Inspection record

Last inspected 25 June 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCO6852
398107
Flag
UNITED STATES
Maury page id
psix-398107

Documentation record

Registered dimensions (L × B × D)33.5 ft × 11.8 ft × 3.5 ft
Registered tonnagegross 9 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT INDUSTRIES · WARREN, RI, UNITED STATES · built 1993
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLINCOLN, RI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

25 June 2026 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8412055
30 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8334155
24 June 2025 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8165637
26 June 2024 Damage Survey · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7943363
4 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7877924
21 June 2023 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7703942
7 June 2022 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7449906
19 April 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7422784
31 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7276319
30 September 2020 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7063486
14 April 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6926129
30 July 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6752956
9 April 2019 Examination of Repairs · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6658740
6 August 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6497677
7 June 2018 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6437084
19 April 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6395053
25 July 2017 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6215105
15 August 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5969086
15 August 2016 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5989466

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 August 2021 Resolved
A vessel on a rivers route must carry 3 red hand flares and 3 orange smoke distress signals or 6 red hand flares onboard. Vessel only has 4 red hand flares total.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 2 September 2021
Resolution: New flares purchased and placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length but not more than 6 feet in length, securing the waterlight around the body of the ring life buoy. Waterlight line is too short.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2021
Resolved 2 September 2021
Resolution: Waterlight line changed and is now correct length.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 August 2018 Resolved
Repair / replace unservicable portable extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 August 2018
Resolved 6 August 2018
Resolution: Replaced with new.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 June 2018 Resolved
Conduct a drydock and internal structural exam prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Completed credit dry dock / internal structures exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 7 June 2018 Resolved
Found crack in passenger access ramp to side shell weld seam.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2018
Resolved 6 July 2018
Resolution: Weld crack fixed test weld seam sat.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2017 Resolved
Expiring alcohol test strips, provide new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 26 July 2017
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 July 2017 Resolved
Full compliment of crew not onboard, provide full compliment of crew as listed on COI that are enrolled in DAPI program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 July 2017
Resolved 26 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 July 2017 Resolved
Aspirn is expired. Provide new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 26 July 2017
Lifesaving › Hand Flares › Expired
Issued 25 July 2017 Resolved
Flares were expiring. Provide new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 26 July 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 15 August 2016 Resolved
Properly mount all available portable fire extinguishers in approved brackets.
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 31 August 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 August 2016 Resolved
Provide current certificate of documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2016
Resolution: Vsl rep showed proof of required subittal to NVDC to get back in good standing. CID agreed this would suffice as proof of DOC.