MAURY USCG vessel records Sign in
← All vessels

CALLISTO

CALLISTO is a 1993 freight ship. The Coast Guard has recorded 19 inspections since 1995, most recently in May 2005, along with 13 deficiencies and 1 operational control.

Records from 1995 to 2005. Most recent: inspection, 15 May 2005.

Built
1993
Last inspected
15 May 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9073402 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
398736
Flag
PANAMA
—
Maury page id
psix-398736

Inspections, by type

…with no type recorded12
Years with a record 10 calendar years (1995–2005)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it8024 - Dead Weight, Ton
7316 - Regulatory (Subpart C or D), Gross Ton
4812 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

FRISCO Commercial Fishing Vessel · MISLE 71237 · 15 June 2000 · activity 34120

Inspection history · 19

15 May 2005 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2360103
7 March 2005 Deficiency Check · ISPS III Exam · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2304775
17 June 2004 Annual Inspection · MTSA/ISPS Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2101181
22 March 2004 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2028864
16 July 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1847888
22 May 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1798762
30 July 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1654408
29 July 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1653816
10 May 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1614819
4 May 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289583
28 September 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 282301
15 June 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 34120
17 April 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 276911
24 January 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 273870
9 July 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 430428
14 January 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 424407
10 September 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 420180
26 February 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 400919
13 June 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 497493

Deficiency record · 13

Lifesaving › Lifeboat › Markings
Issued 17 June 2004 Resolved
Reflective tape on both lifeboats needs to be replaced. Tape's reflective surface is worn off. Cite: LSA CODE Ch. 1 Reg 1.2.2.7 LEGACY COMPONENT DESC: Markings
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 July 2004
Resolved 7 March 2005
Resolution: MSO Philadelphia personnel boarded vessel and confirmed new retro-reflective tape has been applied to lifeboats.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 17 June 2004 Resolved
Ship's Lifeboats had a total of (05) wasted food rations. Replace (05) to be in compliance. Cite: LSA CODE Ch. 4 Reg 4.4.8.12 LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2004
Resolution: Recieved reciept via facsmile. Master attested to purchase of 5 lifeboat food ration(s).
Engineering › Freshwater System (air cooling)
Issued 22 May 2003 Resolved
VESSEL'S COOLING WATER SUPPLY LINE (IN ENGINE ROOM, PORT SIDE, OUTBOARD OF MSD UNIT) FOR DECK WINCHES WAS SOFT PATCHED OVER A LEAK, A VIOLATION OF SOLAS 74/78 CHII-1 REG 26/1. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 June 2003
Resolved 16 July 2003
Resolution: Cooling water supply line was permanently repaired.
Engineering › Steam System (auxiliary)
Issued 22 May 2003 Resolved
VESSEL'S STEAM WATER RETURN LINE (STARBOARD SIDE OUTBOARD OF #1 S/S GEN) FROM SHIP'S BOILER HAS SOFT PATCH OVER LEAK ON ELBOW, A VIOLATION OF SOLAS 74/78 CHII-1 REG 26/1 AND REG 33/1. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 June 2003
Resolved 16 July 2003
Resolution: Steam water return line was permanently repaired.
Documentation › Logs/Records
Issued 10 May 2002 Resolved
VESSEL NOT FOLLOWING GARBAGE MANAGEMENT PLAN (GARBAGE DISCHARGED ASHORE NOT LOGGED (VSL DOES HAVE RECEIPTS)). CORRECT PRIOR TO 90 DAYS. LEGACY COMPONENT DESC: Garbage Recordkeeping
Condition: Unknown
Due 10 August 2002
Resolved 29 July 2002
Resolution: Vessel is now correctly logging garbage being sent ashore and keeping reciepts of that.
Navigation › Piloting/Steering
Issued 10 May 2002 Resolved
CHARTS NOT CURRENTLY CORRECTED IAW 33 C.F.R. 164.33 (a)(1)(ii). FAX MSO COPY OF RECEIPT OF PURCHASE FOR NOTICE TO MARINERS 12-18. LEGACY COMPONENT DESC: Marine Charts
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2002
Resolution: AGENT FAXED RECEIPT OF PURCHASE OF NTM 12-19 TO MSO PHILADELPHIA.
Navigation
Issued 4 May 2001 Resolved
U.S. CHARTS 12214, 12304, 12311 WERE NOT CURRENTLY CORRECTED. U.S. COAST PILOT VOLUME III AND U.S. LIGHT LIST VOLUME II WERE NOT CURRENTLY CORRECTED. DEFICIENCY SHOULD BE CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 4 May 2001
Resolved 5 May 2001
Construction/Loadline
Issued 28 September 2000 Resolved
LOADLINE NEEDS TO BE A CONTRASTING COLOR TO HULL OF SHIP. _x001C_ ILLC 66 ANNEX I/9
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Lifesaving
Issued 28 September 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Fire Fighting
Issued 28 September 2000 Resolved
PROVIDE APPROPRIATE SIZED WASHERS FOR INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 4 May 2001
Resolved 4 May 2001
Fire Fighting
Issued 10 September 1998 Resolved
RELEASE VALVE ON FIXED CO2 #1 PILOT(STARTER) BOTTLE CORRODED/FROZEN IN PLACE. SOLAS 2-2/21_x001C_ _x001C_ *REPAIR PRIOR TO NEXT US PORT.*
Condition: Unknown
Due 14 January 1999
Resolved 14 January 1999
Lifesaving
Issued 26 February 1997 Resolved
PRIOR TO DEPARTING PORT OF TAMPA, UPDATE VESSEL MUSTER LIST AND SOLAS TRAINING MANUAL.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Lifesaving
Issued 26 February 1997 Resolved
PRIOR TO DEPARTING PORT OF TAMPA, PROPERLY CONDUCT A FIRE AND A ABANDON SHIP DRILL TO USCG INSPECTORS SATISFACTION.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997

Ownership record