Records from 1993 to 2026. Most recent: inspection, 17 July 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 78
17 July 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8437181
9 February 2026
Drydock Exam · Hull Examination · Vessel Attendance · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8308107
3 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8087617
15 April 2024
In-Service Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7895634
5 January 2024
Hull Examination · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7845570
27 June 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7725102
15 November 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7594544
3 January 2022
Examination of Repairs · Administrative Inspection · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7374917
31 March 2021
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7166124
6 May 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6949311
7 January 2020
Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6885356
9 April 2019
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6659053
28 March 2019
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6651391
8 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6368673
26 January 2018
Examination of Repairs · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6344161
19 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6153312
19 April 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6128591
3 March 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6098510
26 September 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6010035
18 May 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5881170
14 April 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5854500
31 March 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5844344
14 March 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5833203
21 January 2016
Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5801352
10 March 2014
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4811848
20 October 2008
Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3348276
1 August 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3276552
2 July 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3252564
28 March 2008
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167104
29 November 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3099562
18 October 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3082259
6 September 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3050526
1 August 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2719385
5 July 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2701795
4 May 2006
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2640192
25 April 2005
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2342372
10 September 2004
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2192485
27 May 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2079679
27 February 2004
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2000397
19 August 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1887350
5 August 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1867471
5 June 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1792482
28 March 2003
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1764342
8 January 2003
Deficiency Check · Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1727022
20 March 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1477989
21 August 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1071642
21 June 2001
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1068660
24 July 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821317
20 June 2000
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1052212
24 March 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1441638
8 July 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1423215
1 December 1998
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032899
12 August 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1131115
30 June 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1127113
22 June 1998
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1126301
24 April 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1402664
23 April 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 669540
24 March 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 789933
24 March 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1414977
24 March 1998
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1446627
16 October 1997
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1111383
27 August 1997
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1120976
31 July 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 781482
24 June 1997
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364217
16 August 1996
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1095517
25 June 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1357653
14 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380457
29 June 1995
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1400211
10 November 1994
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 835670
15 September 1994
Plan Review "T" Boat · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1181414
9 August 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 675187
19 July 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1174376
17 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 18323
30 June 1994
Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172295
30 June 1994
Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1173174
23 June 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1382793
8 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172140
22 October 1993
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861994
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 April 2024
Resolved
a vessel must carry adequate
and up-to-date:
(1) Charts of large enough scale to
make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List;
(4) Tide tables; and
(5) Current tables
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 4 June 2024
Resolution: Vessel downloaded electronic versions of all charts and pubs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Vessel had a breathalizer that was not calibrated per manufacturers instructions.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 4 June 2024
Resolution: Vessel purchased new alcohol testing strips.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 June 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here: Certification or licensing by a state or local jurisdiction as a fire extinguisher servicing agency will be accepted by the Coast Guard as meeting the personnel certification requirements of NFPA 10 for annual maintenance and recharging of extinguishers. Vessel has the annual servicing sticker but did not have the annual servicing paperwork. Vessel needs to provide annual servicing paperwork.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 5 July 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 June 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel’s stern light is inoperable. Vessel needs to fix stern light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel replaced stern nav light.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 June 2023
Resolved
46 CFR 183.430
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Portable light at the operating station did not work. Vessel needs a working flashlight at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel placed onboard 02 operable lights.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2023
Resolved
46 CFR 182.530
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The visual alarms for the machinery and forward space showed the opposite space that they were actuated in. Ensure bilge high level alarm actuates the correct light for the space base on the bilge high level alarm diagram.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Op tested both bilge alarms and were found to be satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 27 June 2023
Resolved
46 CFR 184.506
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast instructions were post in the machinery room. A copy of the Emergency broadcast instructions needs to be posted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel rep. placed operating instructions near the vessels radio.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 June 2023
Resolved
46 CFR 183.05-35 (b)
All lights, receptacles and switches exposed to the weather shall be watertight. An electrical outlet on the outside of the port bulkhead of the machinery space was missing the cover. Outlet cover needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2023
Resolved 10 July 2023
Resolution: Vessel replaced missing cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 15 November 2022
Resolved
Inspection of radiotelephone installation.Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Vessel did not have a valid Radiotelephony Certificate and is limited to transits no more than 1000 feet from shore. Provide evidence of valid certificate.
