PAUL RICKMERS is a 1993 freight ship. The Coast Guard has recorded 15 inspections since 2003, most recently in July 2009, along with 4 deficiencies and 3 operational controls.

Records from 2003 to 2009. Most recent: operational control imposed, 29 July 2009.

Built
1993
Last inspected
29 July 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9070852 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
398229
Flag
LUXEMBOURG
—
Maury page id
psix-398229

Inspections, by type

…with no type recorded8
Years with a record 4 calendar years (2003–2009)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14069 - Dead Weight, Ton
19843 - Displacement, Ton
10733 - Convention (Subpart B), Gross Ton
5478 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

29 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3545943
29 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3550066
23 June 2008 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3245212
27 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2178437
27 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2178622
25 June 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2110713
24 June 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2110011
14 May 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2067274
23 April 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2050658
19 February 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2012262
27 January 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1994022
25 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1801053
23 May 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1799532
26 March 2003 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1763371
11 February 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1743307

Deficiency record · 4

Engineering › Steering Gear System
Issued 11 February 2003 Resolved
Several leaks on steering gear system. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 27 March 2003
Resolution: Cleared By [name withheld]
Engineering › Lubricating Oil Service System
Issued 11 February 2003 Resolved
Seal on number one main lube oil pump is worn.
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 1 April 2003
Resolution: Class survey issued. Cleared Deficiency.
Documentation › Manuals/Policy Documentation
Issued 11 February 2003 Resolved
Vessel does not have oil transfer procedures. Fax completed procedures to MSO Miami. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 703 - Prior to bunkering operations
Due 11 February 2003
Resolved 23 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 11 February 2003 Resolved
Missing chain in large gap in rail on deck below lifeboat embarkation deck. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 28 February 2003
Resolved 1 April 2003
Resolution: Chain connected to gap.

Ownership record