MAURY USCG vessel records Sign in
← All vessels

MOSOR

MOSOR is a 2001 freight ship. The Coast Guard has recorded 17 inspections since 2002, most recently in August 2014, along with 21 deficiencies and 2 operational controls.

Records from 2002 to 2014. Most recent: inspection, 15 August 2014.

Built
2001
Last inspected
15 August 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9191527 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
CROATIA
—
Maury page id
psix-39919

Inspections, by type

…with no type recorded4
Years with a record 8 calendar years (2002–2014)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13770 - Convention (Subpart B), Net Ton
24533 - Convention (Subpart B), Gross Ton
42584 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

15 August 2014 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4955517
23 June 2014 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4891104
23 September 2010 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3851989
24 March 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3700834
14 July 2009 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3534397
3 November 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3356606
22 May 2008 MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3213335
5 October 2005 Random ISPS/MTSA/PSC · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2508663
28 September 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2503400
3 June 2005 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2376230
17 June 2004 PII Safety Exam · MTSA/ISPS Verification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2100369
16 June 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2100791
16 June 2004 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2108513
31 October 2003 Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1937265
27 April 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1781213
18 September 2002 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1675465
17 September 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1679441

Deficiency record · 21

Electrical › Electric Generation Source (emergency) › Generator
Issued 23 June 2014 Resolved
Provide for satisfactory start-up of vessel's emergency generator utilizing secondary independent start-up system (hydraulic) in accordance with the cited SOLAS regulation.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2014
Resolved 24 June 2014
Resolution: Witnessed satisfactory operational test of the emergency generator''s secondary independent start-up system. All sat
Lifesaving › Inflatable Liferafts › Float Free
Issued 24 March 2010 Resolved
0620 Both life rafts found missing weak link. Additionally starboard life raft is missing tie down shackle and is not secured for sea. SOLAS III 14 4.1 17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: Both life rafts HRU''s were replaced with new from local supplier West Coast Supply.
Lifesaving › Rescue Boat › Propulsion Transmission
Issued 24 March 2010 Resolved
0615 Rescue boat cooling adapter has been permanently affixed restricting the flow of seawater during use. In addition idle is not able to maintain consistent speed. SOLAS III 14 17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: Cooling adapter was removed and new manufactured parts have been ordered.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 March 2010 Resolved
1499 Seawater cooling line for ships machinery is severely wasted with multiple patches. This condition presents a potential for water ingress and loss of critical machinery. SOLAS II-1/26
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: Ships cooling line is to replaced in the first discharge port in Europe, not later than 30Apr10.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 March 2010 Resolved
0673 VHF radiotelephones were found inoperable and do not conform to performance standards. Address to the satisfaction of class. Maintenance reports indicate all radios were operational. SOLAS III/6 2.1.1 17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: VHF batteries were found to be bad and all replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 March 2010 Resolved
2040 The following discrepancies were found with the voyage plan: 1) Voyage plan is not being signed 2)Not berth to berth 3)Un corrected charts
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: Charts have been updated in witness of surveyor, voyage plan was updated to reflect berth to berth.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 24 March 2010 Resolved
1575 Echo depth sounders last recorded depth was several months ago and depth was off by 6 meters. Address to satisfaction of Class. 33CFR 164.35 (i) 17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: Echo depth sound is in proper working condition and printer has been repaired.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 24 March 2010 Resolved
0950 A portable battery charger is being used to charge emergency generator battery bank and is unable to maintain a full charge. Address to the satisfaction of class. SOLAS II-1 43.3.2 17ab
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2010
Resolved 26 March 2010
Resolution: The purchased battery charger has been mounted and installed for use.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 24 March 2010 Resolved
The Long Range Identification and tracking System has been installed but is not reflected on the SOLAS Radio Equipment certificate (FORM R). 17ab
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 March 2010
Resolved 26 March 2010
Resolution: According to the Croatian Register of Shipping. LRIT is only to be mentioned in Safety equipment record form E and not also in Safety Radio record Form R.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 22 May 2008 Resolved
No deficiency
Action required: 705 - Other - as specified
Due 22 June 2008
Resolved 28 May 2008
Resolution: Deficiency removed [name withheld]
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 June 2005 Resolved
0650 Replace the bridge wing lifebuoys and the self-igniting lights with class approved equipment. The lifebuoys are cracked and the lights do not work. SOLAS 74 AMD III/7.1 Rectify deficiencies prior to departure.
Action required: 705 - Other - as specified
Resolved 14 June 2005
Resolution: Received fax from [name withheld] stating the bridge wing lifebuoys and the self-igniting lights were replaced.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 June 2005 Resolved
1735 Remove the valve under the Oil Water Separator way valve. This valve is not listed on the bilge piping diagram. MARPOL 73/78 Annex I/8A.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 14 June 2005
Resolution: Received fax from [name withheld] stating the valve was removed and the piping was restored to condition as per original drawing.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 June 2004 Resolved
Vsl issued Letter of Deviation for inoperative Radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2004
Resolved 18 June 2004
Resolution: Necessary repairs made, vsl cleared to sail.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 17 June 2004 Resolved
Update the oil transfer procedures to comply with 33 CFR 155.750.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 June 2005
Resolution: Oil transfer procedures comply with 33 CFR 155.750
Documentation › Logs/Records › Oil Record Book
Issued 31 October 2003 Resolved
Commence making entries in to the Oil Record Book as per the instructions found in appendix III of Annex I of MARPOL 73/78. Where the quantity of contents retained is not recorded under the C-12-2 of 3 entries.
Action required: 705 - Other - as specified
Resolved 17 June 2004
Resolution: Proper entries into the Oil Record Book are being performed.
Fire Fighting › Combustible Materials › Ceilings
Issued 31 October 2003 Resolved
Remove spare gasoline to rescue boat from engine room & store in approved flammable liquid storage area. SOLAS 74 and I/11.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Recieved class report.
Stability › Water on Deck › Deck Plating
Issued 31 October 2003 Resolved
Remove fluid from duct keel. Determine source and permanently affixed label on the ARPA 33 C.F.R 164.38
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Recieved class report.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 31 October 2003 Resolved
Provide permanently affixed label on the ARPA 33 C.F.R 164.38.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2004
Resolution: Label properly affixed to ARPA.
Lifesaving › Emergency Outfit › Protective Clothing
Issued 31 October 2003 Resolved
Provide approved emergency escape breathing apparatus (EEBD) at Bridge station to replace EEBD now marked "Trainer". FSS Code 3/2.2. LEGACY COMPONENT DESC: EEBD
Action required: 15 - Rectify deficiencies by next port
Resolved 17 June 2004
Resolution: Proper EEBD provided at Bridge station.
Navigation › Piloting/Steering
Issued 31 October 2003 Resolved
Prove proper operation of the #2 steering system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Recieved class report
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 October 2003 Resolved
Repair main engine where leaking cooling water at #1 cylinder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Recieved class report.

Ownership record