MAURY USCG vessel records
← All vessels

PACIFIC MERMAID

PACIFIC MERMAID is a 1991 freight ship. The Coast Guard has recorded 28 inspections since 2016, most recently in July 2026, along with 7 deficiencies and 7 operational controls.

Records from 2016 to 2026. Most recent: inspection, 7 July 2026.

Built
1991
Last inspected
7 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9045924
398350
Flag
LIBERIA
Maury page id
psix-398350

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded8
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it10466 - Dead Weight, Ton
15999 - Displacement, Ton
9820 - Convention (Subpart B), Gross Ton
3538 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 28

7 July 2026 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8431320
5 July 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8430158
12 November 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8267265
8 October 2025 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8249271
7 October 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8249224
26 June 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7723594
22 June 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7720526
6 February 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7631991
18 October 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7579393
21 August 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7539424
15 March 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7411765
24 January 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7385017
15 October 2021 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7333556
28 July 2021 COE-Offshore · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7270243
26 July 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7268816
25 January 2021 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7130084
11 December 2020 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7110338
1 July 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6992309
3 October 2019 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6826994
19 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6666176
15 April 2019 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6662402
10 April 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659806
9 April 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659109
2 July 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6463775
21 January 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6340938
3 November 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6295960
2 November 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6299451
11 September 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5997616

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 July 2026 Resolved
IN A SHIP WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION, AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED SATURATED LAGGING AND LEAKING ON RETURN LINE TO F.O. SERVICE RETURN TANK.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2026
Resolved 9 July 2026
Resolution: PSCO received class survey of repair.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2025 Resolved
All bulkheads required to be "B" class divisions shall extend from deck to deck and to the shell or other boundaries. PSCO observed a gap pentrating through a class "B" bulkhead in the radio room to the bridge. 74 SOLAS (97) 11-2/43.1 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 12 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 January 2021 Resolved
The machinery and associated piping systems shall be so installed and protected as to reduce to a minimum any danger to persons on board. Temporary repair on lube oil pump casing on number three generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2021
Resolved 28 January 2021
Resolution: Recieved class report confirming repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Excessive leakage was found on pump seal of reefer cooling salt water pump No. 2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 January 2021
Resolved 28 January 2021
Resolution: Recieved class report confirming repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 15 April 2019 Resolved
01-14199- The arrangement on board the ship for the extraction of samples from the 15ppm bilge alarm should give a truly representative sample of the effluent with adequate pressure and flow. PSCO observed a valve installed in the sample extraction line. This valve is not included in the vessel's approved piping diagram. PSCO believes the installed valve in the sample line can prevent the OCM from recieving a truly representative sample of the effluent.-MARPOL 73/78 ANNEX 1 REG 14.7 / MEDC 107(49)6.2.2- 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: See class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2019 Resolved
02-13199- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed the top corner of housing on #1 generator cut out and covered with duct tape. Exposed wires underneath.-74SOLAS(14)I/11-17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: See class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2019 Resolved
03-13199-Terminations and joints in all conductors shall so be made as to retain the origonal electrical, mechanical, flame-retarding and, where necessary, fire-resisting, properties of the cable. PSCO found multiple wires improperly terminated in engine room. Flourscent tube light rear of main engine and lube oil pump for generator no.1 both removed and wires only taped. Power not secured to either and procedures in SMS not followed.-74SOLAS(04)#-1/45..5.6-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: see class report

Ownership record