COQUI II

COQUI II is a 1994 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1994, most recently in April 2026, along with 145 deficiencies and 3 operational controls.

Records from 1994 to 2026. Most recent: inspection, 7 April 2026.

Built
1994
Last inspected
7 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7132
398541
Flag
UNITED STATES
367066670, 368369370
Maury page id
psix-398541

Inspections, by type

…with no type recorded5
Years with a record 25 calendar years (1994–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.3 ft × 12.5 ft × 6.7 ft
Registered tonnagegross 23 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderREX-MEYER YACHTS INC · SANFORD, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portST THOMAS, VI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7132MMSI 367066670 · active · compulsorily equipped · granted 26 June 2025, expires 13 September 2035
WDP6091MMSI 368369370 · active · voluntarily equipped · granted 23 May 2024, expires 23 May 2034
WDA5461MMSI 366820350 · expired · voluntarily equipped · granted 24 July 2001, cancelled 24 September 2011
WCW9178MMSI not assigned · expired · compulsorily equipped · granted 25 October 1996, cancelled 30 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

7 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8346843
21 April 2025 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8116346
25 November 2024 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8047213
16 January 2024 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7863445
12 January 2023 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7604781
28 November 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7604180
5 November 2021 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7344463
11 January 2021 Administrative Inspection · Annual Inspection · Drydock Exam · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7132106
20 December 2019 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6880449
31 January 2019 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6616803
4 December 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6592023
13 November 2018 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6579366
14 November 2017 In-Service Inspection · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6306935
16 October 2017 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288687
27 March 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6112380
10 March 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6102523
7 February 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6084036
23 November 2016 Deficiency Check · Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6046468
22 January 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5801872
14 July 2009 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3534018
14 July 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3536127
29 September 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3330795
30 June 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3253509
5 July 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2703444
18 January 2006 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2569216
21 November 2005 Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2538611
7 October 2005 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2512107
7 September 2005 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2486406
28 September 2004 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2206951
23 June 2004 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2108917
16 July 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1860626
29 October 2002 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1702259
12 December 2001 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1481375
7 September 2001 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1073470
23 July 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1406988
14 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397666
14 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1399688
12 October 2000 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466174
27 October 1999 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1463519
29 September 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 794484
20 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 731988
12 August 1999 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1442882
2 May 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 97026
1 April 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1120016
17 November 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 806840
27 May 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 792058
20 April 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 802899
13 November 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 782824
6 May 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098866
22 April 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099047
13 December 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091779
10 October 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1151476
22 August 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1087398
15 May 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082997
8 May 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1083764
13 October 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 876737
22 August 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877556
5 June 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874969
18 May 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1238975
22 April 1994 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 857008
9 February 1994 Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 849359

Deficiency record · 145

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 December 2018 Resolved
A vessel must carry one floating waterlight. Vessel's waterlight is non-operational. Vessel is restricted to daylight operations until proper operation of the waterlight can be demonstrated.
Action required: 705 - Other - as specified
Resolved 6 December 2018
Resolution: Received video from operator of working waterlight.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 December 2018 Resolved
Provisions must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The port side ventilation in the engine space does not properly close due to wires and packing foam blocking the closure.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 December 2018
Resolution: Received video from operator demonstrating proper closing of the ventilation for the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 December 2018 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The shaft in the steering compartment does not have a guard or cover and poses a hazardous condition in the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 December 2018
Resolution: Received picture from operator of machinery guard in place.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 December 2018 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel is missing the required ammonia inhalants.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2018
Resolution: Received invoice and picture of ammonia inhalants.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 December 2018 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. The vessel did not have any life jacket placards posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 December 2018
Resolution: Received photo of lifejacket donning placard displayed on the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2018 Resolved
A vessel of at least 26 feet in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. One of the vessel's manual bilge line is disconnected from itself. Properly secure line or remove system from on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 December 2018
Resolution: Received photo of bilge system properly in place.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 December 2018 Resolved
A vessel on a limited coastwise route must carry six hand orange smoke distress signals. Vessel has four distress signals expiring at the end of the month.
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 4 December 2018
Resolution: Operator brought new flares on board before departing the vessel.