47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 17 November 2022
Resolution: Photo of previously issued cert provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 November 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Engine Room alarm was inoperable. Engine room cover must remain open during ops until repaired to monitor bilge level. Provide evidence of working alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 2 December 2022
Resolution: Conducted facetime video call to verify operation of newly installed engine room bilge alarm. Audiovisual alarms sat, installation viewed & properly configured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 November 2022
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required.(1) Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight casing was cracked. Replace waterlight with approved type and provide evidence.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2022
Resolved 29 November 2022
Resolution: Received photo of new floatlight. See docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 July 2022
Resolved
Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel has not completed an Annual Inspection and is restricted from operating as a passenger vessel beginning 24 July 2022 until a satisfactory Annual Inspection is completed with Sector Mobile.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2022
Resolution: Annual inspection complete.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 31 March 2021
Resolved
Vessel did not have valid radiotelephony certificate, certificate expired on 8 Mar 2021. Renew certificate.
47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: Vessel Rep Provided copy of new certificate
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 31 March 2021
Resolved
MSD overboard discharge valve was locked in place with pliers, replace discharge valve to satisfaction of MI.
46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel installed new valve and locked handle
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 March 2021
Resolved
Mast light and anchor light were inoperable. Replace to satisfaction of MI.
33 CFR 83.20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 28 June 2021
Resolution: Vessel rep submitted objective evidence of operational nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021
Resolved
Vessel had multiple life jackets (08) that need new retro reflective tape, 02 life jackets were worn beyond repair and were replaced by deck hand on the spot.
46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 30 April 2021
Resolution: vessel rep submitted objective evidence clearing def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021
Resolved
Ring buoy grab line was wasted and deteriorated beyond point of repair. Replace buoy with new
46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel procured new life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021
Resolved
Floating water light battery expires this month, replace with new.
46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel procured new waterlight battery.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 March 2021
Resolved
Fire buckets need to be labeled "FIRE BUCKET" in contrasting color. 01 of the buckets was wasted beyond repair. Replace with new.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 26 April 2021
Resolution: vessel got new fire buckets and labeled accordingly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2021
Resolved
Starboard fuel tank piping valve was leaking diesel fuel into bilge. Secure leak to satisfaction of MI prior to carriage of passengers.
46 CFR 182.435
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2021
Resolution: vessel rep provided objective evidence to MI, clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2021
Resolved
Engine shaft seal was leaking at roughly 100 drops per minute, repair to satisfaction of MI prior to carriage of passengers.
46 CFR 182.200
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 April 2021
Resolution: vessel rep provided objective evidence to MI clearing def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2021
Resolved
Visual indicator on high water alarm was inoperable.
46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 2 June 2021
Resolution: Vessel rep submitted objective evidence clearing deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020
Resolved
Both P/S float switches for the vessels bilge pumps were inoperable and did not have a positive shutoff valve at the hull penetration. Repair both float switches and install a valve at hull penetration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel repaired both bilge pumps and were observed to be properly operating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020
Resolved
Both FWD and AFT bilge alarms were found to be inop. Repair both bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Both bilge alarms were tested and found to be satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020
Resolved
Remote reach rod for bilge suction valve was found to be broke. Repair broken reach rod.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel repaired reach rod for FWD bilge suction.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020
Resolved
Vessel is missing a dead eye for the main mast shroud on the STBD side. Replace dead eye for main mast shroud.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel replaced missing deadeye.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 May 2020
Resolved
Stern light, FWD mast head light and anchor light were inoperable. Repair inoperable NAV lights.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2020
Resolved 10 June 2020
Resolution: Vessel repaired nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2020
Resolved
Vessel had expired orange smoke signals on board. Replace expired smoke signals.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 21 August 2020
Resolution: Vessel purchased the required smoke signals.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 May 2020
Resolved
Vessel was not properly logging emergency drills. Vessel must properly log drills conducted.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 1 June 2020
Resolution: Vessel began utilizing a new checklist for drills and pre departure and has started logging in ships log book.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020
Resolved
Vessel is not maintaining a Preventive Maintenance Plan for the vessels sail rigging. Vessel must establish and maintain a PMP for the vessels sail rigging.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2020
Resolved 30 March 2021
Resolution: Vessel O/O provided updated PMP for sail rigging to satisfaction of attending MI during annual exam.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 May 2020
Resolved
Vessels charts are not up to date. Vessel must provide updated charts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2020
Resolved 21 August 2020
Resolution: Vessel purchased second set of charts for the MIKE SEKUL. Vessel is currently swapping charts from one vessel to another until charts come in.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 12 April 2019
Resolved
Fire boy failed to shutdown generator upon testing. Fire boy override failed to start propulsion engine. Fire boy should shut down all machinery in space and override should be capable of restarting engines.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2019
