HERCULES 152

HERCULES 152 is a 1980 mobile offshore drilling unit. The Coast Guard has recorded 47 inspections since 1995, most recently in December 2011, along with 94 deficiencies.

Records from 1995 to 2011. Most recent: inspection, 2 December 2011.

Built
1980
Last inspected
2 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8756502 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
398045
Flag
LIBERIA
—
Maury page id
psix-398045

Inspections, by type

…with no type recorded8
Years with a record 16 calendar years (1995–2011)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3169 - Regulatory (Subpart C or D), Gross Ton
3169 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 47

2 December 2011 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4200477
1 December 2011 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4200046
20 January 2009 Deficiency Check · COC-MODU Annual
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3418478
11 August 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3295360
23 January 2008 Deficiency Check · COC-MODU Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3199965
18 April 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2925955
22 March 2007 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2882301
9 March 2007 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2884892
2 March 2006 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2594738
21 February 2006 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2589420
5 January 2006 COC-MODU Renew
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2565872
11 January 2005 COC-MODU Annual
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2256519
15 February 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2025386
13 January 2004 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1959045
21 April 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1777572
10 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1755183
26 January 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735480
13 January 2003 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1730337
14 December 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718929
15 November 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1708784
9 January 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1476946
7 December 2001 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1076933
31 May 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066398
31 May 2001 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1068517
13 March 2001 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1060834
22 January 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1468185
10 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 41450
2 March 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1046871
18 February 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 817416
24 January 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1432256
25 January 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381455
17 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807783
31 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130475
23 June 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792595
13 March 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1108421
5 March 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 786360
26 January 1998 Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1422961
21 April 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1106316
1 April 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093654
7 February 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380765
16 May 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1083420
21 February 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 123658
18 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1467453
17 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1385621
5 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873988
19 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878830
9 January 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466925