Engineering › Feedwater/Condensate Water System › Gauge
Issued 27 March 2017 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vesselAlso noted high water cooling temperature displayed on cooling water temperature gauge, also at steering console. After Master diagnosed, faluty gauge was found to be the source of the high temperature reading.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 3 April 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 March 2017 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(1) Be buoyant;Vessel did not have 60ft of bouyant lifeline on board for lifebouy. Line that was attached to life bouy did not float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 3 April 2017
Resolution: Verified vessel had approved life line for the life ring. Cleared deficiency.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 March 2017 Resolved
High bilge alarm visual not working
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 3 April 2017
Engineering › Fuel Oil Service System › Hose
Issued 23 November 2016 Resolved
The flexible fuel hose from the service tank to the fuel filter passes unprotected through the bulkhead. Correct flexible fuel hose penetrating forward engine room bulkhead.
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: Protection was provided for the fuel hose.
Engineering › Fuel Oil Service System › Gauge
Issued 23 November 2016 Resolved
The installed marine type fuel gauge had been removed and the vessel operator was using a wooden dowel with markings to get sounding through the top of the fuel tank. Provide adequate means to measure fuel level.
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: A gauge was installed on the fuel tank.
Engineering › Bilge Water Management System › Valve
Issued 23 November 2016 Resolved
A plastic through-hull fitting was discovered on the bilge discharge piping in the fuel compartment. Replace plastic through-hull fittings with metallic fittings.
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: Valve was replaced with a metallic alternative.
Engineering › Bilge Water Management System › Valve
Issued 23 November 2016 Resolved
There is a ball valve used as the isolation valve installed on the bilge line outside the collision bulkhead. Replace valve on forward collision bulkhead bilge piping with gate valve (screw down valve).
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: A gate valve was installed.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 23 November 2016 Resolved
Multiple cracks were noted on the swim deck ladder and on the underside of the support stanchions. Repair cracked welds on swim deck ladder and on underside of swim deck for welds on stanchion supports.
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: Compromised welds were ground down and re-welded.
Stability › Watertight Integrity › General
Issued 23 November 2016 Resolved
The fiberglass deck had multiple cracks next to the engine room cover. Repair / dewater cracks on deck next to engine room cover.
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: The deck cracks were ground down and repaired with FRP.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 November 2016 Resolved
There is an exposed belt on the engine with no machinery guard in place. Provide machinery guard.
Action required: 705 - Other - as specified
Resolved 22 December 2016
Resolution: A machinery guard was provided for the exposed belt.
Documentation › Certificates/Documents › FCC SSL
Issued 26 January 2016 Resolved
PROVIDE CURRENT FCC STATION LICENSE, RESTRUCTED TO 1,000 FT. FROM SHORE.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 March 2016
Resolution: Rceived copy of new FCC station license.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 January 2016 Resolved
PROPERLY SECURE AFT COMPARTMENT THROUGH-HULL PENETRATION. THERE IS A FITTING CONNECTED WITH A LOOSE HOSE AND PVC VALVE.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 16 February 2016
Resolution: Vessel operator replaced PVC through hull fitting with bronze fitting and cap to secure.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 26 January 2016 Resolved
PROVIDE PROPER OPERATION OF FIXED PRE-ENGINEERED FIRE FIGHTING SYSTEM.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2016
Resolution: Properly tested pre-engineered FF system. All satisfactory.
Engineering › Steering Gear System › Linkage
Issued 26 January 2016 Resolved
PROPERLY REPAIR EMERGENCY STEERING TILLER LINKAGE.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2016
Resolution: Vessel operator properly repaired secondary means of steering.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 January 2016 Resolved
SECURE ALL LOOSE/HANGING WIRES ON FUEL-TANK COMPARTMENT.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 16 February 2016
Resolution: Vessel operator secured all loose and hanging wires.
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 January 2016 Resolved
CONDUCT SATISFACTORY DRILLS AND SEA-TRIALS IN THE PRESENCE OF CG MARINE INSPECTOR.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 29 March 2016
Resolution: Conducted sea trials on board vessel and witnessed satisfactory fire and man overboard drills.
Construction/Loadline › Hull › Collision Chock
Issued 26 January 2016 Resolved
PROPERLY SECURE/REPAIR ACCESS IN COLLISION BULKHEAD/FWD COMPARTMENT WHERE THERE IS WATER INGRESS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 16 February 2016
Resolution: Vessel operator secured areas where water was entering space.