Resolution: Vessel had fire servicing company service fire equipment. Vessel demonstrated proper operation of machinery shutdown and overide function for pre-engineered fire fighting system.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 April 2019
Resolved
Donning instructions not posted in donning area. Post life jacket donning instructions for manufacturer of life jacket at donning area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Vessel posted life jacket donning instructions in donning areas
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 April 2019
Resolved
Fire buckets stenciling faded on fire buckets. Stencil "Fire Buckets" on fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Vessel re-stenciled "FIRE BUCKET" on fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 April 2019
Resolved
Water light battery expired. Replace with approved battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Vessel replaced old water light battery with a new one.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 12 April 2019
Resolved
Cable for railing loose. Tighten rail wire cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Rail cabling was tightened to a more appropriate level
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2019
Resolved
Emergency procedures on board are not for the subject vessel. Replace emergency procedures with procedures specfic to the M/V MIKE SEKUL.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Emergency procedures were tailored to the specific vessel and re-posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2019
Resolved
One of two belts missing from bilge pump. Add second belt as per original design.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Two new belts were installed on the bilge pump
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 April 2019
Resolved
Charts for operating area are expired. Update or replace chart of operating area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 23 April 2019
Resolution: Old chart was replaced with a new one
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2019
Resolved
Vessel's COI has lapsed and is expired as of 25FEB19. COI exams must be completed every five years prior to the expiration date on the COI. Vessel shall not get underway with passengers until COI exam is completed and new COI is issued. Submit CG-3752 "Application for Inspection of U.S. Vessel" to [email withheld] to apply for new COI and schedule exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2019
Resolution: Completed COI Inspection for vessel and issued Temporary COI until COI is signed and delivered.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2019
Resolved
Vessel has passed fastener pull date required of wood hull passenger vessels every five years IAW NVIC 7-95 Guidance on Inspection, Repair, and Maintenance of Wooden Hulls. Vessel shall be hauled out of the water and made available for fastener pull at time of COI inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 April 2019
Resolved 10 April 2019
Resolution: Completed wood hull fastener pull and keel bolt inspection.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 April 2017
Resolved
Conduct and document completion of fire, man overboard and abandon ship drills IAW 46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Drills logged accordingly.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 19 April 2017
Resolved
Provide proof of supervisory and crew training for drug and alcohol program, carry policy on board and post EAP number conspicuous location IAW 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Proof of supervisory training provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2017
Resolved
Repair or replace running light IAW 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Running light operational.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 April 2017
Resolved
Repair or replace float switches IAW 46 CFR 182.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Float switches operational.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 April 2017
Resolved
Label bilge pump alarm panel with appropriate compartment names and locations IAW 46 CFR 182.530
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Alarm panel labeled.
Fire Fighting › Fire Bucket › Stenciling
Issued 19 April 2017
Resolved
Properly label fire buckets IAW 46 CFR 181.610
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Resolution: Fire buckets labeled.
Documentation › Logs/Records › Logbook (official)
Issued 7 April 2016
Resolved
Drills and radio logs must be up-to-date. Log all drills and radio test in accordance with 46CFR 185.524/185.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Updated drills and logs
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 April 2016
Resolved
The vessel must have current charts and navigational publications in accordance with 46 CFR 184.420. Update vessels charts and publication publications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Obtained new charts.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 April 2016
Resolved
First aid kit was out of date. Update first aid kit in accordance with 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Replaced expired medicine
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 April 2016
Resolved
Expired consortium documentation. Provide updated consortium letter, employee assistance program, and verify training of designated testing crewmember in accordance with 46 CFR 185, 46 CFR 16.401, and 46 CFR 4.06-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 13 June 2016
Resolution: Received correspondence from Owner/Operator of updated consortium letter.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 April 2016
Resolved
Broken water light on life ring. Replace or repair in accordance with 46 CFR 180.70(d). Vessel restricted to daylight operations only.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 14 April 2016
Resolution: Replaced light
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 April 2016
Resolved
Electrical outlet is missing cover. Repair or replace in accordance with46 CFR 183.220.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Installed cover.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 April 2016
Resolved
Bilge light is not visible from operating station. Make bilge light visible in accordance with 46 CFR 182.530
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Installed bilge light.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 7 April 2016
Resolved
- Deployment of fireboy must shut off the generator. Fireboy does not shut off generator, repair in accordance with 46 CFR 181.420. Secure generator until fixed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Fireboy shut off generator.
Fire Fighting › Fire Bucket › Availability
Issued 7 April 2016
Resolved
Fire buckets are not on board; correct in accordance with 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 14 April 2016
Resolution: Vessel added 3 fire buckets.
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2016
Resolved
Condition of life ring is not satisfactory. Replace life ring in accordance with 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 18 May 2016
Resolution: Replaced life ring.
