MAURY USCG vessel records Sign in
← All vessels

SEIN PHOENIX

SEIN PHOENIX is a 1993 freight ship. The Coast Guard has recorded 24 inspections since 1993, most recently in July 2019, along with 8 deficiencies.

Records from 1993 to 2019. Most recent: inspection, 15 July 2019.

Built
1993
Last inspected
15 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9047271 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
398578
Flag
LIBERIA
—
Maury page id
psix-398578

Inspections, by type

…with no type recorded16
Years with a record 15 calendar years (1993–2019)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it8041 - Dead Weight, Ton
12042 - Displacement, Ton
7326 - Convention (Subpart B), Gross Ton
4810 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 24

15 July 2019 Type not recorded
No type recorded · USCG Arctic District (dr) · USCG Arctic District (CGD-A) · Activity 6841331
21 February 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6354314
28 September 2015 COE-Dockside · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5726617
28 September 2015 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5728463
12 May 2012 ISPS I Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4308190
12 May 2012 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4311390
16 October 2007 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3080896
20 September 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3062354
20 September 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3062400
19 September 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3061308
3 April 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2614618
4 January 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1974389
18 February 2003 Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1746076
30 August 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 281509
19 February 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 274804
27 October 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 421713
23 February 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413169
10 January 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 399333
11 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388750
28 October 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 384349
10 January 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 373846
30 December 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 373849
24 May 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 486581
13 December 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 363052

Deficiency record · 8

Fire Fighting › Portable Foam Applicators › General
Issued 21 February 2018 Resolved
0720-Fire fighting equipement-A portable foam applicator unit shall consist of a nozzle, a tank containing 20l of foam and a spare tank. PSCO observed the 1 spare tank of foam was missing. 74 SOLAS (a) 1997 cons. II-2/6.4 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 February 2018
Resolved 23 February 2018
Resolution: Received class report from BV satisfying the requirements.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 21 February 2018 Resolved
1430-auxilary engines-The condition of the ship shall be maintained to conform with the present regulations. PSCO observed tie backs on all 3 generator manual fuel rack activation handles. 74 SOLAS (a) 2014 cons. I/11(a). 40a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2018
Resolved 23 February 2018
Resolution: Received class report from BV satisfying the requirements.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 20 September 2007 Resolved
Vessels echo depth sounder inoperable and is being completely replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 September 2007
Resolved 21 September 2007
Resolution: Received Radio Holland Service Report for new Echo depth sounder installed and operable.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 20 September 2007 Resolved
Non-tank Vessel Response Plan not onboard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 September 2007
Resolved 16 October 2007
Resolution: VRP website shows NTVRP approved for interm ops.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 20 September 2007 Resolved
Explosion Plate on Incinerator Access Door is missing.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 September 2007
Resolved 9 October 2007
Resolution: Received Class report stating incinerator access door explosion plate has been repaired.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 20 September 2007 Resolved
Vessel failed to apply for Letter of Deviation for inoperation navigation equipment (echo sounder) prior to entry into Port of Los Angeles.
Action required: 705 - Other - as specified
Due 20 September 2007
Resolved 20 September 2007
Resolution: Rcvd faxed tech report verifying proper operation of the echo depth sounder.
Lifesaving
Issued 23 February 1998 Resolved
THE VESSELS RELEASING GEAR WAS FROZEN WHEN CREW TRYED TO LAUNCH LIFEBOAT_x001C_ THE VESSEL WAS ISTRUCTED TO PROVIDE CLASS REPORT PRIOR TO THE VESSEL DEPARTING PORT.
Condition: Unknown
Due 25 February 1998
Resolved 25 February 1998
Electrical
Issued 10 January 1997 Resolved
EMERGENCY GENERATOR FAILED TO START.
Condition: Unknown
Due 10 January 1997
Resolved 10 January 1997

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.