Records from 1993 to 2025. Most recent: inspection, 15 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 58
15 October 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8252041
12 November 2024
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8033977
24 October 2024
Deficiency Check · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8023893
17 November 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7826163
25 October 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7814536
22 February 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7640378
11 October 2022
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7574773
2 September 2022
Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 7550258
18 January 2022
Appeal · Special Consideration
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7436156
3 November 2021
DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7346663
12 October 2021
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7330584
13 October 2020
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7074784
18 September 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6815909
10 December 2018
Construction Oversight · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6595431
8 November 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577040
11 October 2018
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6560182
4 October 2018
Drydock Exam · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6555886
23 November 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6311805
29 September 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6278208
26 October 2016
Hull Examination · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6030380
25 November 2015
Annual Inspection · Hull Examination · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5788223
13 August 2015
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5214959
16 October 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5006353
31 July 2011
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4102322
15 November 2010
Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3891725
27 October 2008
DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3352400
7 February 2008
Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 3147853
7 November 2007
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3095033
12 December 2005
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2563717
2 November 2005
Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2527044
4 May 2004
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2060261
12 December 2003
Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1963387
8 April 2003
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1770509
13 February 2003
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1744467
23 December 2002
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1722353
10 December 2002
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1717718
13 December 2001
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1473942
18 May 2001
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1063995
18 January 2001
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1056833
2 March 2000
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 817442
15 December 1999
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812402
2 December 1999
Hull Examination · COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1399257
17 December 1998
Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364993
7 January 1998
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1108108
1 December 1997
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1378225
15 January 1997
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1443792
4 December 1996
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1452234
7 November 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 208378
7 November 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 208379
7 November 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 754616
7 November 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 758059
7 March 1996
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1459215
7 February 1996
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363491
11 January 1996
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 884286
30 November 1994
Hull Examination · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355040
28 February 1994
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387475
5 January 1994
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1429849
10 December 1993
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination · Plan Review "T" Boat
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1362889
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 November 2023
Resolved
Each vessel that operates on the high seas must have a FCC Type Accepted Category 1, 406 MHz EPIRB. The EPIRB on the vessel is not for the correct vessel. Place an appropriate EPIRB registered to the vessel on board to the satisfaction of the attending Marine Inspector. 46 CFR 180.64
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2023
Resolution: EPIRB and registration provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2023
Resolved
Each floating waterlight on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip to allow the waterlight to be quickly disconnected from the ring life buoy. The lanyard clip was seized and installed backwards. Install working clip in a manner to allow quick disconnection to the satisfaction of the attending marine inspector. 46 CFR 180.70(d)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 December 2023
Resolution: New clip provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 6 December 2023
Resolution: AED pads provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2023
Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station. Procedures for vapor detection system operation were not posted. Post appropriate procedures for checking the proper operation of a flammable vapor detection system at the operating stations to the satisfaction of the attending Marine Inspector. 46 CFR 182.480(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2023
Resolved 6 December 2023
Resolution: Flammable vapor detection procedures provided.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 17 November 2023
Resolved
The master and crew of a vessel will have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Instructions are not posted. Post emergency instructions to the satisfaction of the attending Marine Inspector. 46 CFR 185.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2023
Resolved 6 December 2023
Resolution: Emergency instructions provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 November 2023
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The FCC Safety Radio Certificate is expired. Obtain a valid FCC Safety Radio Certificate for the vessel to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2023
Resolved 6 December 2023
Resolution: FCC Safety Radio Cert provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Four of the five air chambers in the hull failed the Rigid Hull Inflatable test.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2022
Resolved 12 October 2022
Resolution: The four deficient air chambers in the hull passed the follow-on rigid hull inflatable test after satisfactory repair was completed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 October 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel did not have current charts onboard vessel.
46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2022
Resolved 24 October 2022
Resolution: Charts provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 October 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for necessary facilities for passengers and crew. A crack was observed on the port side/forward portion of the bimini near the helm.
