Records from 1993 to 2018. Most recent: inspection, 18 April 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
18 April 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6395774
5 December 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446156
22 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 685441
20 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 152365
5 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166201
20 January 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 851655
10 December 1993
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397995
Lifesaving
Issued 10 December 1993
Resolved
PROVIDE DEVICE FOR BREAKING GLASS AT EACH EMERGENCY CONTACT MAKER.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Lifesaving
Issued 10 December 1993
Resolved
INSTALL GENERAL ALARM SIGNS AT THE FOLLOWING LOCATIONS: MUD PUMP RM, MCC8, SACK STOWAGE DOORWAY, CELLAR DECK FWD, WELDER SHOP FWD, DRILL FLOOR, AND DRILLER'S HOUSE.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Lifesaving
Issued 10 December 1993
Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS: PORT ENGINE ROOM AFT, MCC8, SACK STOWAGE DOORWAY, WELDER'S SHOP FWD, STARBOARD ENGINE ROOM FAN HOUSE, LOGGERSHACK, AND GEOLOGIST OFFICE.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Engineering
Issued 10 December 1993
Resolved
PROVIDE ABS SURVEY REPORT OF PROPULSION THRUSTER REPAIRS.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
HYDRO AIRBOTTLES IN ALL LIFEBOATS.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 10 December 1993
Resolved
RENEW HELICOPTER WIND DIRECTION INDICATOR.
Condition: Unknown
Due 22 December 1993
Resolved 22 December 1993
Fire Fighting
Issued 10 December 1993
Resolved
PROVIDE FIRE SERVICE REPORT.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Construction/Loadline
Issued 10 December 1993
Resolved
CLEAN OIL ON DECK IN THE THRUSTER ROOMS.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Accommodation/Occupational Safety
Issued 10 December 1993
Resolved
REPAIR SELF CLOSING DOOR AND ARRANGE TO OPEN INTO NON-HAZARDOUS SPACE (DOORTO BOP CONTROL ROOM).
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 10 December 1993
Resolved
PROVIDE FLAME SCREENS FOR GEAR OIL TANK VENTS-DRILL FLOOR.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Navigation
Issued 10 December 1993
Resolved
REPAIR INOP. NAVIAGATION LIGHTS AS NECESSARY.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Deck/Cargo
Issued 10 December 1993
Resolved
MAKE SHALE SHAKE AVAILABLE FOR INSPECTION UPON COMPLETION OF INSTALLATION.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993