Engineering › Fuel Oil Service System › Hose
Issued 26 January 2016 Resolved
PROVE FLEXIBLE FUEL HOSE AND ENGINE COMPARTMENT AND FUEL TANK MEETS ASTM D1692 OR REPLACE FELXIBLE FUEL HOSE WITH APPROVED TYPE.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 February 2016
Resolved 16 February 2016
Resolution: Non-approved hoses where repalced with approved type fuel hoses.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 July 2009 Resolved
Provide technician's report for properly installed and functioning fireboy system in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 August 2009
Resolution: Tested fireboy system on 04Aug09. System is working properly. all sat.
Construction/Loadline › Structures › Deck Plating
Issued 14 July 2009 Resolved
Submit repair proposal for cracked deck between engine compartment and fwd compartment.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Repair completed for cracked deck between engine compartment and fwd compartment. all sat.
Construction/Loadline › Structures › Deck Plating
Issued 14 July 2009 Resolved
Submit repair proposal for cracked deck stbd aft corner.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Cracked deck stbd aft corner is repaired. all sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 July 2009 Resolved
Submit repair proposal for ensuring a watertight bulkhead between the engine compartment and the fwd compartment.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 July 2009 Resolved
Provide top covers for the two battery boxes in the engine compartment.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Top covers were provided for the two battery boxes in the engine compartment. all sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 July 2009 Resolved
Provide covering for electric panel in engine compartment to ensure panel does not get splashed with water.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Construction/Loadline › Structures › End Bulkhead
Issued 14 July 2009 Resolved
Make transom watertight.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Transom is now watertight. all sat.
Stability › Watertight Integrity › General
Issued 14 July 2009 Resolved
Install check valves for all thru hull fittings.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 July 2009 Resolved
Replace (15) fifteen adult lifejackets.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 July 2009 Resolved
Replace retro-reflective tape on (04) four child-size lifejackets.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 July 2009 Resolved
Provide adequate retro-reflective tape on all remaining adult lifejackets (07) seven total.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 July 2009 Resolved
Provide properly working and approved self-igniting light for life buoy.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Self-igniting light for life ring buoy is all sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 July 2009 Resolved
Repair mounting for water tank in fwd compartment.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Mounting is repaired for water tank in fwd compartment.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 July 2009 Resolved
Provide proper latch on stbd side engine room cover.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Latch on stbd side engine room cover is all sat.
Engineering › Freshwater System (jacketwater cooling) › Containment
Issued 14 July 2009 Resolved
Make proposal to re-locate anti-freeze resevoir recovery.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Anti-freeze resevoir recovery system is all sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2009 Resolved
Remove excess studs on overhead deck plates.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: All excess studs on overhead deck plates have been removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2009 Resolved
Remove all exposed excess studs on bracketry.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: All exposed excess studs on bracketry have been removed.
Engineering › Bilge Water Management System › Not Operational
Issued 14 July 2009 Resolved
remove or repaire bilge alarm system in fwd compartment by fuel tank.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: System was removed in fwd comaprtment by fuel tank.
Engineering › Steering Gear System › Ram
Issued 14 July 2009 Resolved
Repair hydraulic ram leak in aft compartment.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Hydraulic ram leak in aft compartment has been repaired. all sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 14 July 2009 Resolved
Repair cracked swim ladder at hinge plate.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Hinge plate for swim ladder has been replaced. all sat.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 July 2009 Resolved
Ensure compliance with ability to conduct alcohol testing within two hours, an additional DOT approved sampling kit is required on board.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 14 July 2009 Resolved
Repair hanging and ripped insulation inside engine room cover.
Action required: 705 - Other - as specified
Resolved 4 August 2009
Resolution: Insulation inside engine room cover has been repaired and is no longer hanging. all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2009 Resolved
Provide metal brackets for hanging wiring in fwd compartment.
