PARAGON MSS2

PARAGON MSS2 is a 1975 mobile offshore drilling unit. The Coast Guard has recorded 26 inspections since 1993, most recently in August 2016, along with 69 deficiencies.

Records from 1993 to 2016. Most recent: inspection, 10 August 2016.

Built
1975
Last inspected
10 August 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7347433 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
399046
Flag
LIBERIA
—
Maury page id
psix-399046

Inspections, by type

…with no type recorded10
Years with a record 13 calendar years (1993–2016)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it10958 - Convention (Subpart B), Gross Ton
7339 - Regulatory (Subpart C or D), Gross Ton
3287 - Convention (Subpart B), Net Ton
6435 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TROJAN TIDE Offshore Supply Vessel · MISLE 48231 · 17 January 1996 · activity 67812SHUT OUT Offshore Supply Vessel · MISLE 49387 · 30 June 1995 · activity 81371TROJAN TIDE Offshore Supply Vessel · MISLE 48231 · 26 March 1995 · activity 151TROJAN TIDE Offshore Supply Vessel · MISLE 48231 · 12 February 1994 · activity 90690

Inspection history · 26

10 August 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5974526
26 June 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2703353
3 May 2005 COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2353867
8 June 2004 COC-MODU Annual
Type not classified · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2092581
5 June 2003 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1810090
11 May 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818185
14 May 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415178
8 January 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1120692
8 January 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1126252
31 December 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 783387
20 November 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445295
7 November 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1108099
11 July 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 41012
13 February 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110128
7 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098130
29 November 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374795
17 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67812
6 December 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414545
30 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 81371
26 March 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 151
15 December 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454138
9 August 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 679648
13 July 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 61944
12 February 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 90690
1 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162408
17 December 1993 Deficiency Check · Letter of Compliance (Initial/Renewal)
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455118