Sail Rigging › Running Rigging › Topping Lifts/Attachments
Issued 7 April 2016
Resolved
Sail rigging report not readily available. Needs to email or send copy of last rigging survey completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2016
Resolved 27 September 2016
Resolution: Rigging survey completed and recommendations are being done.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 29 February 2016
Resolved
Vessel does not possess valid FCC Safety Radio Telephony Certificate. Provide proof of valid certificate to attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Received copy of FCC Safety Radio Telephony Certificate and uploaded it to Certs.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 July 2008
Resolved
Replace all expired medication in first aid kit.
Due 2 August 2008
Resolved 1 August 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 July 2008
Resolved
Place lifejacket placard on starboard aft storage locker.
Due 2 August 2008
Resolved 1 August 2008
Electrical › Electric Generation Source (service) › Generator
Issued 2 July 2008
Resolved
Prove proper operation of the ships service generator.
Due 2 August 2008
Resolved 1 August 2008
Electrical › Electric Generation Source (service) › Generator
Issued 2 July 2008
Resolved
Prove ambient temperature and amperage of ships service generator.
Due 2 August 2008
Resolved 1 August 2008
Construction/Loadline › Hull › Stiffener
Issued 2 July 2008
Resolved
Provide and install proper bolts in shaft log packing gland to allow for double nutting.
Due 2 August 2008
Resolved 1 August 2008
Engineering › Bilge Water Management System › Piping
Issued 2 July 2008
Resolved
Make repairs to leaking bilge manifold, bilge pump, and piping.
Due 2 August 2008
Resolved 1 August 2008
Construction/Loadline › Hull › Keel
Issued 28 March 2008
Resolved
Submit repair proposals for rotten area in way of the stem as per 46 CFR 176.800.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2008
Resolution: Repair proposals have been submitted and approved.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2008
Resolved
Repair all rotten areas marked on the cover board and throughout the vessel as per 46 CFR 176.800.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2008
Resolution: All rotten areas have been properly repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 March 2008
Resolved
Properly repair the main engine exhaust leak under the forward rubber hose as per 46 CFR 176.800.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2008
Resolution: A new stainless steel sleeve/collar was fabricated and installed.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2008
Resolved
Repair the worm holes around the starboard aft hull penetration as per 46 CFR 176.800.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2008
Resolution: The plank containing the worm holes has been replaced.
Documentation › Logs/Records › Logbook (official)
Issued 5 July 2006
Resolved
Provide a current training log book, a life saving equipment maintenance record and a current bridge log in accordance with 46 CFR 185.702.
Due 5 August 2006
Resolved 1 August 2006
Resolution: Provided a current training log book, a life saving equipment maintenance record and a current bridge log in accordance with 46 CFR 185.702.
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2006
Resolved
Provide a current tidal current table and updated charts of the area of operations in accordance with 46CFR 184.420
Due 5 August 2006
Resolved 1 August 2006
Resolution: Provided a current tidal current table and updated charts of the area of operation in accordance with 46 CFR 184.420.
Lifesaving › Lifebuoys › Serviceable
Issued 5 July 2006
Resolved
Properly attach the water light to the ring life buoy in accordance with 46 CFR 180.70
Due 5 August 2006
Resolved 1 August 2006
Resolution: Properly attached the water light to the life ring in accordance with 46 CFR 180.70.
Communications › Radio Communications › EPIRB
Issued 5 July 2006
Resolved
Provide a hydrostatic release for the EPIRB in accordance with 46 CFR 185.728. The vessel is restricted to within 3 miles from shore until the release is installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2006
Resolved 1 August 2006
Resolution: Provided a hydrostatic release for the EPIRB in accordance with 46 CFR 185.728.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 5 July 2006
Resolved
Provide and install retro reflective tape on the lifejackets as needed in accordance with 46 CFR 185.604.
Due 5 August 2006
Resolved 1 August 2006
Resolution: Provided and installed retro reflective tape on the lifejackets as needed in accordance with 46 CFR 185.604.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2006
Resolved
Provide a coast guard approved first aid kit or its equivalent in accordance with 46 CFR184.710.
Due 5 August 2006
Resolved 1 August 2006
Resolution: Provided a Coast Guard approved first aid kit or its equivalent with 46 CFR 184.710.
Engineering › Bilge Water Management System › Pump
Issued 5 July 2006
Resolved
Provide and install machinery guard's over rotating machinery for the bilge pump in accordance with 46 CFR 177.960.
Due 5 August 2006
Resolved 1 August 2006
Resolution: Provided and installed machinery guard''s over rotating machinery for the bilge pump in accordance with 46 CFR 177.960.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 July 2006
Resolved
Properly label electrical distribution panel in accordance with 46 CFR 183.330.