Deficiency record · 94

Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 February 2009 Resolved
Renew main deck watertight hatch gasket prior to rig movement.
Action required: 705 - Other - as specified
Due 2 March 2009
Resolved 9 February 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 February 2009 Resolved
Survey and renew deteriorated ladder and landing from main deck to drill floor.
Action required: 705 - Other - as specified
Due 27 February 2009
Resolved 9 February 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 February 2009 Resolved
Prove proper operation of draw works blower interlocks prior to conducting drilling operations.
Due 2 March 2009
Resolved 9 February 2009
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 February 2009 Resolved
Properly adjust "A" class fire doors in stairwell.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 9 February 2009
Deck/Cargo › Cargo Transfer (solid) › General
Issued 20 January 2009 Resolved
Complete required crane repairs and tests to the satisfaction of ABS and attending marine inspector.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 2 February 2009
Personnel › Training › Lifeboatman
Issued 20 January 2009 Resolved
Provide the required lifeboatmen (2) for each boat for a total of (4).
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 2 February 2009
Operations/Management › Drills/Instruction › Fire
Issued 20 January 2009 Resolved
Complete fire fighting training and perform dirll to the satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 2 February 2009
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 20 January 2009 Resolved
Complete class survey and provide full term certificates.
Action required: 705 - Other - as specified
Due 6 February 2009
Resolved 2 February 2009
Operations/Management › Drills/Instruction › Fire
Issued 23 January 2008 Resolved
Provide adequate fire fighting training for ARAMARK service personnel on activitation of galley fixed fire extinguishing unit
Due 23 February 2008
Resolved 22 February 2008
Resolution: OIM verified that all personnel on both hitches had been trainined on the proper activiation of the system.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 January 2008 Resolved
Replace expired medications in medicine chest.
Condition: Improper/Lack of Maintenance
Due 23 February 2008
Resolved 22 February 2008
Resolution: OIM verified all medicines had been replaced
Lifesaving › Lifeboat › Exhaust Pipe
Issued 23 January 2008 Resolved
Correct the cause of the exhaust leak in the #2 Stbd lifeboat
Condition: Unknown
Due 23 February 2008
Resolved 22 February 2008
Resolution: Vessel''s crew renewed the flexible exhaust pipe.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 23 January 2008 Resolved
Replace or renew door frame for door between the mud pit rm and the mud pump room to obtain a proper seal.
Condition: Improper/Lack of Maintenance
Due 23 February 2008
Resolved 22 February 2008
Resolution: Door frame was welded as necessary
Engineering › Generator (propulsion-electric) › Reverse Power Protection Relay Circuitry
Issued 22 March 2007 Resolved
Unable to test Reverse Power Relay and emergency Shut-downs due to drilling operations. Requested to have Flag State/Class check within 30 days.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 23 January 2008
Resolution: Tested RPR and reviewed rig test records for emergency shut down.
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 22 March 2007 Resolved
Expired Anti-seasickness Medicine in both Lifeboats.
Action required: 705 - Other - as specified
Due 30 March 2007
Resolved 23 January 2008
Resolution: Cleared during COC exam
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 22 March 2007 Resolved
Class 'A' door on Main deck Stairwell needed to be replaced. Door did not have a means to close without assistance and door did not fully close.
Action required: 705 - Other - as specified
Due 30 March 2007
Resolved 23 January 2008
Resolution: Cleared during COC exam
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 22 March 2007 Resolved
Class 'A' Door on Paint Locker did not have a latch to keep it closed. Provide a appropriate latch for the door.
Action required: 705 - Other - as specified
Due 30 March 2007
Resolved 23 January 2008
Resolution: Cleared during COC renewal
Construction/Loadline › Structures › Door
Issued 5 January 2006 Resolved
Demonstrate proper operation of all local visual alarms for watertight doors.
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Construction/Loadline › Structures › Door
Issued 5 January 2006 Resolved
Demonstrate proper operation of all watertight door alarms at panel in Tool Pusher Office - and provide means to identify specific doors.
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 January 2006 Resolved
Properly repair damaged cable transit in WT bulkhead between SCR & compressor rooms.