Deficiency record · 69

Fire Fighting › Ventilation Systems › Fans
Issued 5 June 2003 Resolved
Demonstrate operation of means for stopping ventilation fans serving machinery and working spaces as per the 1979 IMO MODU Code 9.10.1. These means shall be capable of being operated from outside such space in case of fire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Proved proper operation of securing ventilation from outside space.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 June 2003 Resolved
Demonstrate a means for closing all ventilators, annual spaces around funnels and other openings to machinery and working spaces as per the 1979 IMO MODU Code 9.10.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the closing of all ventilators, annual spaces around funnels and other openings to machinery and working spaces.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 5 June 2003 Resolved
Prepare and install a directory of circuits for all elctrical distribution panels.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the installation of circuit directory cards in all distribution panels.
Electrical › Lighting (emergency)
Issued 5 June 2003 Resolved
Install and prove operation of emergency lighting under transitional source of power which provides adequate illumination for the entire launching process of lifeboats and liferafts from the stowed position to the water as required by IMO MODU Code 5.3.4.1 and NVIC 3-88 enclosure (1) paragraph 7.I. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Installed emergency lighting for liferafts and determined that the transitional source of lighting was sufficient for the launching of the lifeboats.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 June 2003 Resolved
Install additional emergency lighting powered under the transitional source of power which provides adequate illumination of escape routes from the motor room, mud pump room and other service spaces as required by IMO MODU Code 5.3.4.1 and NVIC 3-88 enclosure (1) paragraph 7.I.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed a satisfactory operational test of emergency lighting under transitional power.
Electrical › Electrical Distribution System (emergency)
Issued 5 June 2003 Resolved
Prove operation of essential internal communication equipment under transitional source of power as required by IMO MODU Code 5.3.4.2 (i.e. general alarm, fire alarm, public address system, etc...) LEGACY COMPONENT DESC: General alarm, fire alarm, public address
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory test of all equipment under transitional power.
Documentation › Certificates/Documents
Issued 5 June 2003 Resolved
Provide proof that fire protection material, Polyspec Flex FR, has been tested in accordance with the FTP Code. LEGACY COMPONENT DESC: MODU Safety Certificate
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Received correspondence proving that the fire protection insulation material, polyspec Flex FR, complies with the FTP Code.
Fire Fighting › Ventilation Systems › Stairway Enclosure Ventilation
Issued 5 June 2003 Resolved
Ventilator openings shall be provided with efficient and accessible closing devices as required by ICLL, 1966 Regulation 19.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Withnessed the installing of steps providing access to the ventilation closures.
Operations/Management › Drills/Instruction
Issued 5 June 2003 Resolved
Conduct satisfactory fire and abandon ship drill in the presence of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Fire/Abandon Ship
Action required: 705 - Other - as specified
Due 10 June 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory fire and abandon ship drills.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 5 June 2003 Resolved
Provide evidence of tests and inspections of all oil transfer hoses as required by 46 CFR 155.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Received documentation for transfer hoses.
Operations/Management › Equipment Service/Testing
Issued 5 June 2003 Resolved
Provide for review lifesaving equipment maintenance records. LEGACY COMPONENT DESC: Lifesaving equipment maintenance records
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Reviewed lifesaving equipment maintenance records.
Operations/Management › Drills/Instruction
Issued 5 June 2003 Resolved
Provide for review emergency training and drill records. LEGACY COMPONENT DESC: Emergency training and drill records
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Reviewed emergency training and drill records.
Engineering › Bilge Water Management System › Interface Detector
Issued 5 June 2003 Resolved
Repair and prove operation of faulty ballast indicator panel system lights in the ballst control room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory test of ballast indicator panel system lights.
Fire Fighting › Fire Pumps
Issued 5 June 2003 Resolved
Repair and prove proper operation of remote fire pump start/stop switch located on the ballast control system console in the ballast control room. LEGACY COMPONENT DESC: Remote start/stop switch
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory test of the remote fire pump start/stop switch located on the ballast control system console in the ballast control room.
Fire Fighting › Fire Main › Condition
Issued 5 June 2003 Resolved
Prove operation of fire main system and all fire pumps from each local and remote starting station.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory operation of fire main system and all fire pumps from local and remote starting locations.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2003 Resolved
Prove operation of navigational lights and signals.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Withnessed satisfactory test of all navigation lights.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 5 June 2003 Resolved
Prove operation of remote shutdowns for fuel oil transfer pumps, oil fuel unit pumps and other similar pumps.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory test of all remote shutdowns.
Engineering › Bilge Water Management System
Issued 5 June 2003 Resolved
