LIFERAFT (AFT OF LIFEBOAT). CRACK IN TOP OF CASING. LEGACY COMPONENT DESC: Container Construction
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat Equipment
Issued 18 November 2002 Resolved
REPLACE DAMAGED FOOD RATIONS. 14 PORT AND 21 STBD. FOR A TOTAL OF 35 RATIONS TOTALING NOT LESS THAN 10,000 KJ EACH. FAX RECEIPT TO COTP BALTIMORE PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Launching Appliances
Issued 18 November 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST TO PROPER OPERATION OF PORT AND STBD. LIFEBOAT ENTRY HATCH SYSTEMS. HATCHES SECURED BY LINE TO LIFEBOAT. LEGACY COMPONENT DESC: Hatches
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST TO COCKPIT HATCH COVERS ON BOTH PORT AND STBD. LIFEBOATS. REAR WINDOW MISSING ON BOTH. LEGACY COMPONENT DESC: Hatches
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST TO CONDITION OF PORT LIFEBOAT COCKPIT COVER. REPLACE AS ORIGINAL. LEGACY COMPONENT DESC: View (at steering position)
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS SOCIETY TO ADDRESS CRACK IN PORT LIFEBOAT STBD SIDE AFT ON THE INTERIOR. MAKE RECOMMENDATION FOR REPAIRS. LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS TO ATTEST TO PROPER OPERATION OF STBD LIFEBOAT ENGINE EXHAUST SYSTEM. EXCESSIVE EXHAUST INSIDE LIFEBOAT WHEN STARTED. LEGACY COMPONENT DESC: Exhaust Pipe
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS SURVEYOR TO ATTEST TO PORT AND STBDL LIFEBOAT INTERIOR BRACING JOINTS. TWO ARE BUCKLED AND CRACKED ON THE INSIDE OF STBD LIFEBOAT, AS MARKED. LEGACY COMPONENT DESC: Stability
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Lifesaving › Lifeboat
Issued 18 November 2002 Resolved
CLASS SURVEYOR TO ATTEST TO GENERAL CONDITION OF BOTH PORT AND STBD LIFEBOAT HULLS. LAMINATE PULLING AWAY. LEGACY COMPONENT DESC: Hull
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Construction/Loadline › Hull
Issued 18 November 2002 Resolved
CLASS SURVEYOR TO ATTEST TO HOLE IN BULKHEAD, LOCATED FWD OF STBD LIFEBOAT JUST ABOVE DECK LINE, AT BOTTOM OF LADDER WELL. MAKE RECOMMENDATION FOR REPAIR.
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Deck/Cargo › Mooring/Anchoring
Issued 18 November 2002 Resolved
AFT MOORING LINE SPOOLS WASTED AT THE FOUNDATIONS. MAKE PERMANENT REPAIRS TO SATISFACTION OF FLAG STATE. LEGACY COMPONENT DESC: Capstan
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 February 2003
Resolution: REPAIRS SUCCESFULLY COMPLETED
Construction/Loadline › Structures
Issued 18 November 2002 Resolved
REPAIR/REPLACE ALL LADDER RUNS ATTACHED TO DECK HOUSES. LADDER RUNGS WASTED.
Action required: 705 - Other - as specified
Due 18 December 2002
Resolved 25 February 2003
Resolution: REPAIRS COMPLETED
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
REMOVE JERRY RIGGED WIRING IN CENTER DECK HOUSE. PANEL BOX NEST TO REFRIGERATION SYSTEM. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Accommodation/Occupational Safety › Occupational Safety
Issued 18 November 2002 Resolved
REMOVE JERRY RIGGED WIRING FROM ELECTRICAL PANEL BOX LOCATED IN FIRST DECK HOUSE FWD OF MAIN DECK HOUSE. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Deck/Cargo › Holds/Tanks
Issued 18 November 2002 Resolved
REPAIR VENT COVERS STBD SIDE BUNKER STATION. BOTH VENT COVERS WASTED. LEGACY COMPONENT DESC: Ventilation Exhaust Trunking
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 25 November 2002
Resolution: Class report
Engineering
Issued 16 November 2001 Resolved
Vessel to provide adequate containment of 42 gal capacity for all tanks w/external venting, prior to return to the U.S. Presently IFO tank 1.16 & 1.17 have proper containment along w/aft stern bunker manifold. All other IFO, MGO, LO and sludge tks are to be provided w/ containment. 33CFR155.32
Condition: Unknown
Due 30 November 2001
Resolved 18 November 2002
Engineering
Issued 13 November 2001 Resolved
VESSEL TO PROVIDE ADEQUETE CONTAINMENT AROUND EACH FUEL OIL, AND LUBE OIL TANK VENT, OVER FLOW, AND FILL PIPE. 33CFR 155.320, TOBE COMPLETED PRIOR TONEXT US PORT.
