PRIDE WISCONSIN is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 41 inspections since 1993, most recently in December 2020, along with 63 deficiencies.

Records from 1993 to 2020. Most recent: inspection, 23 December 2020.

Built
1976
Last inspected
23 December 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8752142 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO4469
398626
Flag
UNITED STATES
—
Maury page id
psix-398626

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (1993–2020)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5955 - Convention (Subpart B), Gross Ton
1786 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 41

23 December 2020 Administrative Inspection · Exemption
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7119448
18 January 2007 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2858082
15 May 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1617033
6 May 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1749464
22 March 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495888
23 February 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1488664
26 January 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481551
21 November 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1603702
17 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076149
7 November 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376821
24 February 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1046367
22 December 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 813722
17 November 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1412002
20 July 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1101282
2 June 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 803976
20 January 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 789969
18 November 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1368932
20 August 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 158318
19 June 1998 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 794039
19 May 1998 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1126235
11 February 1998 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 776686
25 November 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441321
18 November 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1110633
29 September 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 781111
15 May 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1098757
8 April 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1098182
27 February 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1102609
21 November 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1407794
24 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087146
24 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 690456
16 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1081120
5 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 120690
5 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 201405
21 December 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182914
14 November 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367561
26 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880097
13 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186831
30 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1143508
16 December 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1150081
28 November 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471318
30 November 1993 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1159256