Prove operational test of bilge water level detection and automatic bilge pump operation for each column. LEGACY COMPONENT DESC: operational test
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory test of bilge level detection and bilge system.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 June 2003 Resolved
Remove locking device for SCR CO2 compartment watertight door. LEGACY COMPONENT DESC: watertight door
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the removal of locking device on SCR CO2 watertight door.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2003 Resolved
Properly support and secure electrical cable leading from receptacle on starboard motor room bulkhead to air dryers.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Properly secured cable.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2003 Resolved
Properly support and secure electrical cables for NO.1 & NO.7 generator prime mover alarm light.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the proper installation of cables.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2003 Resolved
Properly support and secure electrical cable located on the forward pump room bulkhead.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the proper installation of cable located on the forward pump room bulkhead.
Engineering › Diesel Engine (auxiliary)
Issued 5 June 2003 Resolved
Install piping supports for generator prime mover cooling water and fire main piping located starboard side motor room bulkhead. LEGACY COMPONENT DESC: piping
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the installation of brackets for generator prime mover cooling water and fire main.
Electrical › Electrical Distribution System (service) › Busway
Issued 5 June 2003 Resolved
Remove dead ended cables in cable transits located on forward pump room bulkhead.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the removal of dead ended cable in the cable transits located on forward pump room bulkhead.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 June 2003 Resolved
Install cover for fluorescent light fixture located in mud pump room.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the installation of light fixture cover in mud pump room.
Fire Fighting › Miscellaneous Items
Issued 5 June 2003 Resolved
Provide audible and visual signal for general and fire alarms in high ambient noise areas (i.e. motor room, emergency generator room, air compressor room, pump room). LEGACY COMPONENT DESC: General alarm
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed satisfactory test of audible signal in all spaces and determined that audible signal was loud enough not requiring a visual signal for these spaces,
Stability › Watertight Integrity
Issued 5 June 2003 Resolved
Install approved cable penetration material to cable penetrations to moon pool and mud pump bulkhead. LEGACY COMPONENT DESC: Cable penetrations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the installation of approved watertight cable transits.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2003 Resolved
Re-route, properly support and secure electrical cable from 120 VAC distribution panel located in the emergency generator room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the proper installation of cable in emergency generator room.
Fire Fighting › International Shore Connection › Connection
Issued 5 June 2003 Resolved
Provide for examination required international shore connection and standard discharge connection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Vessel representative provided an international shore connection and standard discharge connection.
Stability › Watertight Integrity
Issued 5 June 2003 Resolved
Repair and prove operation of watertight door located on bulkhead separating mud pump room and moon pool area. LEGACY COMPONENT DESC: Quick acting watertight door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the proper operation of watertight door separating mud pump room and moon pool area.
Fire Fighting › Ventilation Systems
Issued 5 June 2003 Resolved
Prove operation of loss of ventilation alarms. LEGACY COMPONENT DESC: Loss of ventilation alarm
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Witnessed the proper operation of loss of ventilation alarm in the mud pump room, sack room, and occumadation stairway.
Documentation › Certificates/Documents › MODU Safety Certificate
Issued 5 June 2003 Resolved
Make available for inspection drill floor, shale shaker area, and mud pits spaces.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 10 June 2003
Resolution: Satisfactory inspected drill floor, shale shaker area, and mud pits.
Electrical
Issued 14 May 1999 Resolved
REPAIR AND CONDUCT SATISFACTORY TEST OF REVERSE POWER RELAY FOR #3 MAIN GENERATOR, AND LOG.
Condition: Unknown
Due 28 May 1999
Resolved 17 May 1999
Documentation
Issued 14 May 1999 Resolved
IMPLEMENT 46 CFR 109.213 REGULATIONS FOR TRAINING CREW AND INDUSTRIAL PERSONNEL.
Condition: Unknown
Due 14 June 1999
Resolved 17 May 1999
Fire Fighting
Issued 14 May 1999 Resolved
MAKE ALL FIRE DOORS LEADING TO GALLEY SELF CLOSING AND REMOVE ALL HOLDBACKS.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Lifesaving
Issued 14 May 1999 Resolved
REPLACE ALL LIFEBOAT DAVIT BUMPER PADS.
Condition: Unknown
Due 14 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 20 November 1997 Resolved
Reinstall the hazardous location boundary doors to open INTO the mud pit compartment from the moon pool area; reinstall boundary doors to open INTO the SCR/motor room from the mud pit room (zone 1 to zone 2 and zone 2 to unclassified zone transitions respectively) iaw 1979 IMO MODU Code.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Documentation
Issued 20 November 1997 Resolved
Provide copies of valid ABS endorsed loadline certificate and Panamanian IMO MODU Code certificate when all ABS outstanding annual survey comments have been satisfactorily resolved. Must be completed prior to expiration date of current year's (1996/197) endorsement.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Construction/Loadline
Issued 20 November 1997 Resolved