Condition: Unknown
Due 21 November 2001
Resolved 21 November 2001
Lifesaving
Issued 5 May 2000 Resolved
Prove proper operation of port lifeboat engine. SOLAS 74(unamend) III/9(a)
Condition: Unknown
Due 5 May 2000
Resolved 15 May 2000
Engineering
Issued 5 March 1999 Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF OILY WATER PIPING IN WAY OF THE LOWER LEVEL ENGINEROOM OVERHEAD FORWARD._x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Engineering
Issued 5 March 1999 Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF SALTWATER COOLING PIPING FOR THE TURBOCHARGER IN WAY OF THE 2ND DECK ENGINEROOM, STARBOARD SIDE._x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Fire Fighting
Issued 5 March 1999 Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN PIPING IN WAY OF THE #2 FIRE PUMP DISCHARGE._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Engineering
Issued 5 March 1999 Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF SALTWATER COOLING PIPING FOR THE MAIN AND AUXILLARY ENGINES IN WAY OF THE #1 PUMP DISCHARGE._x001C_ SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Documentation
Issued 5 March 1999 Resolved
PROPERLY DENOTE ALL APPROVED COLLECTION TANK CAPACITIES ON THE VESSEL'S IOPP CERTIFICATE WHERE APPROPRIATE._x001C_ MARPOL 73/78 ANNEX I/5
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Lifesaving
Issued 10 September 1996 Resolved
PROVIDE ONBOARD 4KG QUICK RELEASE BRIDGE BUOYS WITH SMOKE AND QUICK RELEASEMECHANISM._x001C_ SEE SOLAS 74 AMENDED III/31.7
Condition: Unknown
Due 14 September 1996
Resolved 17 September 1996
Documentation
Issued 10 September 1996 Resolved
CONDUCT ANNUAL SURVEY OF THE CARGO SHIP SAFETY EQUIPMENT CERTIFICATE._x001C_ SEE SOLAS 74 AMENDED I/12(iii), APP 1.
Condition: Unknown
Due 14 September 1996
Resolved 17 September 1996
Documentation
Issued 10 September 1996 Resolved
PROVIDE OIL TRANSFER PROCEDURES PRIOR TO BUNKERING OR TRANSFERING OIL ONBOARD VESSEL._x001C_ SEE 33 C.F.R. 155.720
Condition: Unknown
Due 14 September 1996
Resolved 17 September 1996
Navigation
Issued 10 September 1996 Resolved
PROVE PROPER OPERATION OF AUTOMATED RADAR PLOTTING AID._x001C_ SEE 33 C.F.R. 164.38
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Engineering
Issued 10 September 1996 Resolved
PROVE PROPER OPERATION OF 15PPM OILY WATER SEPERATOR WITH ALARM AND AUTOMATIC STOPPING DEVICE._x001C_ SEE MARPOL 73/78 AN/16
Condition: Unknown
Due 14 September 1996
Resolved 17 September 1996
Fire Fighting
Issued 10 September 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER PIPING IN WAY OF THE #2 BALLAST PUMP IN ENGINEROOM._x001C_ SEE SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Fire Fighting
Issued 10 September 1996 Resolved
PROVIDE ENGLISH TRANSLATION OF FIREFIGHTING INSTRUCTIONS POSTED THROUGHOUT THE VESSEL._x001C_ SEE SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 14 September 1996
Resolved 16 October 1996
Electrical
Issued 10 September 1996 Resolved
PROVE PROPER OPERATION OF EMERGENCY DIESEL GENERATOR._x001C_ SEE SOLAS 74 AMENDED II-1/43
Condition: Unknown
Due 14 September 1996
Resolved 17 September 1996
Fire Fighting
Issued 10 September 1996 Resolved
REPAIR OR REPLACE LOW PRESSURE ALARM TO MASK TO FIREMANS SUIT._x001C_ SEE SOLAS 74 AMENDED II-2/27
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Engineering
Issued 19 April 1995 Resolved
OILY-WATER SEPARATOR NOT OPERATING PROPERLY.
Condition: Unknown
Due 25 April 1995
Resolved 24 April 1995
Engineering
Issued 19 April 1995 Resolved
#1 GENERATOR HAS A CYLINDER WHICH IS LEAKING COOLING WATER.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Engineering
Issued 19 April 1995 Resolved
ALL GENERATORS IN NEED OF GENERAL REPAIR AND MAINTENENCE.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.