Due 5 August 2006
Resolved 1 August 2006
Resolution: Properly labeled electrical distribution panel in accordance with 46 CFR 183.330.
Electrical › Electric Supply System (service) › Cable
Issued 5 July 2006
Resolved
Properly support all electrical wiring in the engine room in accordance with 46 CFR 183.340.
Due 5 August 2006
Resolved 1 August 2006
Resolution: Properly supported all electrical wiring in the engine room in accordance with 46 CFR 183.340.
Construction/Loadline › Hull › Side Shell
Issued 4 May 2006
Resolved
Provide repair proposal for rotten planks on the port and starboard side IWO the stem.
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 14 June 2006
Resolution: Received a verbal repair proposal.
Construction/Loadline › Hull › Side Shell
Issued 4 May 2006
Resolved
Provide repair proposal for rotten planks top of the hull on the port and starboard side amidships.
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 14 June 2006
Resolution: Received a verbal proposal.
Construction/Loadline › Hull › Hull Plating
Issued 4 May 2006
Resolved
Make repairs to the deteriorated wood planks, the stem and #2 frame on the starboard side.
Due 4 June 2006
Resolved 14 June 2006
Resolution: Repairs were made to the hull planking, the stem and #2 frame. The Planking was replaced back to the first butt block, a portion of the stem was removed/scarffed out and replace and the#2 frame was total replaced.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 4 August 2004
Resolved
Fixed firefighting had not been serviced IAW 46 CFR 181.410.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 5 August 2004
Resolution: Faxed reciept from servicing company.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 August 2004
Resolved
Need to submit repair proposal for minor rotting at the thru-hull fitting for the exhaust coolant bypass IAW 46 CFR 179.350.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 10 September 2004
Resolution: Received repair proposal. Approved proposal and sent approval letter to owner. Vessel must complete repairs at next drydock prior to 30APR2004.
Engineering › Bilge Water Management System › Piping
Issued 27 May 2004
Resolved
Bilge piping system not operating IAW 46 CFR 182.510.
Action required: 705 - Other - as specified
Due 9 August 2004
Resolved 4 August 2004
Resolution: Repaired broken pipe in bilge piping system.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 27 February 2004
Resolved
Repair/Replace the non structural floor frames (2x4's) that support plywood deck plates.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2004
Resolved 2 March 2004
Resolution: The floor framing was replaced in kind.
Operations/Management
Issued 27 February 2004
Resolved
Make engine room and forward cabin bilges clean and dry.
Action required: 705 - Other - as specified
Due 2 March 2004
Resolved 2 March 2004
Resolution: Bilges were cleaned and dried and appeared to be in satisfactory condition.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 June 2003
Resolved
Tighten all loose rail coursings around vessel gunwale as required by 46 CFR 177.900. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 3 August 2003
Resolved 19 August 2003
Resolution: Coursings were tightened on the entire perimeter of the vessel.
Construction/Loadline › Structures
Issued 5 June 2003
Resolved
Repair three foot tear at top of mainsail as required by 46 CFR 177.330. LEGACY COMPONENT DESC: Mainsail
Condition: Damaged By Earlier Event
Due 3 August 2003
Resolved 8 July 2003
Fire Fighting › Miscellaneous Items
Issued 5 June 2003
Resolved
Replace wasted/holed fire buckets as required by 46 CFR 181.610. LEGACY COMPONENT DESC: Fire Buckets
Condition: Improper/Lack of Maintenance
Due 13 July 2003
Resolved 19 August 2003
Resolution: Replaced the wasted buckets with 2.5 gallon metal buckets marked "Fire Bucket."
Engineering › Fuel Oil Storage/Transfer System
Issued 5 June 2003
Resolved
Provide solid bottom plug on fuel filter for generator as required by 46 CFR 182.455. LEGACY COMPONENT DESC: Filter/Strainer
Condition: Improper/Lack of Maintenance
Due 3 August 2003
Resolved 19 August 2003
Resolution: Bottom plug installed on fuel filter to generator.
Engineering › Bilge Water Management System
Issued 5 June 2003
Resolved
Replace inoperative bilge pump switch near stuffing box near MDE as required by 46 CFR 182.520. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 13 July 2003
Resolved 19 August 2003
Resolution: Replaced bilge switch near stuffing box for MDE.
Personnel › Manning/Qualifications
Issued 5 June 2003
Resolved
Provide proof of crew first aid cards as required by NVIC 1-91. LEGACY COMPONENT DESC: First Aid Certified Personnel
Condition: Unknown
Due 3 August 2003
Resolved 8 July 2003
Lifesaving › Lifebuoys
Issued 5 June 2003
Resolved
Replace sun rotted lifeline on ring buoy as required by 46 CFR 181.30. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 3 August 2003
Resolved 19 August 2003
Resolution: Completely renewed lifeline on ring buoy.