Provide fume-tight (and weather-tight/water-tight where applicable) bulkhead and/or deck penetration enclosures/sealing arrangements for all improperly sealed electrical cable, piping, and BOP chord penetrations between hazardous location divisions (Div 1 to Div 2/Div 2 to unclassified)
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Fire Fighting
Issued 29 November 1996 Resolved
MAKE REPAIRS TO FIREFIGHTING EQUIPMENT IN ACCORDANCE WITH GULF WIDE SAFETY SYSTEMS, INC. REPORT, DATED 25SEP96.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996 Resolved
CONTINUANCE OF LETTER OF COMPLIANCE CONTINGENT UPON WEIGHT TESTS OF LIFEBOATS PRIOR TO 17AUG97.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Electrical
Issued 29 November 1996 Resolved
ADDRESS HISTORICAL PROCEDURE TO TURN-OFF OBSTRUCTION LIGHTS AT NIGHT DUE TOELECTRICAL SWITCH NOISE IN CONTROL ROOM. SECURE NOISE OR INSTATE POLICY REQUIRING OBSTRUCTION LIGHT OPERATION AT ALL TIMES OF REDUCED VISIBILITY.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Documentation
Issued 29 November 1996 Resolved
PLACE CARGO SHIP SAFETY RADIO CERTIFICATE AND PANAMANIAN SAFE MANNING CERTIFICATE ON BOARD.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Lifesaving
Issued 29 November 1996 Resolved
PLACE WIND DIRECTION INDICATOR AND TAIL ROTOR WARNING SIGNS AT HELIPORT.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Documentation
Issued 29 November 1996 Resolved
PROVIDE COPY OF FULL TERM PANAMANIAN MODU SAFETY CERTIFICATE, INTERNATIONALOIL POLLUTION PREVENTION CERTIFICATE AND LOADLINE CERTIFICATE. CONTINUANCE OF LOC CONTINGENT UPON COMPLIANCE.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996 Resolved
PLACE PROPER INSTRUCTIONS AT LIFERAFT STATIONS. PROPERLY STENCIL AND STOW LIFERAFTS. REPAIR LIGHTING AT LIFERAFT STATIONS.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Lifesaving
Issued 29 November 1996 Resolved
CAPACITY OF MODU CREW LIMITED TO 80 PERSONS WHILE LIFERAFT NO. 5 IS BEING SERVICED AND LIFEJACKET LIGHTS ARE ON ORDER.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Fire Fighting
Issued 29 November 1996 Resolved
ADDRESS FIREMAN'S OUTFIT DEFICIENCIES: REPLACE FLASHLIGHTS, LIFELINES AND BOOTS. HYDROSTATICALLY TEST OUTDATED SCBA BOTTLES. CALIBRATE 02/LEL MONITORS. LABEL STOWAGE ROOMS/CONTAINERS.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Electrical
Issued 29 November 1996 Resolved
LABEL EMERGENCY LIGHTING THROUGHOUT RIG.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996 Resolved
PROPERLY MOUNT AND ARRANGE LIFE RINGS, PER FIRE CONTROL/LIFESAVING PLAN.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996 Resolved
MAKE REPAIRS AND REPLACE EQUIPMENT TO ENSURE ALL LIFEBOATS ARE EQUIPPED IN ACCORDANCE WITH SOLAS 74, CHAPTER III.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Construction/Loadline
Issued 29 November 1996 Resolved
REPLACE WASTED DECK GRATING ON TOP OF C-COLUMN, ADJACENT TO ANCHOR WINCH, AND AT WALKWAY TO E-COLUMN, ADJACENT TO STARBOARD LIFERAFT.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Fire Fighting
Issued 29 November 1996 Resolved
INSTALL VALVE IN AIR LINE TO PAINT LOCKER, OUTSIDE OF LOCKER ADJACENT TO FIXED CO2 SYSTEM. PLACE "SECURE AIR SUPPLY VALVE" IN FIXED FIREFIGHTING SYSTEM INSTRUCTIONS.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996 Resolved
TRAIN CREW ON PROPER ABANDONMENT PROCEDURE FROM LIFERAFTS AND PROPER USE/LIMITATIONS OF SELF CONTAINED BREATHING APPARATUS (SCBA).
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Electrical
Issued 29 November 1996 Resolved
MAKE REPAIRS AND/OR REPLACE WASTED SECTIONS OF S/W COOLING PIPING TO GENERATORS.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Lifesaving
Issued 29 November 1996 Resolved
RENEW 47 LIFE PRESERVER LIGHTS.
Condition: Unknown
Due 3 December 1996
Resolved 3 December 1996
Electrical
Issued 29 November 1996 Resolved
REPAIR CABLE TO OVERSPEED SHUT DOWN ON GENERATOR NO. 3.
Condition: Unknown
Due 29 November 1996
Resolved 29 November 1996
Construction/Loadline
Issued 6 December 1995 Resolved
REPAIR BILGE ALARM IN COLUMN "C"
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Electrical
Issued 6 December 1995 Resolved
TROUBLESHOOT AND REPAIR GROUND INDICATION ON EMERGENCY GENERATOR PANEL.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Electrical
Issued 6 December 1995 Resolved
ADJUST OVERSPEED SENSING DEVICE ON EMERGENCY GENERATOR AND PROOF TEST PROPER OPERATION OF AUTO-BUS TRANSFER.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Engineering
Issued 6 December 1995 Resolved
PROPERLY LABEL EMERGENCY FUEL SHUT-OFF FOR DAY TANK.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Electrical
Issued 6 December 1995 Resolved
PROVE PROPER OPERATION OF PURGE LOSS ALARM ON TV MONITOR FOR MUD LOGGING UNIT.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Documentation
Issued 6 December 1995 Resolved
PROVIDE COPY OF FULL TERM PANAMANIAN MODU SAFETY CERTIFICATE.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Accommodation/Occupational Safety
Issued 6 December 1995 Resolved
COMPLETE NDT OF ALL PRESSURE VESSELS TO THE SATISFACTION OF THE FLAG ADMINISTRATION AND SUBMIT REPORT TO [name withheld].
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Fire Fighting
Issued 6 December 1995 Resolved
REPAIR GENERAL ALARM BELL IN COLUMN "A"
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Electrical
Issued 17 December 1993 Resolved
MAKE ALL PURGE SYSTEMS ON DRILL FLOOR OPERATIONAL AND TEST ALARMS OF SAME PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 28 December 1993
Resolved 28 December 1993
Deck/Cargo
Issued 17 December 1993 Resolved
LOAD TEST PORT FORWARD CRANE UPON COMPLETION OF REPAIRS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 December 1993
Resolved 28 December 1993
Lifesaving
Issued 17 December 1993 Resolved
REPAIR AND TEST OPERATION OF GENERAL ALARM BELLS IN THE FOLLOWING AREAS: 1. PILOT HOUSE 2. COLUMN E PUMP ROOM 3. M.S.D. SPACE
Condition: Unknown
Due 28 December 1993
Resolved 28 December 1993
Engineering
Issued 17 December 1993 Resolved
REPAIR AND TEST OPERATION OF ALL GENERATORS' REVERSE CURRENT RELAYS.
Condition: Unknown
Due 28 December 1993
Resolved 28 December 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.