46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2022
Resolved 14 November 2022
Resolution: Repaired crack in bimini.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021
Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT agency drug testing regulations. Marine Inspector identified insufficient Company Drug & Alcohol Policy. Update Company Drug & Alcohol Policy to reflect sample provided in Marine Employer's Drug Testing Guide. Identify SAP and provide contact information to all employees.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Develop a plan for after hours collection for Post-Accident DOT chemical tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021
Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Provide proof of pre-employment tests or acceptable alternative as required by this cite for individuals in a safety sensitive position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 October 2021
Resolved
Vessel required to have interlock for blower switch. Vessel exhaust blower interlock not operational on vessel that has fuel tanks for gasoline. Blower switch must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Provide operational interlock.
46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 30 May 2022
Resolution: Vessel installed blower to ignition.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 October 2021
Resolved
A vessel must carry adequate and up to date charts, US Coast Pilot, Light list, tide tables, current tables. Vessel missing latest versions of Nav Pubs. Provide updated versions of Nav Pubs.
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 8 November 2021
Resolution: Nav pubs provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 October 2021
Resolved
Each watertight bulkhead must be capable of remaining watertight. Unused fuel fill creates hole in bulkhead. Cap unused fuel fill and remove associated hose.
46 CFR 179.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 8 November 2021
Resolution: Bulkhead capped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2021
Resolved
The number and identification of the lifejackets stowed inside container must be marked in clearly legible 2 inch letters. Adult lifejacket signage missing. Provide signage.
46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 8 November 2021
Resolution: Lifejacket sign provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 October 2021
Resolved
Portable fire extinguisher showing corrosion. Replace portable fire extinguisher.
46 CFR 181.500
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 November 2021
Resolved 8 November 2021
Resolution: New extinguisher provided.
Lifesaving › Lifefloat › Serviceable
Issued 29 September 2017
Resolved
Lifefloat in need of renewal.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2017
Resolution: Lifefloat provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 October 2014
Resolved
Replace 2 substandard adult lifejackets.
Due 16 October 2014
Resolved 16 October 2014
Resolution: Vessel replaced lifejackets.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 November 2007
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2007
Resolved 9 November 2007
Documentation › Logs/Records › Logbook (official)
Issued 2 November 2005
Resolved
Provide lifesaving equipment maintenance records.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 15 December 2005
Communications › Radio Communications › EPIRB
Issued 2 November 2005
Resolved
renew EPIRB antenna and update NOAA registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 1 December 2005
Engineering › Fuel Oil Service System › Tank
Issued 2 November 2005
Resolved
Provide grounding for fuel fill fitting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 2 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 2 November 2005
Resolved
Crop and renew pitted hull plating 6' forward of transome and 2' up on both sides of CVK.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 12 December 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 November 2005
Resolved
Prove running lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 2 November 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 2 November 2005
Resolved
Provide two portable lights.
Due 2 December 2005
Resolved 12 December 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 2 November 2005
Resolved
Renew fixed fire fighting slystem storage bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 12 December 2005
Lifesaving › Lifefloat › Paddle
Issued 2 November 2005
Resolved
Secure paddles in lifefloat and mark with vessels name.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 1 January 2006
Documentation › Markings/Placards › Certificate of Number (state)
Issued 2 November 2005
Resolved
Affix HA registration decals to vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 November 2005
Resolved 1 January 2006
Construction/Loadline › Hull › Hull Plating
Issued 2 November 2005
Resolved
Prove stbd side sponson baffel.
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 21 November 2006
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 4 May 2004
Resolved
Install switch for exhaust blower that is interlocked with ignition.