Action required: 705 - Other - as specified
Resolved 12 August 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 July 2009 Resolved
Vessel must conduct MOB drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2009
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 October 2008 Resolved
Repair fixed fire fighting system indicator and main engine reset device at the pilot station. At time of this def check, it was determined that the incorrect indicator was installled. At time of inspection, the visual indicator worked, but the audible was still patched to the engine room bilge pump alarm buzzer. The reset work one time, then failed the second time.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2008
Resolved 10 November 2008
Resolution: Observed proper operation of new indicator. All Sat. JAR
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 29 September 2008 Resolved
Provide a B-II portable fire extinguisher. At time of inspection, a B-I was in place of the required B-II. The B-I needed to be serviced due to frozen discharge handle.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2008
Resolved 3 October 2008
Resolution: A new B-II portable provide and installed in forward cabin.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 September 2008 Resolved
Repair electric wire that connects to the fixed fire fighting system cylinder head in engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2008
Resolved 3 October 2008
Resolution: New fitting provided.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 September 2008 Resolved
Repair the fixed fire fighting system indicator at the pilot station. The green light at the indicator was not working at time of the inspection indicating that the system is operational.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 September 2008
Resolved 3 October 2008
Resolution: Requirement re-issued to reflect additional details that need to be addressed. See narrative.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 2008 Resolved
Repair navigation lights. At time of inspection, the stern white light worked, but the port and starboard lights did not work. Vessel restricted to daytime ops only and not during restricted visibility.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 3 October 2008
Resolution: New lights installed and tested sat.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 29 September 2008 Resolved
Repair or replace waterlight to ringbuoy. At time of inspection, the waterlight was working intermitently. Vessel restricted to daytime ops only and not during restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2008
Resolved 3 October 2008
Resolution: A new waterlight provided and tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 September 2008 Resolved
Provide lifejacket donning placard.
Condition: Improper Installation
Due 3 October 2008
Resolved 3 October 2008
Resolution: Provided and installed.
Engineering › Lubricating Oil Service System › Gauge
Issued 29 September 2008 Resolved
Repair oil pressure gauge at the pilot station. At time of inspection, gauge was showing incorrect reading. As soon the power was energized to MDE, the gauge needle jumped all the way to max reading.
Condition: Improper Installation
Due 3 October 2008
Resolved 24 November 2008
Resolution: New guage installed and tested sat.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 29 September 2008 Resolved
Repair MDE rpm gauge at the pilot station. Ensure gauge is permanent installed at the console. At time of inspection, the gauge was reading 000 with MDE operating and not fixed to console.
Condition: Design Flaw
Due 3 October 2008
Resolved 24 October 2008
Resolution: New guage installed and tested sat.//JAR
Communications › Radio Communications › VHF Radiotelephone
Issued 29 September 2008 Resolved
Provide FCC marine Radio Operator permit for master.
Due 3 October 2008
Resolved 24 October 2008
Resolution: Copy of certificate provided.//JAR
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 September 2008 Resolved
Make repairs to fly bridge deck. Deck plates are loose presenting a falling hazard to crew members.
Condition: Improper Installation
Due 30 November 2008
Resolved 12 August 2009
Operations/Management › Passenger Operations › Safety Orientation
Issued 5 July 2006 Resolved
Post Emergency Instructions.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Provide master with instructions and master posted them at the passenger deck forward.
Documentation › Logs/Records › Logbook (official)
Issued 5 July 2006 Resolved
Provide a log for drills and lifesaving equipment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Log book provided.
Fire Fighting › Fire Bucket › Quantity
Issued 5 July 2006 Resolved
Provide 2 stenciled fire buckets with lines attached.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Buckets provided.
Navigation › Piloting/Steering › Marine Charts
Issued 5 July 2006 Resolved
Provide correct chart for Puerto Rico.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: New chart provided.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 5 July 2006 Resolved
Provide operational horn.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Provided and tested.
Lifesaving › Hand Flares › Quantity
Issued 5 July 2006 Resolved
Provide three (3) missing orange smokes.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Provided to expire on 08.
Communications › Radio Communications › EPIRB
Issued 5 July 2006 Resolved
Provide EPIRB with new antenna.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: New antenna provided.
Engineering › Steering Gear System › Follow-up Assembly
Issued 5 July 2006 Resolved
Provide emergency steering tiller.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Provided and tested.
Engineering › Non-conventional Propulsion/Steering › Impeller Seat Ring (jet)
Issued 5 July 2006 Resolved
Correct aft water leak on jet drive in steering room// 06Jul06- System tested underway. Noted leak only when going in reverse and in neutral, but not going forward. No leak noted with vsl moored and system off. Master instructed to monitor space and to test high level alarm and bilge pump prior to carry passengers. New bushing already ordered by owner.
Condition: Design Flaw
Due 27 July 2006
Resolved 21 August 2006
Resolution: Received photos ans statement of bushing replacement from owner.