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Electrical › Electric Generation Source (service) › Generator
Issued 5 January 2006 Resolved
Replace broken start air gauge on #1 EMD.
Action required: 705 - Other - as specified
Due 5 February 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 January 2006 Resolved
Renew broken port light between SCR and engine room as original.
Action required: 705 - Other - as specified
Due 5 February 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 January 2006 Resolved
Repair wasted supply air ductwork in air compressor room.
Action required: 705 - Other - as specified
Due 5 February 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Engineering › Bilge Water Management System › Manifold
Issued 5 January 2006 Resolved
Make permanent repairs to wasted bilge manifold (currently temp repaired).
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Accommodation/Occupational Safety › Ventilation › General
Issued 5 January 2006 Resolved
Demonstrate proper operation of mud pit loss-of-vacuum alarm located on drill floor.
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 January 2006 Resolved
Make permanent repairs to self closing mechanism on paint locker door (door will not close).
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Construction/Loadline › Structures › Door
Issued 5 January 2006 Resolved
Adjust watertight doors #7 & #8 to ensure WT integrity (currently not sealing).
Action required: 705 - Other - as specified
Due 19 January 2006
Resolved 2 March 2006
Resolution: Received ABS report #BV680726 attesting to completion of requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 January 2005 Resolved
Repair or replace galley entry door to comply with "A" class boudary requirements reflected in rig fire control plan.
Due 18 January 2005
Resolved 12 January 2005
Resolution: Repaired galley door.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 11 January 2005 Resolved
Replace 2 STBD liferafts with 2 davit launchable liferafts.
Condition: Unknown
Due 12 January 2005
Resolved 12 January 2005
Resolution: Replaced with 2 davit launchable life rafts.
Electrical › Electrical Distribution System (service)
Issued 9 January 2002 Resolved
Locate and remove 440 volt ground on main distribution panel, located in Switch Gear Room. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Due 15 February 2002
Resolved 21 January 2002
Resolution: Galley AC compressor grounded- replaced compressor.
Fire Fighting › Structural Fire Protection - General
Issued 9 January 2002 Resolved
Provide and Install door closure for Paint Locker door
Condition: Unknown
Due 15 February 2002
Resolved 21 January 2002
Resolution: Installed door closure. device.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 January 2002 Resolved
Provide closure on port side Helicopter safety netting. (Netting has gap next to Port Ladder, Design Flaw) LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Design Flaw
Due 15 February 2002
Resolved 16 January 2002
Resolution: Installed brace and covered hole with expanded metal.
Operations/Management › FireFighting
Issued 9 January 2002 Resolved
Conduct Fire & Boat drill when unit is crewed.
Due 15 February 2002
Resolved 6 February 2002
Operations/Management › Drills/Instruction
Issued 9 January 2002 Resolved
Conduct drill when full crew complement aboard. LEGACY COMPONENT DESC: Fire
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2002
Operations/Management › Drills/Instruction
Issued 9 January 2002 Resolved
Conduct drill when full crew complement is aboard. LEGACY COMPONENT DESC: Abandon Ship
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2002
Documentation
Issued 22 January 2001 Resolved
Provide approved copy of Emergency Evacuation Plan onboard.
Condition: Unknown
Due 2 February 2001
Resolved 13 February 2001
Electrical
Issued 22 January 2001 Resolved
Clean seals on all explosion-proof fittings located on the Drill Floor.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Engineering
Issued 22 January 2001 Resolved
Repair and label emergency fuel cutout valve for fuel oil purifier and provide updated system drawing for fuel oil distribuion piping.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Navigation
Issued 22 January 2001 Resolved
Crop and renew port and starboard aft obstruction light bases.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Construction/Loadline
Issued 22 January 2001 Resolved
Crop and renew inboard longitudinal frame, port side, lifeboat platform.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Fire Fighting
Issued 22 January 2001 Resolved
Make permanent repairs to general service/fire main piping in way of manifold above fire pump.
Condition: Unknown
Due 22 January 2001
Resolved 22 January 2001
Lifesaving
Issued 24 January 2000 Resolved
Lower to the water and operate the port lifeboat.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Electrical