Deficiency record · 63

Lifesaving
Issued 7 November 2001 Resolved
Provide the following rpts to OCMI: 3rd party lifeboat weight test results,liferaft inspection, copy of ABS survey (ABS A + ABS B only).
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Accommodation/Occupational Safety
Issued 17 November 1999 Resolved
PROVIDE BUNK LIGHT COVERS FOR ALL LIGHT FIXTURES WITHIN ACCOMMODATION SPACES.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 17 November 1999 Resolved
RENEW 300 GALLON AIR RECIVER TANK LOCATED ON AFT STBD SIDE OF SUB-STRUCTUREDECK UNDER RIG FLOOR. ***NOTE - TANK SHALL NOT BE USED DUE TO THE CONDITION OF EXTERIOR SHELL.***
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Lifesaving
Issued 17 November 1999 Resolved
CLEAN, RECOAT OR RENEW WITH INSERT IF DETERMINED AFTER CLEANING DETERIORATED BACK UP PLATE LOCATED ON STDB FORWARD LEG FOUNDATION IS WAISTED BEYOUND REPAIR. (SEE ABS CONDITION REPORT DATED 17NOV99)
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Construction/Loadline
Issued 17 November 1999 Resolved
WELD-UP HOLES ON WATERTIGHT SCUTTLE LOCATED ON MAIN DECK LEADING TO FIRE BOSS ROOM.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Accommodation/Occupational Safety
Issued 17 November 1999 Resolved
REPAIR LOWER SECTION OF WATERTIGHT DOOR COMBING. DOOR LOCATED ON UPPER DECK CONTROL ROOM AND ADJUST GALLEY WATER TIGHT DOOR.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Electrical
Issued 17 November 1999 Resolved
REPAIR/RENEW ELECTIRICAL STAND PIPE LOCATED ON PORT SIDE OF DRILL FLOOR (SUB-ROOM FORWARD) AT DECK LEVEL.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Accommodation/Occupational Safety
Issued 17 November 1999 Resolved
RENEW BROKEN PORT HOLE GLASS ON WATER TIGHT DOOR LEADING TO ROUSTABOUT LIVING QUARTERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Electrical
Issued 17 November 1999 Resolved
REPAIR EXHAUST LEAKS ON NO.2 AND NO.3 SHIP SERVICE GENERATORS PRIME MOVERS.(LEAK LOCATED ON RIGHT BANK OF ENGINES).
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Accommodation/Occupational Safety
Issued 17 November 1999 Resolved
RENEW BROKEN PORT HOLE GLASS LOCATED ON PORT SIDE OF AFT QUARTERS OF ROUSTABOUT LIVING QUARTERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 17 November 1999 Resolved
PROVIDE CO2 INSTRUCTIONS FOR PAINT LOCKER FIXED FIRE EXTINGUISHER SYSTEM.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Fire Fighting
Issued 18 November 1998 Resolved
REPAIR OR RENEW PORT AFT FAN DAMPER. (LOCATED ON MAIN DECK FOR MACHINERY SPACE)
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Electrical
Issued 18 November 1998 Resolved
LOCATE AND REMOVE GROUND FROM S/S GENERATOR DISTRIBUTION PANEL.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Lifesaving
Issued 18 November 1998 Resolved
RENEW RETRO TAPE ON #1 & #2 LIFEBOATS.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Lifesaving
Issued 18 November 1998 Resolved
REPAIR OR RENEW EYE WASH STATION LOCATED IN MUD PIT ROOM.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Electrical
Issued 18 November 1998 Resolved
PROVE PROPER OPERATION OF #1 S/S GENERATOR OVERSPEED AND LOW LUBE OIL SHUT DOWN.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Fire Fighting
Issued 25 November 1997 Resolved
RENEW AS ORIGINAL DOUBLED SECTION IN 12 INCH SALTWATER LINE IN MUDPUMP ROOMADJACENT TO P-TANK.
Condition: Unknown
Due 2 January 1998
Resolved 4 December 1997
Lifesaving
Issued 25 November 1997 Resolved
REPLACE EYEWASH STATIONS IN WAREHOUSE, MUD PIT ROOM, AND SHALE SHAKER HOUSE.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Engineering
Issued 25 November 1997 Resolved
LABEL REMOTE SHUTOFF CONTROLS FOR THE FOLLOWING LOCATIONS: EMERGENCY GENERATOR ENGINE AND FUEL SHUTDOWNS.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Accommodation/Occupational Safety
Issued 25 November 1997 Resolved
WHEN VENTILATION SHUTDOWN IS ENERGIZED, PROVE PROPER OPERATION OF WATERMAKER ROOM EXHAUST FAN.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Engineering
Issued 25 November 1997 Resolved
PROVE PROPER OPERATION OF REMOTE FUEL OIL SHUTDOWN.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Construction/Loadline
Issued 25 November 1997 Resolved
REPAIR HOLE IN MUD PIT BULKHEAD, INBOARD SIDE.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Electrical
Issued 25 November 1997 Resolved
MOUNT AND RELABEL CONTROLLER FOR "BLACK MAGIC" PIT IN MUD PIT ROOM.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Electrical
Issued 25 November 1997 Resolved
PROVIDE BLANK FOR LOAD CTR "LCG" PANEL IN WATERMAKER ROOM.
Condition: Unknown
Due 25 November 1997
Resolved 4 December 1997
Electrical
Issued 25 November 1997 Resolved
LABEL CONTROLS IN SACK ROOM ADJACENT TO GAITRONICS BOX AND FORKLIFT RECHARGE AREA
Condition: Unknown
Due 2 January 1998
Resolved 4 December 1997
Accommodation/Occupational Safety
Issued 25 November 1997 Resolved
MOVE HOSPITAL BUNK SO THAT IT IS ACCESSIBLE FROM BOTH SIDES.
Condition: Unknown
Due 2 January 1998
Resolved 4 December 1997
Engineering
Issued 25 November 1997 Resolved
PROVIDE SIGHT GLASS GUARDS FOR GEAR OIL TANK IN MUD PUMP ROOM UP TO PIT ROOM
Condition: Unknown
Due 2 January 1998
Resolved 4 December 1997
Accommodation/Occupational Safety
Issued 25 November 1997 Resolved
HYDRO-TEST THE O2 BOTTLE IN THE HOSPITAL SPACE.
Condition: Unknown
Due 2 January 1998
Resolved 4 December 1997
Construction/Loadline
Issued 21 November 1996 Resolved
