MAURY USCG vessel records
← All vessels

MIKE SEKUL

Built
1994
Last inspected
17 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 July 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCL2004
398356
Flag
UNITED STATES
Maury page id
psix-398356

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.7 ft × 4.7 ft
Registered tonnagegross 19 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBAY MARINE BOATWORKS INC · BILOXI, MS, UNITED STATES · built 1994
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portBILOXI, MS
Endorsements, as the file codes themcw_un
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 24 inspections, each with its date, unit and type; 59 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 24

17 July 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8437181
9 February 2026 Drydock Exam · Hull Examination · Vessel Attendance · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308107
3 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8087617
15 April 2024 In-Service Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7895634
5 January 2024 Hull Examination · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7845570
27 June 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7725102
15 November 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7594544
3 January 2022 Examination of Repairs · Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374917
31 March 2021 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7166124
6 May 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949311
7 January 2020 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6885356
9 April 2019 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6659053
28 March 2019 Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6651391
8 March 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6368673
26 January 2018 Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6344161
19 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6153312
19 April 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6128591
3 March 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6098510
26 September 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6010035
18 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5881170
14 April 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5854500
31 March 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5844344
14 March 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833203
21 January 2016 Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5801352

Deficiency record · 59

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 April 2024 Resolved
a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 4 June 2024
Resolution: Vessel downloaded electronic versions of all charts and pubs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel had a breathalizer that was not calibrated per manufacturers instructions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Vessel purchased new alcohol testing strips.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Vessel has the annual servicing sticker but did not have the annual servicing paperwork. Vessel needs to provide annual servicing paperwork.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 5 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 June 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel’s stern light is inoperable. Vessel needs to fix stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel replaced stern nav light.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 June 2023 Resolved
46 CFR 183.430 Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Portable light at the operating station did not work. Vessel needs a working flashlight at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel placed onboard 02 operable lights.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2023 Resolved
46 CFR 182.530 On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual alarms for the machinery and forward space showed the opposite space that they were actuated in. Ensure bilge high level alarm actuates the correct light for the space base on the bilge high level alarm diagram.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Op tested both bilge alarms and were found to be satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 27 June 2023 Resolved
46 CFR 184.506 A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast instructions were post in the machinery room. A copy of the Emergency broadcast instructions needs to be posted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel rep. placed operating instructions near the vessels radio.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2023 Resolved
46 CFR 183.05-35 (b) All lights, receptacles and switches exposed to the weather shall be watertight. An electrical outlet on the outside of the port bulkhead of the machinery space was missing the cover. Outlet cover needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel replaced missing cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 15 November 2022 Resolved
Inspection of radiotelephone installation.Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel did not have a valid Radiotelephony Certificate and is limited to transits no more than 1000 feet from shore. Provide evidence of valid certificate. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 17 November 2022
Resolution: Photo of previously issued cert provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 November 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Engine Room alarm was inoperable. Engine room cover must remain open during ops until repaired to monitor bilge level. Provide evidence of working alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 2 December 2022
Resolution: Conducted facetime video call to verify operation of newly installed engine room bilge alarm. Audiovisual alarms sat, installation viewed & properly configured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 November 2022 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required.(1) Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight casing was cracked. Replace waterlight with approved type and provide evidence.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 29 November 2022
Resolution: Received photo of new floatlight. See docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2022 Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel has not completed an Annual Inspection and is restricted from operating as a passenger vessel beginning 24 July 2022 until a satisfactory Annual Inspection is completed with Sector Mobile.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2022
Resolution: Annual inspection complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 31 March 2021 Resolved
