PACIFIC MERMAID is a 1991 freight ship. The Coast Guard has recorded 48 inspections since 1993, most recently in July 2026, along with 22 deficiencies and 8 operational controls.

Records from 1993 to 2026. Most recent: inspection, 7 July 2026.

Built
1991
Last inspected
7 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9045924 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
398350
Flag
LIBERIA
—
Maury page id
psix-398350

Inspections, by type

…with no type recorded22
Years with a record 22 calendar years (1993–2026)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it10466 - Dead Weight, Ton
15999 - Displacement, Ton
9820 - Convention (Subpart B), Gross Ton
3538 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 48

7 July 2026 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8431320
5 July 2026 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8430158
12 November 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8267265
8 October 2025 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8249271
7 October 2025 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8249224
26 June 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7723594
22 June 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7720526
6 February 2023 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7631991
18 October 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7579393
21 August 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7539424
15 March 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7411765
24 January 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7385017
15 October 2021 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7333556
28 July 2021 COE-Offshore · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7270243
26 July 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7268816
25 January 2021 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7130084
11 December 2020 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7110338
1 July 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6992309
3 October 2019 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6826994
19 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6666176
15 April 2019 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6662402
10 April 2019 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659806
9 April 2019 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6659109
2 July 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6463775
21 January 2018 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6340938
3 November 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6295960
2 November 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6299451
11 September 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5997616
3 February 2011 Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3938616
3 February 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3939059
12 February 2008 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3142028
2 January 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2847604
19 February 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2009450
14 February 2004 Annual Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2006866
2 September 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1894272
2 February 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1738683
2 December 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713288
25 June 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 291270
13 February 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 287033
17 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286045
14 March 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 275688
21 February 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274925
26 January 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 387384
30 November 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385345
19 October 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 383944
21 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374451
1 May 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 366503
7 December 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 362913