Operations/Management › Drills/Instruction › Fire
Issued 5 July 2006 Resolved
Conduct fire and man overboard drills with CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Resolution: Conducted fire and man overboard drills while underway.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 5 July 2006 Resolved
Provide 2 emergency portable lights.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 September 2005 Resolved
Service portable fire extinguisher located at the pilot station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2005
Resolution: Received via fax invoice for a new portable fire extinguisher.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 September 2005 Resolved
Repair the starboard side top safety rail.
Condition: Improper/Lack of Maintenance
Due 7 October 2005
Resolved 7 October 2005
Documentation › Certificates/Documents › FCC SSL
Issued 7 September 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 7 October 2005
Resolved 13 September 2005
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 8 July 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 July 2004
Resolved 12 July 2004
Resolution: Evidence provided.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 8 July 2004 Resolved
Provide 3rd party report for annual servicing of the fixed fire fighting system. Both bottles have proper servicing tags.
Condition: Improper/Lack of Maintenance
Due 8 August 2004
Resolved 21 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 July 2004 Resolved
Provide a Cost Guard or equivalent first aid kit.
Condition: Improper/Lack of Maintenance
Due 8 August 2004
Resolved 8 August 2004
Resolution: Recd statement of corretion from operator [name withheld]
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 July 2004 Resolved
Provide additional safety chains so that no more than 12 inches exist from the main deck to the top rail, aft by dive platform. Rail courses not to exceed 12 inches apart.
Condition: Improper Installation
Due 8 August 2004
Resolved 12 July 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 July 2004 Resolved
Provide a 3-foot lanyard with a corrosion resistant clip to water light for the lifebuoy.
Condition: Improper Installation
Due 8 August 2004
Resolved 21 July 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 July 2004 Resolved
Mark lifebuoy with vessel name.
Condition: Improper/Lack of Maintenance
Due 8 August 2004
Resolved 21 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 8 July 2004 Resolved
Separate adult from child lifejackets.
Condition: Improper Installation
Due 8 August 2004
Resolved 8 August 2004
Resolution: Done.
Engineering › Steering Gear System › Valve, Control
Issued 8 July 2004 Resolved
Replace the current "leverage pipe" with a smaller diameter pipe for the emergency steering system handle.
Condition: Improper Installation
Due 8 August 2004
Resolved 21 July 2004
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 July 2004 Resolved
Label the remote fuel shut-off valve with direction of operation.
Condition: Improper/Lack of Maintenance
Due 8 August 2004
Resolved 21 July 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 8 July 2004 Resolved
Permanently install the portable fire extinguishers.
Condition: Improper Installation
Due 8 August 2004
Resolved 21 July 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 June 2004 Resolved
Storage bags for the adult PFDs are too tight for PFD storage, which makes it very difficult to extract the PFDs. Provide storage bags that allow suitable/quicker extraction, or provide an alternative PFD stowage arrangement as per 46 CFR 180.78.
Due 3 September 2004
Resolved 27 September 2004
Resolution: Operator stated that lifejackets are stored outside the bags since they were unabled to obtain larger bags.
Construction/Loadline › Hull › Bottom Plating
Issued 16 July 2003 Resolved
Prior to carrying passengers, renew as original the aluminum bottom plate for the jet drive intake foundation. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Plate replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 16 July 2003 Resolved
Prior to carrying passengers, renew as original the aluminum jet drive mount to the stern. LEGACY COMPONENT DESC: Bracket
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Jet replaced.
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Prior to carrying passengers, renew as original all missing and pitted directional / stabilizer fins and properly reseal to hull.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2003
Resolved 23 June 2004
Resolution: Fins replaced.
Engineering › Steering Gear System › Fastener
Issued 16 July 2003 Resolved
Prior to carrying passengers, install adequate washer or device for the new steering cable terminus. LEGACY COMPONENT DESC: Linkage
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Replaced.
Construction/Loadline › Structures › Deck Plating
Issued 16 July 2003 Resolved
Prior to carrying passengers, reweld all fractures to dive platform base and the dive ladder.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 8 July 2004
Resolution: Items rewelded.
Construction/Loadline › Structures › Superstructure
Issued 16 July 2003 Resolved
Install missing securing bolts to flying bridge supports (six total).