Vessel did not have valid radiotelephony certificate, certificate expired on 8 Mar 2021. Renew certificate. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: Vessel Rep Provided copy of new certificate
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 31 March 2021 Resolved
MSD overboard discharge valve was locked in place with pliers, replace discharge valve to satisfaction of MI. 46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel installed new valve and locked handle
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2021 Resolved
Mast light and anchor light were inoperable. Replace to satisfaction of MI. 33 CFR 83.20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 28 June 2021
Resolution: Vessel rep submitted objective evidence of operational nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021 Resolved
Vessel had multiple life jackets (08) that need new retro reflective tape, 02 life jackets were worn beyond repair and were replaced by deck hand on the spot. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 30 April 2021
Resolution: vessel rep submitted objective evidence clearing def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021 Resolved
Ring buoy grab line was wasted and deteriorated beyond point of repair. Replace buoy with new 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel procured new life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021 Resolved
Floating water light battery expires this month, replace with new. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel procured new waterlight battery.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 March 2021 Resolved
Fire buckets need to be labeled "FIRE BUCKET" in contrasting color. 01 of the buckets was wasted beyond repair. Replace with new. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel got new fire buckets and labeled accordingly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2021 Resolved
Starboard fuel tank piping valve was leaking diesel fuel into bilge. Secure leak to satisfaction of MI prior to carriage of passengers. 46 CFR 182.435
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2021
Resolution: vessel rep provided objective evidence to MI, clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2021 Resolved
Engine shaft seal was leaking at roughly 100 drops per minute, repair to satisfaction of MI prior to carriage of passengers. 46 CFR 182.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2021
Resolution: vessel rep provided objective evidence to MI clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2021 Resolved
Visual indicator on high water alarm was inoperable. 46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 June 2021
Resolution: Vessel rep submitted objective evidence clearing deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020 Resolved
Both P/S float switches for the vessels bilge pumps were inoperable and did not have a positive shutoff valve at the hull penetration. Repair both float switches and install a valve at hull penetration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel repaired both bilge pumps and were observed to be properly operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020 Resolved
Both FWD and AFT bilge alarms were found to be inop. Repair both bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Both bilge alarms were tested and found to be satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020 Resolved
Remote reach rod for bilge suction valve was found to be broke. Repair broken reach rod.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel repaired reach rod for FWD bilge suction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020 Resolved
Vessel is missing a dead eye for the main mast shroud on the STBD side. Replace dead eye for main mast shroud.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel replaced missing deadeye.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2020 Resolved
Stern light, FWD mast head light and anchor light were inoperable. Repair inoperable NAV lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel repaired nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2020 Resolved
Vessel had expired orange smoke signals on board. Replace expired smoke signals.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 21 August 2020
Resolution: Vessel purchased the required smoke signals.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 May 2020 Resolved
Vessel was not properly logging emergency drills. Vessel must properly log drills conducted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 1 June 2020
Resolution: Vessel began utilizing a new checklist for drills and pre departure and has started logging in ships log book.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020 Resolved
Vessel is not maintaining a Preventive Maintenance Plan for the vessels sail rigging. Vessel must establish and maintain a PMP for the vessels sail rigging.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2020
Resolved 30 March 2021
Resolution: Vessel O/O provided updated PMP for sail rigging to satisfaction of attending MI during annual exam.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2020 Resolved
Vessels charts are not up to date. Vessel must provide updated charts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 21 August 2020
Resolution: Vessel purchased second set of charts for the MIKE SEKUL. Vessel is currently swapping charts from one vessel to another until charts come in.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 April 2019 Resolved
Fire boy failed to shutdown generator upon testing. Fire boy override failed to start propulsion engine. Fire boy should shut down all machinery in space and override should be capable of restarting engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2019
Resolution: Vessel had fire servicing company service fire equipment. Vessel demonstrated proper operation of machinery shutdown and overide function for pre-engineered fire fighting system.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 April 2019 Resolved
Donning instructions not posted in donning area. Post life jacket donning instructions for manufacturer of life jacket at donning area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Vessel posted life jacket donning instructions in donning areas
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 April 2019 Resolved
Fire buckets stenciling faded on fire buckets. Stencil "Fire Buckets" on fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Vessel re-stenciled "FIRE BUCKET" on fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2019 Resolved
Water light battery expired. Replace with approved battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Vessel replaced old water light battery with a new one.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 12 April 2019 Resolved
