SAILOR'S DELIGHT II

SAILOR'S DELIGHT II is a passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1993, most recently in May 2026, along with 23 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 1993 to 2026. Most recent: inspection, 27 May 2026.

Built
Not recorded
Last inspected
27 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

398827
Flag
UNITED STATES
—
Maury page id
psix-398827

Inspections, by type

Years with a record 23 calendar years (1993–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

27 May 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8368089
17 April 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8351417
27 October 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8258382
3 October 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8245944
25 June 2024 COI Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7941959
24 June 2024 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7938951
15 April 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6939595
13 June 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6712470
4 June 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6427953
23 May 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6153049
24 May 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5885295
3 June 2014 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4881147
9 May 2012 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4306554
28 September 2010 Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 3860192
11 September 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2775323
25 April 2005 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2383767
27 August 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2191538
19 June 2001 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1067920
18 October 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1055143
26 May 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049441
20 May 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798577
22 May 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 792064
27 May 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108184
23 May 1996 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1184996
18 October 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 872049
24 May 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 867003
17 April 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 833262
7 February 1995 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1147155
12 July 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 866771
27 May 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862865
24 May 1994 Hull Examination · Plan Review "T" Boat
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 860285
17 December 1993 Initial Construction-Excluding Oversight
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 850241

Deficiency record · 23

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2025 Resolved
Electrical equipment exposed to corrosive environments must be of suitable construction and corrosion-resistant. Battery terminal connections are severely corroded and wasted. Replace connections to the satisfaction of MI. 46CFR46CFR183.210(c) 701C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2026
Resolution: Received satisfactory evidence for the replacement of battery terminals
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 October 2025 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Label location equipped with child sized life jackets. 46CFR180.78(5) 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2025
Resolution: Proof of proper labeling was provided
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets. Vessel was missing one fire bucket. Provide proof of additional fire bucket to the satisfaction of MI. 46CFR181.610 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2025
Resolution: Proof of additional fire bucket was provided
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 October 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not conduct an annual inspection during the required time frame. Vessel must conduct an annual inspection. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2025
Resolution: Conducted annual COI on 10/27/2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Vessel's fuel shut-off valve cannot be turned/moved because it is seized. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2024
Resolution: Received satisfactory evidence via photos. See attached.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2024 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Vessel is missing one (1) 10:BC portable extinguisher for the operating station. Procure a portable extinguisher that complies with regulations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 July 2024
Resolution: Received satisfactory evidence via photos. O/O double clamped hoses. See attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 June 2024 Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable;(2) The clamps must be of a corrosion resistant metallic material (3)The clamps must not depend on spring tension for their holding power and (4) Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage. Flexible hoses for the outboard engine consisted of only 1 clamp. Double clamp the hoses as specified in the regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 July 2024
Resolution: Received satisfactory evidence via photos. O/O double clamped hoses. See attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2024 Resolved
In a vessel of 12 meters or more in length but less than 50 meters in length: (i) A masthead light, 5 miles; except that where the length of the vessel is less than 20 meters, 3 miles; (ii) A sidelight, 2 miles; (iii) A sternlight, 2 miles; (iv) A towing light, 2 miles; Replace the sternlight and masthead lights with appropriate fixtures that emit the correct intensity for optimal visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 July 2024
Resolution: Received satisfactory evidence via photos. See attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 June 2024 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle, a vessel of 20 meters or more in length shall be provided with a bell in addition to a whistle, and a vessel of 100 meters or more in length shall, in addition, be provided with a gong, the tone and sound of which cannot be confused with that of the bell.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2024
Resolution: vessel installed sound signal. See photos.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 June 2024 Resolved
Each flare carried to meet this section must be stowed in one of the following: A portable watertight container marked as required by 185.614 "DISTRESS SIGNALS". Flares on board were not properly stowed. Stow flares in a portable watertight container.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 July 2024
Resolution: Vessel has new watertight container for distress signals
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. There were only 19 adult PFDs onboard vice 20 as specified in their COI. Procure an additional PFD with correct specifications or vessel will be limited to 19 adult passengers.
Action required: 705 - Other - as specified
Resolved 1 July 2024
Resolution: Received satisfactory evidence via photos. See attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 June 2024 Resolved
Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Vessel did not have a fuel filter strainer bowl.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 11 July 2024
Resolution: Received photographic evidence of suitable fuel strainer installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2017 Resolved
46CFR180.70: Make waterlight operable. Limited to daylight operations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 24 July 2017
Resolution: Attended vessel and verified proper operation of waterlight.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 3 June 2014 Resolved
Vsl must double Clamp fuel hose connections. At tank and at engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 6 June 2014
Resolution: Clamps installed. ALL SAT
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 3 June 2014 Resolved
Vessel has a total of 02 BII on board. Regs state that vessel must have 02 B-II and 01 B-I. 46CFR181.30-1 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 27 June 2014
Resolution: Vsl has installed portable FF extinguishers per 46CFR181.30-1 (a)
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 3 June 2014 Resolved
Vessel must repair/replace 12 adult / 12 child PFD's due to UNSAT Retro. Vessel is restricted to carrying 12 adult and 01 child until PFD's are either repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2014
Resolved 6 June 2014
Resolution: Retro replaced on PFD''S. ALL SAT.
Engineering › Fuel Oil Service System › Valve, Control
Issued 3 June 2014 Resolved
Label fuel shut off with direction of open/closure.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 6 June 2014
Resolution: Rep Labeled fuel shut off with direction of open/closure. ALL SAT
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 3 June 2014 Resolved
1. Post/provide copy of vessels drug/alcohal policy. 2. Provide proof of current DAPI Crew list. 3. Provide copy of DAPI MIS report for CY 2013.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 6 June 2014
Resolution: Items 1-3 inpsected/ onboard ALL SAT
Navigation › Piloting/Steering › Marine Charts
Issued 3 June 2014 Resolved
Vessel must maintain current/corrected charts of Area of Operation. 46 CFR182.455 (b) (4). Vessel has NO charts on board. Rep states that there are no available charts for his area. Consulted with STA Philly and recommeded rep contact www.navioncis.com. They provide charts for waterways not charted by NNOA.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 29 July 2014
Resolution: Per CID vessel is exempt from 46 CFR182.455 (b) (4). Special note added in veesel MISLE file.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 June 2014 Resolved
Vessel ring bouy missing retro.
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 6 June 2014
Resolution: Retro installed on ring bouy. ALL SAT
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 August 2004 Resolved
Provide a new battery box.
Condition: Placed in Improper Service
Due 27 September 2004
Resolved 28 September 2004
Resolution: Provided new box.
Engineering
Issued 26 May 2000 Resolved
PROVIDE PLANS FOR APPROVAL TO RETROFIT EXISTING FUEL TANK OR REPLACE FUEL TANK TO BRING 25 GALLON FUEL TANK INTO COMPLIANCE WITH 46CFR182.445(e) TO EXTEND FUEL FILL PIPE TO WITHIN 1/2 OF THE DIA. OF THE FILL PIPE TO THE BOTTOM OF THE TANK AND ENSURE THE TANK IS PROPERLY VENTED.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 27 May 1994 Resolved
PRIOR TO CARRYING MORE THAN THIRTY-FOUR (34) PASSENGERS, PROVIDE TWO (2) ADDITIONAL USCG-APPROVED TYPE I ADULT-SIZE LIFE PRESERVERS.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994