Condition: Placed in Improper Service
Due 18 May 2004
Resolved 2 November 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2003
Resolved
Repair or remove dead end wires at operation station, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 12 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 12 December 2003
Resolved
Provide hiking straps. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 2 January 2004
Resolved 4 May 2004
Navigation › Piloting/Steering
Issued 12 December 2003
Resolved
Provide compass. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Due 20 December 2003
Resolved 4 May 2004
Lifesaving › Buoyant Apparatus
Issued 12 December 2003
Resolved
Provide water light. LEGACY COMPONENT DESC: water light
Condition: Placed in Improper Service
Due 13 December 2003
Resolved 4 May 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 12 December 2003
Resolved
Provide serviced (1) B-II fire extinguisher prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 12 December 2003
Engineering › Bilge Water Management System
Issued 12 December 2003
Resolved
Provide visual indicator for auto bilge pump at operating station. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Due 12 January 2004
Resolved 4 May 2004
Engineering › Fuel Oil Service System
Issued 12 December 2003
Resolved
Provide J-1942 fuel hoses IAW 46CFR182.720(e)(1). LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 12 January 2004
Resolved 4 May 2004
Fire Fighting › Ventilation Systems › Fans
Issued 12 December 2003
Resolved
Prove proper operation of exhaust blower prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 12 December 2003
Fire Fighting › Remote Fuel Shutoff
Issued 12 December 2003
Resolved
Prove proper operation of fuel shutoffs.
Condition: Improper/Lack of Maintenance
Due 12 January 2004
Resolved 4 May 2004
Fire Fighting › Ventilation Systems
Issued 12 December 2003
Resolved
Prove proper operation of blower interlock system and install warning sign. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 12 December 2003
Construction/Loadline › Hull
Issued 12 December 2003
Resolved
Make proper repairs to seam between #4 and #5 baffle. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 12 January 2004
Resolved 4 May 2004
Fire Fighting › Ventilation Systems › Operating Controls
Issued 12 December 2003
Resolved
Prove proper operation of vapor detector. No passengers ops until SAT operation.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 12 December 2003
Construction/Loadline › Hull
Issued 12 December 2003
Resolved
Provide patch kit. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 12 January 2004
Resolved 4 May 2004
Electrical › Electrical Distribution System (service)
Issued 10 December 2002
Resolved
Remove dead end wires located at operating station. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 16 December 2002
Resolved 20 December 2002
Electrical › Electrical Distribution System (service)
Issued 10 December 2002
Resolved
Remove dead end wires located in fuel tank compartment. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Due 16 December 2002
Resolved 20 December 2002
Construction/Loadline › Structures
Issued 10 December 2002
Resolved
Repair fractures (2) in deck plate located near operating station. LEGACY COMPONENT DESC: Deck Plating
Condition: Unknown
Due 16 December 2002
Resolved 8 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 December 2002
Resolved
Provide eye wash and traingular bandage for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 16 December 2002
Resolved 20 December 2002
Communications › Radio Communications
Issued 10 December 2002
Resolved
Prove proper operation of EPIRB. Vessel restricted from carrying passengers. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 10 December 2002
Resolved 20 December 2002
Documentation › Logs/Records
Issued 10 December 2002
Resolved
Provide drug audit material for CG inspection. LEGACY COMPONENT DESC: Drug Test Records
Condition: Unknown
Due 16 December 2002
Resolved 20 December 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 10 December 2002
Resolved
Prove proper operation of fuel shutoff valves. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 23 December 2002
Resolved 20 December 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 10 December 2002
Resolved
Provide vapor detector system IAW 46CFR182.480 prior to carrying passengers. LEGACY COMPONENT DESC: Ventilation
Condition: Placed in Improper Service
Due 10 December 2002
Resolved 20 December 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 10 December 2002
Resolved
Provide servicing report for fixed fire system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 20 December 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 December 2002
Resolved
Provide B-II portable fire extinguisher IAW COI prior to carrying passengers. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 10 December 2002
Resolved 20 December 2002
Lifesaving › Hand Flares
Issued 10 December 2002
Resolved
Provide signaling devices; 6 red hand flare and 6 orange day smoke. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 10 December 2002
Resolved 20 December 2002
Navigation › Piloting/Steering
Issued 10 December 2002
Resolved
Provide US Coast Pilot and rules to the road. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 16 December 2002
Resolved 20 December 2002
Engineering › Bilge Water Management System › Pump
Issued 13 December 2001
Resolved
Portable hand bilge pump would not operate.
Condition: Unknown
Due 13 December 2001
Resolved 13 December 2001
Resolution: The portable hand bilge pump was replaced and tested SAT.