Condition: Improper Installation
Due 30 June 2004
Resolved 8 July 2004
Resolution: Replaced.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 16 July 2003 Resolved
Prior to carrying passengers, install missing vertical rail to bow sprit. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 8 July 2004
Resolution: Railing repaired.
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2003 Resolved
Make port and starboard side elecrical cable runs weather tight where wires are currently exposed at flying bridge.
Condition: Improper Installation
Due 28 August 2003
Resolved 23 June 2004
Resolution: Repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2003 Resolved
Drain water in aft deck light fixture and reseal.
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 23 June 2004
Resolution: Replaced.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 16 July 2003 Resolved
Install adequate fuel filter and gauge. Provide a steel strainer bowl for fuel filter.
Condition: Improper/Lack of Maintenance
Due 28 August 2003
Resolved 23 June 2004
Resolution: New filter system installed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Control Valve
Issued 16 July 2003 Resolved
Prior to carrying passengers, properly secure the fixed fire fighting pull cable where cable ends at the cylinder's nozzle. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: System installed as design.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Silencer (exhaust)
Issued 16 July 2003 Resolved
Renew the exhaust seal where water leaks are present.
Condition: Design Flaw
Due 28 August 2003
Resolved 23 June 2004
Resolution: Renewed.
Electrical › Electrical Distribution System (service) › Conductor
Issued 16 July 2003 Resolved
Remove all dead end wires in engine and forward compartments.
Condition: Improper Installation
Due 28 August 2003
Resolved 23 June 2004
Resolution: Wiring replaced.
Construction/Loadline › Penetrations › Pipe Flange
Issued 16 July 2003 Resolved
Prior to carrying passengers, properly plug unused through-hull fiting for the obsolete sewage line.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Pipe removed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 16 July 2003 Resolved
Prior to carrying passengers, renew throttle linkage terminus with a metal fiting or clip to replace current plastic tie. LEGACY COMPONENT DESC: Governor
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 8 July 2004
Resolution: Repaired.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 16 July 2003 Resolved
Prior to carrying passengers, free and clean intake valve for the engine cooling water. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Repaired.
Construction/Loadline › Hull › Hull Plating
Issued 16 July 2003 Resolved
Renew extensive cracks in fiber glass knife edges to the engine compartment hatch.
Condition: Damaged By Earlier Event
Due 28 August 2003
Resolved 23 June 2004
Resolution: Renewed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 29 October 2002 Resolved
Provide proper fire extinguisher cylinder for fixed fire extinguishing system. replace cylinder from 9.5lbs to a 16lbs as per COI.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2002
Resolution: Cylinder replaced.
Documentation › Certificates/Documents
Issued 29 October 2002 Resolved
Provide evidence that new crew member is enrolled in a drug testing consortium.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2002
Resolution: Evidence provided.
Engineering › Steering Gear System › Rudder
Issued 29 October 2002 Resolved
Repair Auxiliary steering system (tiller) and prove proper operation to a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 30 June 2004
Resolved 8 July 2004
Resolution: Syestem replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 29 October 2002 Resolved
Provide service report for fixed fire extinguisher and portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2002
Resolution: Service report provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 December 2001 Resolved
Install & provide missing and required portable fire extinguisher ( type B-II).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2002
Resolution: Provided new portable fire extinguisher (type B-II)..
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 December 2001 Resolved
Service all portable fire extinguishers on board. LEGACY COMPONENT DESC: Service
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2002
Resolution: Serviced Portable fire extinguisher.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 12 December 2001 Resolved
Proof proper operation of vessel fixed fire extinguishing syatem onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2002
Resolution: Master and crew member sat demonstrated use of fixed fire fighting system.
Personnel › Certificates/Documents/Licenses
Issued 12 December 2001 Resolved
Vessel to have a Coast Guard licensed Master when carrying seven or more passengers for hire. LEGACY COMPONENT DESC: License, Master
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2002
Resolution: Vessel owner/opertors hired licensed Master.
Documentation › Logs/Records
Issued 12 December 2001 Resolved
Vessel to have a Training Log Book on board to log drills conducted by crew. LEGACY COMPONENT DESC: Logbook (official)
Due 12 January 2002
Resolved 1 February 2002
Resolution: Master provided required training record log book.