REPLACE FIRST OUTBOARD STIFFENER STBDSIDE UNDERNEATH THE DRILL FLOOR.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Lifesaving
Issued 21 November 1996 Resolved
REPAIR HELODECK SKIRTING AFT.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Fire Fighting
Issued 21 November 1996 Resolved
REPLACE TWELVE FOOT FOG APPLICATOR ON HELODECK.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Engineering
Issued 21 November 1996 Resolved
REPLACE ALL FLAME SCREENS ON GOOSENECK VENTS TO ENGINEROOM LUBE OIL STORAGETANK.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Lifesaving
Issued 21 November 1996 Resolved
POST AT MAINDECK LEVEL LAUNCHING INSTRUCTIONS AT ALL LIFERAFT STATIONS.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Construction/Loadline
Issued 21 November 1996 Resolved
PROVE PROPER OPERATION OF BOTH BILGE PUMPS.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Lifesaving
Issued 21 November 1996 Resolved
PROVIDE INTERIOR LIGHTING IN BOTH LIFEBOATS.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Construction/Loadline
Issued 21 November 1996 Resolved
REPLACE ALL WASTED STIFFENERS ON SHAKER HOUSE OVERHEAD. DO NOT CARRY ANY CARGO ON TOP OF SHAKER HOUSE UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Electrical
Issued 14 November 1995 Resolved
PROVIDE SECURE BRACKETS TO HOLD EMERGENCY EXIT LIGHTS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Accommodation/Occupational Safety
Issued 14 November 1995 Resolved
INSTALL PRSSURE RELIEF VALVES ON SANITARY AND POTABLE WATER TANKS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
INSTALL EXPLOSION PROOF CABLE GLANDS (EYS OR BICC) ON MUDPIT FAN STARTER AND ON #2 PIT AGITATOR.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Fire Fighting
Issued 14 November 1995 Resolved
ENSURE ALL PORTABLE FIRE EXTINGUISHERS ARE LOCATED IN ACCORDANCE WITH ABS APPROVED FIRE CONTROL PLAN ( CO2 EXTINGUISHERS WHERE CO2 EXTINGUISHERS REQUIRED). ENSURE ALL PORTABLE EXTINGUISHERS HAVE THE PROPER BRACKETS FOR THAT EXTINGUISHER (NO FREE STANDING EXTINGUISHERS).
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
INSTALL SELF CLOSING DOOR DEVICES ON MUDPIT DOORS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Engineering
Issued 14 November 1995 Resolved
REPAIR LEAKY FUEL OIL VALVE ON GENERATOR DAY TANK SUPPLY LINE.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPAIR AND PROVE PROPER OPERATION OF OVERSPEED SHUTDOWN ON #1 GENERATOR PRIME MOVER.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPAIR OR REPLACE INOPERATIVE "E" LIGHTS IN EMERGENCY GENERATOR ROOM AND ATEXIT DOOR IN CHANGE ROOM (PORT).
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
INSTALL APPROVED SMOKE SIGNAL ON QUICK RELEASE RING BUOY STBD AFT AND REMOVE 150' LINE.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
REPLACE RETAINING LINE TO LIGHT FROM STBD STERN RING BUOY.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPAIR LIGHT FIXTURE IN AFT STBD STOREROOM ON MAIN DECK.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
PROPERLY REPAIR OR REPLACE MOTOR ON #2 MUD CLEANER.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPLACE PLASTIC TIES HOLDING WIRING IN OVERHEAD OF SHALE SHAKER AREA WITH PROPER STEEL BANDINGS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPLACE UNAPPROVED FITTINGS ON ELECTRICAL EQUIPMENT IN SHALE SHAKER AREA (AREA IS A CLASS I DIV. I AREA). FITTINGS IN USE APPROVED ONLY FOR CLASS I DIV. II AREAS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPLACE CRACKED LENSE ON EXPLOSION PROOF LIGHT AT DEGASSER UNIT.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REPLACE MISSING END CAPS ON EXPLOSION PROOF LIGHT OVER FORWARD SHALE SHAKERS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
REMOVE AND PROPERLY PLUG JUNCTION BOX WHERE DEAD END WIRE FOUND IN OVERHEADBETWEEN FWD AND AFT SHALE SHAKERS.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
CORRECT BOTTOM SCREW IN STROBE LIGHT HOLDER ON PORT BOW (STICKS OUT AND MAKES REMOVING LIGHT VERY HARD).
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
CLEAR ACCESS ROUTE TO PORT QUICK RELEASE RING BUOY AND MARK AREA WITH "KEEPCLEAR" MARKING. (SMOKE SIGNAL EXPIRES 11/95)
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
ATTACH PAINTER TO WEAK LINK ON PORT BOW LIFERAFT.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Lifesaving
Issued 14 November 1995 Resolved
PROPERLY SECURE PAINTER TO WEAK LINK AND REMOVE EXTRA METAL WEAK LINK FROM STBD BOW LIFERAFT.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Electrical
Issued 14 November 1995 Resolved
INSTALL EYS OR BICC TYPE FITTING ON EXLOSION PROOF LIGHT IN PAINT LOCKER.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Fire Fighting
Issued 14 November 1995 Resolved
PROVIDE POSITIVE CLOSURE ON EXHAUST VENT ON PAINT LOCKER.
Condition: Unknown
Due 20 November 1995
Resolved 20 November 1995
Engineering
Issued 28 November 1994 Resolved
HYDROSTATICALLY TEST FUEL TRANSFER HOSE TO 1.5 X MAwp.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Electrical
Issued 28 November 1994 Resolved
PROVIDE STATEMENT OF FACT FROM FLAG STATE RE. ON PROPER OPERATION OF ALARMS AND SHUTDOWNS ON ALL MAIN GEN. PRIME MOVERS.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Lifesaving
Issued 28 November 1994 Resolved
PROVIDE BACK UP ALARM FOR FORKLIFT.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994
Lifesaving
Issued 28 November 1994 Resolved
PROVIDE PROOF OF PROPER OPERATION OF BREATHING AIR SYSTEM FOR WATERCRAFT LIFEBOATS.
Condition: Unknown
Due 28 November 1994
Resolved 28 November 1994

Ownership record