Construction/Loadline › Hull
Issued 11 January 2002
Resolved
Provide repair propsal for planking repair/replacement as marked where decayed. LEGACY COMPONENT DESC: Planking
Due 20 March 2002
Resolved 20 March 2002
Resolution: Provided repair /replacement proposal for all decayed wood.
Construction/Loadline › Structures › Superstructure
Issued 11 January 2002
Resolved
Provide repair proposal for cabin wood decay. Not to exclude main deck along port side aft.
Due 20 March 2002
Resolved 20 March 2002
Resolution: Provided verbal repair proposal.
Construction/Loadline › Hull › Keel
Issued 11 January 2002
Resolved
Provide repair proposal for wood rot located on keel in way of garboard strake port and starboard side aft.
Due 20 March 2002
Resolved 20 March 2002
Resolution: Porvided verbal repair proposal.
Construction/Loadline › Structures › Ventilators
Issued 11 January 2002
Resolved
Provide improved ventilation in forpeak do to excessive fungas growth.
Due 20 March 2002
Resolved 20 March 2002
Resolution: Installed two ventilation cowls.
Construction/Loadline › Penetrations
Issued 11 January 2002
Resolved
Open all sea valves for inspection. LEGACY COMPONENT DESC: Sea valves
Due 20 March 2002
Resolved 19 March 2002
Resolution: Inspected all sea valves.
Engineering
Issued 21 June 2001
Resolved
MAKE PROPER REPAIRS TO HEAT EXCHANGER EXHAUST PIPE AS REQUIRED BY 46 CFR 176.830., PRIOR TO USING SHIPS SERVICE GENERATOR. REPAIRS SHALL BE MADE TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 June 2001
Resolved 21 June 2001
Electrical
Issued 20 June 2000
Resolved
PROVIDE PROTECTIVE ENCLOSURE FOR THE MSD WIRING AS REQUIRED BY 46 CFR 183.200.
Condition: Unknown
Due 20 July 2000
Resolved 28 July 2000
Accommodation/Occupational Safety
Issued 20 June 2000
Resolved
PROVIDE ACCESS FOR GENERATOR SEA SUCTION VALVE AS REQUIRED BY 46 CFR 176.804.
Condition: Unknown
Due 20 July 2000
Resolved 28 July 2000
Fire Fighting
Issued 20 June 2000
Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE PROPER SERVICING OF FIXED FIRE_x001C_ FIGHTING SYSTEM AS REQUIRED BY 46 CFR 176.810(b).
Condition: Unknown
Due 27 June 2000
Resolved 28 July 2000
Accommodation/Occupational Safety
Issued 20 June 2000
Resolved
PROVIDE PROPER RAIL COURSES AS REQUIRED BY 46 CFR 177.900.
Condition: Unknown
Due 20 July 2000
Resolved 28 July 2000
Documentation
Issued 20 June 2000
Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE AS REQUIRED BY 47 CFR 80.903.
Condition: Unknown
Due 20 July 2000
Resolved 28 July 2000
Documentation
Issued 24 March 1998
Resolved
VESSEL'S OWNER/OPERATOR TO PAY REQUIRED ANNUAL VESSEL INSPECION FEE IN ACCORDANCE WITH 46 CFR 2.10-20.
Condition: Unknown
Due 24 March 1998
Resolved 30 June 1998
Construction/Loadline
Issued 24 March 1998
Resolved
PROPERLY REPAIR ROTTED GARBOARD PLANK PORT SIDE AFT. NVIC 7-95.
Condition: Unknown
Due 24 March 1998
Resolved 10 April 1998
Construction/Loadline
Issued 24 March 1998
Resolved
PROPERLY REPAIR ROTTED AREA ON STARBOARD SIDE OF THE KEEL. NVIC 7-95.
Condition: Unknown
Due 24 March 1998
Resolved 10 April 1998
Construction/Loadline
Issued 24 March 1998
Resolved
PROPERLY REPAIR FRACTURED PLANK STARBOARD SIDE NEAR THE STEM. NVIC 7-95
Condition: Unknown
Due 24 March 1998
Resolved 10 April 1998
Navigation
Issued 24 March 1998
Resolved
PROVIDE UP TO DATE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH 46 CFR 184.420.
Condition: Unknown
Due 24 April 1998
Resolved 27 April 1998
Lifesaving
Issued 24 March 1998
Resolved
RENEW WASTED COTTON DRAW TIE STRAPS ON 22 EXTENDED SIZE PFD'S SEE 46 CFR 160.055.