Issued 24 January 2000 Resolved
Demonstrate proper operation of Emergency Generator automatic starting and load assumption function.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 24 January 2000 Resolved
Provide renewal CO2 bottle for galley fixed firefighting system.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Engineering
Issued 24 January 2000 Resolved
Renew fuel oil hose for port crane.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Construction/Loadline
Issued 24 January 2000 Resolved
Repair and demonstrate proper operation of galley weather deck watertight door.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 24 January 2000 Resolved
Provide current servicing for portable fire extinguishers at fire stations 15, 3, and 37._x001C_ _x001C_
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Documentation
Issued 24 January 2000 Resolved
Submit and obtain approval for Emergency Evacuation Plan prior to engaging in any operations on the Outer Continental Shelf.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Lifesaving
Issued 24 January 2000 Resolved
Locate and repair cracks to Number Two Generator lube oil filter housing.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 24 January 2000 Resolved
Demonstrate operation of Number One Fire Pump with power sourced from Emergency Generator.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Lifesaving
Issued 24 January 2000 Resolved
Conduct release gear tests on port and starboard davit launched liferafts.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Fire Fighting
Issued 24 January 2000 Resolved
Conduct hydrostatic testing of nitrogen bottle at Station 2.
Condition: Unknown
Due 24 January 2000
Resolved 24 January 2000
Deck/Cargo
Issued 25 January 1999 Resolved
IN STBD CRANE, INSTALL HAND SIGNAL CHART, REPLACE CRACKED CAB WINDOW, REPLACE/MOUNT FIRE EXTINGUISHER, AND PROVIDE ADD'L BOOM ANGLE INDICATOR ON PORT SIDE OF BOOM WHERE VIEW IS OBSTRUCTED. IN PORT CRANE, INSTALL HAND SIGNAL CHART, INSTALL FIRE EXTINGUISHER BRACKET, AND SECURE DEAD END WIRES.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Lifesaving
Issued 25 January 1999 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 110% OR SUBMIT AN ALTERNATIVE TEST ACCEPTABLE TO COGNIZANT OCMI.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Construction/Loadline
Issued 25 January 1999 Resolved
COMPLETE ABS SURVEY REPORT OF OUTSTANDING DEFICIENCIES ISSUED ON 20DEC98, REGARDING SSH4, LL AND ANNUAL MODU CODE.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Lifesaving
Issued 25 January 1999 Resolved
CONDUCT LIFESAVING AND FIREFIGHTING TRAINING WITH CREW AND INDUSTRIAL PERSONNEL WITHIN EVERY TWO MONTH PERIOD AND RECORD PROPERLY.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Electrical
Issued 25 January 1999 Resolved
CONDUCT SEMIANNUAL LOAD TEST ON EMERGENCY BATTERIES AND RECORD PROPERLY.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Lifesaving
Issued 25 January 1999 Resolved
CONDUCT LINE THROWING APPLIANCE TRAINING WITH CREW AND INDUSTRIAL PERSONNELEVERY THREE MONTHS AND RECORD PROPERLY.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Lifesaving
Issued 25 January 1999 Resolved
IMPLEMENT LIFERAFT DAVIT TRAINING WITH CREW AND INDUSTRIAL PERSONNEL EVERY FOUR MONTHS AND RECORD PROPERLY.
Condition: Unknown
Due 25 January 1999
Resolved 25 January 1999
Fire Fighting
Issued 26 January 1998 Resolved
REPLACE 12 FT FIRE MONITOR ON FIRE STATION #3 DUE TO SEVERE WASTAGE._x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Engineering
Issued 26 January 1998 Resolved
PROVE PROPER OPERATION OF NO 2 FUEL OIL TRANSFER PUMP._x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
IMPLEMENT TRAINING/FIRE/ABANDOMENT TRAINING AS PER 46 CFR 108/109.
Condition: Unknown
Due 26 February 1998
Resolved 19 February 1998
Engineering
Issued 26 January 1998 Resolved
PROVIDE GUARDS FOR FUEL TANK IN MUD PIT ROOM-ENGINE OIL TANK.
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Fire Fighting
Issued 26 January 1998 Resolved
PROVIDE APPROVED FIRE EXTINGUISHERS WHERE LISTED IN FIRE PROTECTION_x001C_ SERVICE REPORT DATED 13NOV97.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
MAKE GAS TIGHT, SELF CLOSING DOOR IN MUD PIT ROOM, ADJACENT TO EYE WASH STATION.
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Electrical
Issued 26 January 1998 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR.
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Lifesaving
Issued 26 January 1998 Resolved
REGLUE WATERTIGHT GASKET ON RIGHT DOOR ON NO 1 LIFEBOAT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Lifesaving
Issued 26 January 1998 Resolved
PROCURE 5 CARTRIDGES FOR LINETHROWING GUN KIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Fire Fighting
Issued 26 January 1998 Resolved
REPLACE PIPING ON FIRE STATIONS N0 6 AND 10 DUE TO WASTAGE.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Electrical