Deficiency record · 22

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 July 2026 Resolved
IN A SHIP WHICH OIL FUEL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION, AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED SATURATED LAGGING AND LEAKING ON RETURN LINE TO F.O. SERVICE RETURN TANK.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2026
Resolved 9 July 2026
Resolution: PSCO received class survey of repair.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 October 2025 Resolved
All bulkheads required to be "B" class divisions shall extend from deck to deck and to the shell or other boundaries. PSCO observed a gap pentrating through a class "B" bulkhead in the radio room to the bridge. 74 SOLAS (97) 11-2/43.1 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2025
Resolved 12 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 January 2021 Resolved
The machinery and associated piping systems shall be so installed and protected as to reduce to a minimum any danger to persons on board. Temporary repair on lube oil pump casing on number three generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2021
Resolved 28 January 2021
Resolution: Recieved class report confirming repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 January 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Excessive leakage was found on pump seal of reefer cooling salt water pump No. 2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 January 2021
Resolved 28 January 2021
Resolution: Recieved class report confirming repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 15 April 2019 Resolved
01-14199- The arrangement on board the ship for the extraction of samples from the 15ppm bilge alarm should give a truly representative sample of the effluent with adequate pressure and flow. PSCO observed a valve installed in the sample extraction line. This valve is not included in the vessel's approved piping diagram. PSCO believes the installed valve in the sample line can prevent the OCM from recieving a truly representative sample of the effluent.-MARPOL 73/78 ANNEX 1 REG 14.7 / MEDC 107(49)6.2.2- 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: See class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2019 Resolved
02-13199- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed the top corner of housing on #1 generator cut out and covered with duct tape. Exposed wires underneath.-74SOLAS(14)I/11-17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: See class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2019 Resolved
03-13199-Terminations and joints in all conductors shall so be made as to retain the origonal electrical, mechanical, flame-retarding and, where necessary, fire-resisting, properties of the cable. PSCO found multiple wires improperly terminated in engine room. Flourscent tube light rear of main engine and lube oil pump for generator no.1 both removed and wires only taped. Power not secured to either and procedures in SMS not followed.-74SOLAS(04)#-1/45..5.6-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: see class report
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (air start)
Issued 4 February 2011 Resolved
1410-The condition of the ship shall be maintained vessel suffered a loss of propulsion. Main Engine (M/E) is unable to start. Vessel's crew is unable to discover the cause of the malfunction. SOLAS 74 (2009 Cons Ed) CHI/REG 11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2011
Resolution: Sector Delaware received a Class Report stating that the pilot valves in the starting air distributor were cleaned and new O-rings were fitted. The vessel''''s propulsion was then tested ahead and astern with satisfactory results.
Engineering › Steam Boiler (auxiliary/waste heat) › Shell
Issued 12 February 2008 Resolved
The Insulation in the outer shell of the ships boiler is heavily burnt from a possible combustion gas leak. The possible gas leak and the failure of the insulation present a fire hazard to the ship and crew. Vessel does not use boiler underway, crew uses economizer restrict use of boiler until proper operation verified by class.
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 23 February 2008
Resolution: Class rpt scanned & attached.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 12 February 2008 Resolved
The alarms to collection of leakages from the external high pressure fuel delivery system were not operational. The engineers were able to get them operational, but the alarm signals were very sporadic. Chief engineer said he has ordered replacement parts, but could not produce a requisition order for parts.(DEF. 1,2,&3 ship service diesel generator)
Action required: 705 - Other - as specified
Due 19 February 2008
Resolved 23 February 2008
Resolution: Class rpt scanned & attached.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 2 January 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 January 2007
Resolution: Vessel was able to provide to uscg Liberian endorsement for the chief engineers national liscense.
Lifesaving › Launching Appliances
Issued 2 December 2002 Resolved
0030- Port Lifeboat hooks will not release automatically. Solas Ch. III Reg. 20-2. Repair/Correct prior to departure to the satisfaction of USCG foreign vessel inspector. LEGACY COMPONENT DESC: Release Mechanism
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2002
Navigation › Piloting/Steering
Issued 2 December 2002 Resolved
1560- Vessel missing chart 1081 (british admiralty). 33 CFR 164.33(b). Provide proof that vessel has recieved chart prior to departure. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2002
Fire Fighting
Issued 13 February 2001 Resolved
ONE OF THE VESSEL'S TWO FIREFIGHTING SUITS WAS LACKING AN OPERABLE FLASHLIGHT, THE SECOND WAS MISSING A FLASHLIGHT AND AXE, A VIOLATION OF SOLAS 74/78 CH II-2 REG 17/1.1. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Electrical
Issued 13 February 2001 Resolved
SECONDARY BATTERY BANK FOR WOULD NOT START THE VESSEL'S EMERGENCY GENERATOR, A VIOLATION OF SOLAS 74/78 CH II-1 REG 44/2. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Construction/Loadline
Issued 26 January 1996 Resolved
VESSELS LOADLINE PLIMSOL NOT PERMANENTLY AFFIXED TO HULL. MAKE REPAIRS TO SATISFACTION OF CLASS PRIOR TO NEXT US PORT.
Condition: Unknown
Due 17 January 2001
Resolved 18 January 2001
Electrical
Issued 26 January 1996 Resolved
DEAD END WIRE ON MAIN DECK INSIDE OF ENTRANCE TO STEERING ROOM. TO BE REPAIRED TO THE SATISFACTION OF CLASS. PRIOR TO NEXT US PORT._x001C_
Condition: Unknown
Due 27 January 1996
Resolved 14 February 1996
Navigation
Issued 26 January 1996 Resolved
FOLLOW UP DID NOT FUNCTION DURING OPERATIONAL TEST ON #2 STEERING PUMP. _x001C_ ITEM TO BE CORRECTED TO SATISFACION OF CLASS PRIOR TO NEXT US PORT.
Condition: Unknown
Due 27 January 1996
Resolved 14 February 1996
Lifesaving
Issued 19 October 1995 Resolved
HYDROSTATIC RELEASE ON EPIRB IS EXPIRED._x001C_ SOLAS CHAPTER IV, REGULATION 14-2._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 December 1995
Resolved 1 December 1995
Navigation
Issued 7 December 1993 Resolved
COAST PILOT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Navigation
Issued 7 December 1993 Resolved
pre-arrival tests not logged in vessel's logbook.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Navigation
Issued 7 December 1993 Resolved
CHART OF AREA TRANSITED NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994

Ownership record