Condition: Unknown
Due 24 April 1998
Resolved 27 April 1998
Electrical
Issued 24 March 1998
Resolved
PROVIDE A MANUFACTURES DATA PLACARD FOR THE GENERATOR SHOWING THE AMBIENT AIR TEMPERATURE RATING OF THE DEVICE IN ACCORDANCE WITH 46 CFR 183.10-5.
Condition: Unknown
Due 24 April 1998
Resolved 27 April 1998
Navigation
Issued 24 March 1998
Resolved
PROVIDE AND POST AN EMERGENCY BROADCAST PLACARD IN ACCORDANCE WITH 46 CFR 184.506.
Condition: Unknown
Due 24 April 1998
Resolved 27 April 1998
Construction/Loadline
Issued 24 June 1997
Resolved
PROVIDE AND PROPERLY INSTALL A METALIC VALVE IN THE COLLISION BULKHEAD BILGE LINE BETWEEN THE PVC PIPING AND THE METALIC BULKHEAD PENETRATION ON THE AFT SIDE OF THE BULKHEAD IAW 46 CFR 182.40-1
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Electrical
Issued 24 June 1997
Resolved
PROVIDE AND PROPERLY INSTALL GROUND WIRES ON ALL METAL THROUGH HULL FITTINGS TO INCLUDE THE MAIN ENGINE AND SHAFT LOG IAW COAST GUARD NVIC 7-95CHAPTER 4, PARAGRAPH 5-H.
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Lifesaving
Issued 24 June 1997
Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT OR ALL ITEMS REQUIRED BY 160.041 IAW 46 CFR 184.710
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Accommodation/Occupational Safety
Issued 24 June 1997
Resolved
PROVIDE AND PROPERLY POST A SIGNED WASTE MANAGEMENT PLAN IAW 33 CFR 151.57
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Lifesaving
Issued 24 June 1997
Resolved
PROVIDE 15 EXTENDED SIZE LIFE JACKETS TO ACCOMMODATE THE NUMBER OF PERSONS AS LISTED ON THE COI IAW 46 CFR 180.71(a). PROVIDE 3 CHILD SIZE LIFE JACKETS IAW 46 CFR 180.71 (b)(2)._x001C_
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Lifesaving
Issued 24 June 1997
Resolved
PROVIDE A 3 FOOT LANYARD FOR THE WATERLIGHT ON THE LIFE RING BUOY IAW 46 CFR 180.70(d).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 24 June 1997
Resolved
PROPERLY ATTATCH THE FORWARD HATCH COVER LANYARD IAW 46 CFR 171.124(a)(1).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Fire Fighting
Issued 24 June 1997
Resolved
PROVE THAT THE PORTABLE FIRE EXTINGUISHERS HAVE BEEN PROPERLY SERVICED IAW 46 CFR 178.810.
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Electrical
Issued 24 June 1997
Resolved
PROPERLY GROUND THE INDEPENDENT FUEL TANKS IAW 46 CFR 182.20-25(b)(4).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Documentation
Issued 24 June 1997
Resolved
CONDUCT DEAD WEIGHT SURVEY AND SEND RESULTS TO COAST GUARD HEADQUARTERS MSC-1 IAW 46 CFR 170.170 AND 171.055.
Condition: Unknown
Due 24 July 1997
Resolved 27 August 1997
Engineering
Issued 24 June 1997
Resolved
PROVE PROPER OPERATION OF THE ENGINE TACHOMETER IAW 46 CFR 182.410(b).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Engineering
Issued 24 June 1997
Resolved
PROVIDE AND PROPERLY INSTALL A FUEL SHUT OFF VALVE AT THE ENGINE END OF THEFUEL LINE IAW 46 CFR 182.20-40(b)(3) AND REMOVE THE PETCOCK FROM THE FUEL FILTER HOUSING IAW 46 CFR 182.20-40(a)(4).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Documentation
Issued 24 June 1997
Resolved
PROVIDE ELECTRICAL DRAWINGS OF THE NEW GENERATOR INSTALLATION TO MSO MOBILEFOR REVIEW AND APPROVAL IAW 46 CFR 177.202(b)(4)
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Documentation
Issued 24 June 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Electrical
Issued 24 June 1997
Resolved
EACH NONMETTALIC MAST AND TOP MAST MUST HAVE A LIGHTNING GROUND CONDUCTOR IAW 46 CFR 183.370(c)
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Lifesaving
Issued 24 June 1997
Resolved
PROVIDE AND INSTALL A PROPER SIZED FLOAT FREE LINK FOR THE LIFEFLOAT IAW 46CFR 180.130(a)(1).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Electrical
Issued 24 June 1997
Resolved
PROVE PROPER OPERATION OF THE GENERATOR AND ALL METERS IAW 46 CFR 176.806(e) AND 46 CFR 183.320(c).