Documentation › Certificates/Documents
Issued 12 December 2001 Resolved
Provide Stability Letter for exposed water operation (operations of more than three miles from shore). Vessel has a Limited Coastwise route in its present COI. LEGACY COMPONENT DESC: Stability Letter
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 29 October 2002
Resolution: Owner requested that route be changed to Lakes, Bays and sound. This route is acceptable as per stability letter.
Operations/Management › Drills/Instruction
Issued 12 December 2001 Resolved
Crew to demonstrate man overboard drill. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2002
Resolution: Crewmembers executed sat drills onboard and underway this date.
Construction/Loadline
Issued 23 July 2001 Resolved
Properly cancel existing non-utilized sea valves previously used for MSD unit.
Condition: Unknown
Due 28 July 2001
Resolved 23 July 2001
Engineering
Issued 23 July 2001 Resolved
Install missing bracket (hose clamp), on wet exhaust hose.
Condition: Unknown
Due 28 July 2001
Resolved 31 July 2001
Documentation
Issued 14 June 2001 Resolved
VESSEL TO PROVIDE CURRENT FCC(COMMUNICATION ACT SAFETY RDIO CERTIFICATE).
Condition: Unknown
Due 14 June 2001
Resolved 22 August 2001
Documentation
Issued 14 June 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Navigation
Issued 14 June 2001 Resolved
VESSEL TO REGISTER WITH NOAA, 406 SATELITE EPIRB REGISTRATION
Condition: Unknown
Due 14 June 2001
Resolved 22 August 2001
Documentation
Issued 14 June 2001 Resolved
Vessel to provide current FCC Communication Safety Act Radiotelephony Certificate. Vessel not allowed to carry more than six(6) passengers until requirement is met.
Condition: Unknown
Due 14 July 2001
Resolved 22 August 2001
Lifesaving
Issued 14 June 2001 Resolved
Vessel to register it's required 406 MHZ EPIRB.
Condition: Unknown
Due 14 July 2001
Resolved 22 August 2001
Documentation
Issued 14 June 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 July 2001
Resolved 7 September 2001
Navigation
Issued 12 October 2000 Resolved
Make emergency steering system available for full operation and testing no later than 28 OCT 00.
Condition: Unknown
Due 28 October 2000
Resolved 31 October 2000
Fire Fighting
Issued 22 April 1997 Resolved
Perform annual servicing on fixed halon system and portable extinguishers._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Electrical
Issued 22 April 1997 Resolved
Provide 2 emergency flashlights.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Permanently mount EPIRB to allow float free deployment.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Stencil name of vessel on lifefloat and ringbuoy. Affix retro-reflective tape on lifefloat.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Documentation
Issued 22 April 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Provide one additional adult PFD. Limited to 21 total persons until completed.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Renew retro-reflective tape on 2 adult PFD's.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Documentation
Issued 22 April 1997 Resolved
Renew garbage placard.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Lifesaving
Issued 22 April 1997 Resolved
Permanently mount bracket for waterlight on ringbuoy.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Fire Fighting
Issued 22 April 1997 Resolved
Install lanyards on fire buckets.
Condition: Unknown
Due 29 April 1997
Resolved 7 May 1997
Documentation
Issued 8 May 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Post emergency check-off list.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Stencil lifefloat with vessel's name and capacity.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Restencil ringbuoy with vessel's name.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Provide 2 additional orange flares.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Renew battery in waterlight for ringbuoy.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Provide watertight container for flares.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Engineering
Issued 8 May 1996 Resolved
Repair emer. fuel shutoff and stencil.
Condition: Unknown
Due 15 May 1996
Resolved 16 May 1996
Documentation
Issued 8 May 1996 Resolved
Renew Certificate of Documentation.
Condition: Unknown
Due 31 May 1996
Resolved 27 June 1996
Fire Fighting
Issued 18 May 1995 Resolved
Perform annual servicing on fixed halon system.
Condition: Unknown
Due 18 May 1995
Resolved 18 May 1995
Lifesaving
Issued 18 May 1995 Resolved
Renew battery in waterlight for ringbuoy.
Condition: Unknown
Due 25 May 1995
Resolved 5 June 1995
Lifesaving
Issued 18 May 1995 Resolved
Provide one additional red flare.
Condition: Unknown
Due 25 May 1995
Resolved 5 June 1995
Lifesaving
Issued 18 May 1995 Resolved
Provide approved type waterlight for L/F.
Condition: Unknown
Due 25 May 1995
Resolved 5 June 1995