Cable for railing loose. Tighten rail wire cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Rail cabling was tightened to a more appropriate level
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2019 Resolved
Emergency procedures on board are not for the subject vessel. Replace emergency procedures with procedures specfic to the M/V MIKE SEKUL.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Emergency procedures were tailored to the specific vessel and re-posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2019 Resolved
One of two belts missing from bilge pump. Add second belt as per original design.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Two new belts were installed on the bilge pump
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 April 2019 Resolved
Charts for operating area are expired. Update or replace chart of operating area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Old chart was replaced with a new one
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2019 Resolved
Vessel's COI has lapsed and is expired as of 25FEB19. COI exams must be completed every five years prior to the expiration date on the COI. Vessel shall not get underway with passengers until COI exam is completed and new COI is issued. Submit CG-3752 "Application for Inspection of U.S. Vessel" to [email withheld] to apply for new COI and schedule exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2019
Resolution: Completed COI Inspection for vessel and issued Temporary COI until COI is signed and delivered.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2019 Resolved
Vessel has passed fastener pull date required of wood hull passenger vessels every five years IAW NVIC 7-95 Guidance on Inspection, Repair, and Maintenance of Wooden Hulls. Vessel shall be hauled out of the water and made available for fastener pull at time of COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 10 April 2019
Resolution: Completed wood hull fastener pull and keel bolt inspection.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 April 2017 Resolved
Conduct and document completion of fire, man overboard and abandon ship drills IAW 46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Drills logged accordingly.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 April 2017 Resolved
Provide proof of supervisory and crew training for drug and alcohol program, carry policy on board and post EAP number conspicuous location IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Proof of supervisory training provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2017 Resolved
Repair or replace running light IAW 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Running light operational.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 April 2017 Resolved
Repair or replace float switches IAW 46 CFR 182.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Float switches operational.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 April 2017 Resolved
Label bilge pump alarm panel with appropriate compartment names and locations IAW 46 CFR 182.530
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Alarm panel labeled.
Fire Fighting › Fire Bucket › Stenciling
Issued 19 April 2017 Resolved
Properly label fire buckets IAW 46 CFR 181.610
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Fire buckets labeled.
Documentation › Logs/Records › Logbook (official)
Issued 7 April 2016 Resolved
Drills and radio logs must be up-to-date. Log all drills and radio test in accordance with 46CFR 185.524/185.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Updated drills and logs
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 April 2016 Resolved
The vessel must have current charts and navigational publications in accordance with 46 CFR 184.420. Update vessels charts and publication publications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Obtained new charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 April 2016 Resolved
First aid kit was out of date. Update first aid kit in accordance with 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Replaced expired medicine
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 April 2016 Resolved
Expired consortium documentation. Provide updated consortium letter, employee assistance program, and verify training of designated testing crewmember in accordance with 46 CFR 185, 46 CFR 16.401, and 46 CFR 4.06-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 13 June 2016
Resolution: Received correspondence from Owner/Operator of updated consortium letter.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 April 2016 Resolved
Broken water light on life ring. Replace or repair in accordance with 46 CFR 180.70(d). Vessel restricted to daylight operations only.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 14 April 2016
Resolution: Replaced light
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 April 2016 Resolved
Electrical outlet is missing cover. Repair or replace in accordance with46 CFR 183.220.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Installed cover.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 April 2016 Resolved
Bilge light is not visible from operating station. Make bilge light visible in accordance with 46 CFR 182.530
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Installed bilge light.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 7 April 2016 Resolved
- Deployment of fireboy must shut off the generator. Fireboy does not shut off generator, repair in accordance with 46 CFR 181.420. Secure generator until fixed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Fireboy shut off generator.
Fire Fighting › Fire Bucket › Availability
Issued 7 April 2016 Resolved
Fire buckets are not on board; correct in accordance with 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 14 April 2016
Resolution: Vessel added 3 fire buckets.
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2016 Resolved
Condition of life ring is not satisfactory. Replace life ring in accordance with 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Replaced life ring.
Sail Rigging › Running Rigging › Topping Lifts/Attachments
Issued 7 April 2016 Resolved
Sail rigging report not readily available. Needs to email or send copy of last rigging survey completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 27 September 2016
Resolution: Rigging survey completed and recommendations are being done.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 February 2016 Resolved
Vessel does not possess valid FCC Safety Radio Telephony Certificate. Provide proof of valid certificate to attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Received copy of FCC Safety Radio Telephony Certificate and uploaded it to Certs.

Ownership record