Condition: Unknown
Due 24 June 1997
Resolved 24 June 1997
Deck/Cargo
Issued 24 June 1997
Resolved
PROVIDE THE PROPER SIZED ANCHOR IAW CID MEMO 1.10.
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Accommodation/Occupational Safety
Issued 24 June 1997
Resolved
PROPERLY INSTALL A VENT LINE FROM THE MSD TANK TO THE ATMOSPHERE WITH A 30x30 MESH SCREEN IAW 33 CFR 159.95(a)(2).
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Electrical
Issued 24 June 1997
Resolved
PROVIDE AND INSTALL METAL WIRE SUPPORTS EVERY 24" IAW 46 CFR 183.340(b)(4)
Condition: Unknown
Due 24 July 1997
Resolved 31 July 1997
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE AND POST EMERGENCY INSTRUCTION PLACARD IAW 46CFR 185.512. NLT 25JUL96
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Fire Fighting
Issued 25 June 1996
Resolved
PROVIDE PROPER BRACKET FOR B-I FIRE EXTINGUISHER MOUNTED ON STEERING CONSOLE. NLT 25JUL96
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Accommodation/Occupational Safety
Issued 25 June 1996
Resolved
PROVIDE AND MOUNT WASTE MANAGEMENT PLAN IAW 33 CFR 159.57 NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE 2 PADDLES 4' IN LENGTH ATTACHED TO LIFEFLOAT IAW 46CFR 180.175. NLT25JUL96
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 25 June 1996
Resolved
PROPERLY MARK REMOTE FUEL SHUTOFF VALVES IAW 46CFR 182.455(b)(4) NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE PROPER BRACKET FOR LIFEFLOAT WATERLIGHT NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 25 June 1996
Resolved
PROVIDE AND INSTALL APPROVED FUEL HOSES FROM FILTER SEPERATOR TO MAIN ENGINE TO MEET SAE J-1942 WITH FACTORY FITTINGS IAW 46CFR 182.720 NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE AND POST LIFE JACKET DONNING INSTRUCTIONS IAW 46CFR 185.516. NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE EVIDENCE THAT REQUIRED CREW TRAINING UPON EMPLOYMENT AND QUARTERLY IS CONDUCTED IAW 46CFR 185.420(a), 185.520, 185.524.NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE PORTABLE WATERTIGHT CONTAINER FOR DISTRESS SIGNALS IAW 46CFR 185.614
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROVIDE AND INSTALL RETROREFLECTIVE TAPE ON RING BOUYS IAW 46CFR 185.640(H)NLT 25JUL96
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROPERLY MARK LIFEJACKET LOCKERS WITH CONTENTS IAW 46CFR 180.78(A) NLT 25JUL96
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
PROPERLY STOW LIFEFLOAT TO ALLOW FOR FLOAT FREE ARRANGHEMENT IAW 46CFR 180.130 (a)(2)(3) NLT 25JUL96
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Lifesaving
Issued 25 June 1996
Resolved
EQUIP LIFEFLOAT WITH 100' SEA PAINTER AND WEAK LINK IAW 46CFR 180.175 NLT 25JUL96.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 25 June 1996
Resolved
PROVIDE AND INSTALL ELECTRICALLY CONDUCTIVE MATERIAL BETWEEN FUEL FILL AND FUEL TANK WHERE RUBBER HOSE MAKES CONNECTION TO PROTECT AGAINST STATIC ELECTRICITY DISCHARGE IAW 46CFR 182.455(g).
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 29 June 1995
Resolved
RELOCATE FUEL OIL REMOTE SHUT OFF REACH RODS OUTSIDE OF THE FUEL OIL TANK COMPARTMENT.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Documentation
Issued 30 June 1994
Resolved
PROVIDE APPROVED PLANS OF THE 110V ELECTRICAL SYSTEM. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATER THAN 30 JUL 94.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Documentation
Issued 30 June 1994
Resolved
PROVIDE CORRECTED CERTIFICATE OF DOCUMENTATION REFLECTING CORRECT TONNAGE. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATER THAN 30JUL 94.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Construction/Loadline
Issued 30 June 1994
Resolved
PROVIDE VENTILATION FOR ALL COMPARTMENTS. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATER THAN 30 JUL 94.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Deck/Cargo
Issued 30 June 1994
Resolved
PROVIDE 65 POUND ANCHOR OR EQUIVALENT. TO BE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATET THAN 30 JUL 94.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994