Issued 26 January 1998 Resolved
MARK LETTER E ON EMERGENCY LIGHTS AT EMBARKATION STATIONS.
Condition: Unknown
Due 26 January 1998
Resolved 2 February 1998
Lifesaving
Issued 26 January 1998 Resolved
PROVIDE PURGE ALARM ARRANGEMENT FOR 480V POWER PANEL ON DRILL FLOOR.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Lifesaving
Issued 26 January 1998 Resolved
PROVIDE REPLACEMENT CO2 CYLINDER FOR EMD SHUTDOWN SYSTEM.
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Lifesaving
Issued 26 January 1998 Resolved
PROVIDE DUST COVERS FOR MUD PIT ROOM EYEWASH STATION AND DRILL FLOOR EYEWASH STATION.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Electrical
Issued 26 January 1998 Resolved
MARK LETTER E ON LIGHTING IN SPARE STORES, SACK ROOM, GEN ROOM AND MUD PUMPROOM.
Condition: Unknown
Due 27 January 1998
Resolved 2 February 1998
Lifesaving
Issued 26 January 1998 Resolved
PERMANENTLY MOUNT GENERAL ALARM SIGN IN SHALE SHAKER HOUSE.
Condition: Unknown
Due 26 February 1998
Resolved 19 February 1998
Lifesaving
Issued 26 January 1998 Resolved
REPAIR WATER LEAK IN BILGE AREA LIFEBOAT 2. SMALL 1/8IN HOLE IN FIBERGLASS NEAR WATER COOLING LINE VALVE.
Condition: Unknown
Due 26 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 7 February 1997 Resolved
REPLACE GASKET FOR WATERTIGHT DOOR BETWEEN AIR COMPRESSOR ROOM AND MUD PIT ROOM.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Construction/Loadline
Issued 7 February 1997 Resolved
REPAIR WASTED T-CONNECTION IN SALTWATER SEACHEST DISCHARGE PIPING ABOVE BILGE PUMP IN MOTOR ROOM.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Electrical
Issued 7 February 1997 Resolved
AT NEXT RIG MOVE, FUNCTION TEST TOTAL RIG SHUTDOWN FROM ALL STATIONS AND MAIN GENERATOR SHUTDOWN PRESSURE SWITCH ASSOCIATED WITH FIXED HALON SYSTEM TO MOTOR ROOM.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Electrical
Issued 7 February 1997 Resolved
PROVIDE PROPER MEANS OF SECURING DOOR OF 480V DISTRIBUTION PANEL #8 MAIN SWITCHBOARD CIRCUIT #6.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Electrical
Issued 7 February 1997 Resolved
REPLACE COUPLING BRUSH IN OIL PUMP TO #1 MAIN GENERATOR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Fire Fighting
Issued 7 February 1997 Resolved
LABEL "OPEN" AND "CLOSED" POSITIONS OF ALL VENTILATION FIRE DAMPENERS.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Accommodation/Occupational Safety
Issued 7 February 1997 Resolved
REPLACE MISSING HANDRAILS AT EMBARKATION AREA FOR LIFERAFT #3.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 7 February 1997 Resolved
PERFORM ANNUAL PROOF LOAD TEST OF BOTH LIFERAFT DAVIT HOOKS AND SUBMIT COPYOF SUBSEQUENT TEST REPORT TO MARINE SAFETY OFFICE PORT ARTHUR.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 7 February 1997 Resolved
POST AT EACH LIFERAFT DAVIT, OPERATING INSTRUCTIONS FOR EACH DAVIT.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Construction/Loadline
Issued 7 February 1997 Resolved
PROPERLY ADJUST FIT AND DOGS FOR MAINDECK WATERTIGHT DOOR BY BOP CONTROL PANEL.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Fire Fighting
Issued 7 February 1997 Resolved
REPLACE FOG APPLICATOR AT FIRE STATION #12 WITH AN APPLICATOR THAT FITS PROPERLY ONTO THE FIRE NOZZLE AT THAT STATION.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Electrical
Issued 7 February 1997 Resolved
INSTALL MECHANICAL GUARDS ON ALL SIGHTGLASSES ON EXPANSION TANK FOR THE MAIN GENERATORS.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 7 February 1997 Resolved
PROPERLY LABEL GENERAL ALARM LIGHT ABOVE #2 MAIN GENERATOR TO READ "GENERALALARM. WHEN LIGHT FLASHES, GO TO YOUR STATION."
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Unknown
Issued 18 January 1996 Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION, TO COAST GUARD INSPECTOR, THE AIR RECEIVERS ON THE RIG FLOOR AND AIR COMPRESSOR ROOM AT NEXT RIG MOVE.
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Lifesaving
Issued 18 January 1996 Resolved
PROVIDE USCG WITH PROOF OF LOAD TEST OF BOTH LIFERAFT DAVITS AND RELEASING GEAR.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Lifesaving
Issued 9 January 1995 Resolved
MAINTAIN STANDBY/CREW BOAT ON SCENE AT RIG UNTIL REPAIRS TO LIFEBOAT ARE COMPLETED.
Condition: Unknown
Due 26 January 1995
Resolved 13 February 1995
Electrical
Issued 9 January 1995 Resolved
PROVE PROPER TESTING OF ALL RIG EMERGENCY SHUT DOWNS (VENTILATION, GENERATOR).
Condition: Unknown
Due 26 January 1995
Resolved 13 February 1995
Navigation
Issued 9 January 1995 Resolved
RENEW NAV LIGHTS--PROPER ANGLES OF ILLUMINATION & PROPER MARINE TYPE BAYONET FITTINGS & BULBS.
Condition: Unknown
Due 26 January 1995
Resolved 13 February 1995
Lifesaving
Issued 9 January 1995 Resolved
STENCIL HOMEPORT ON ALL LIFE JACKETS.
Condition: Unknown
Due 26 January 1995
Resolved 13 February 1995

Ownership record