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 December 2001
Resolved
Rejected three adult life jackets. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 13 December 2001
Resolved 13 December 2001
Resolution: Three CG approved lifejackets were provided.
Navigation › Piloting/Steering
Issued 13 December 2001
Resolved
Missing CG light list and tide tables. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 13 December 2001
Resolved 13 December 2001
Resolution: Vessel provided CG light list and tide tables.
Construction/Loadline
Issued 2 December 1999
Resolved
Possible fracture in aluminum deck 12 feet from stem. Remove paint and made ready for closer inspection by USCG Marine Inspector NLT 16DEC99 IAW 46CFR176.610.
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Construction/Loadline
Issued 2 December 1999
Resolved
Conduct an alternate chamber pressure test in the presence of an attending Marine Inspector with a gauge suitable to the Marine Inspector IAW MSO Honolulu Inspection Note #22 NLT 16DEC99.
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Fire Fighting
Issued 2 December 1999
Resolved
Make provision to close all supply and exhaust duct openings to fuel tank space IAW 46CFR182.15-45(h) NLT 2JAN00.
Condition: Unknown
Due 30 December 1999
Resolved 30 December 1999
Fire Fighting
Issued 17 December 1998
Resolved
Found no documentation of annual NFPA 10 servicing for portable and fixed fire extinguishing equipment present. Fixed bottle recently past the hydro date. Provide documentation of NFPA 10 servicing on portable and fixed firefighting equipment.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Construction/Loadline
Issued 17 December 1998
Resolved
Vessel did not complete a satisfactory alternate chamber pressure test. Conduct a satisfactory alternate chamber test in presence of a USCG marine inspector.
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Engineering
Issued 1 December 1997
Resolved
Replace vinyl vent material with rigid fire resistant material as per 46 CFR 182.460(h).
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 4 December 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Construction/Loadline
Issued 4 December 1996
Resolved
REPAIR AS PER ORIGINAL CRACK IN PORT ENGINE MOUNT IN VICINITY OF UPPER BOLT, OUTBOARD SIDE, TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Documentation
Issued 7 February 1996
Resolved
Provide FCC operators license for Terence Mangold.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Engineering
Issued 7 February 1996
Resolved
Prior to 14 Feb 96, make repairs to the engine mounting brackets where fractured.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Lifesaving
Issued 7 February 1996
Resolved
Provide one additional smoke flare.
Condition: Unknown
Due 9 February 1996
Resolved 16 February 1996
Fire Fighting
Issued 7 February 1996
Resolved
Provide evidence of annual service of fixed fire fighting equipment.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Construction/Loadline
Issued 7 February 1996
Resolved
Provide hand bilge/fire 5 GPM pump.
Condition: Unknown
Due 9 February 1996
Resolved 16 February 1996
Documentation
Issued 7 February 1996
Resolved
Prior to carrying passengers for hire provide evidence of compliance with chemical testing regulations.
Condition: Unknown
Due 7 February 1996
Resolved 7 February 1996
Documentation
Issued 7 February 1996
Resolved
Provide emergency check off list.
Condition: Unknown
Due 9 February 1996
Resolved 16 February 1996
Documentation
Issued 30 November 1994
Resolved
PROVIDE PROPER DOCUMENTATION OF A VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Engineering
Issued 5 January 1994
Resolved
PERMANENTLY MOUNT RED WARNING SIGN AT BLOWER SWITCH THAT STATES "PRIOR TO ENGINE STARTING, BLOWER SHALL BE OPERATED TO ALLOW FOR AT LEAST ONE COMPLETE AIR CHANGE IN FUEL TANK COMPARTMENTS." 46CFR182.15-45(d)_x001C_ _x001C_
Condition: Unknown
Due 5 January 1994
Resolved 5 January 1994
Fire Fighting
Issued 5 January 1994
Resolved
INSTALL MECHANICALLY OPERATED VENTILATION CLOSURES TO FUEL TANK SPACE. 46CFR182.15-45(h)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1994
Resolved 5 January 1994
Documentation
Issued 10 December 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993