MAURY USCG vessel records
← All vessels

MSC ROBERTA V

MSC ROBERTA V is a 1993 freight ship. The Coast Guard has recorded 9 inspections since 2017, most recently in August 2023, along with 3 deficiencies.

Records from 2017 to 2023. Most recent: inspection, 10 August 2023.

Built
1993
Last inspected
10 August 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 August 2023
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9038907
399267
Flag
LIBERIA
Maury page id
psix-399267

Documentation record

Tonnage as PSIX records it53815 - Convention (Subpart B), Gross Ton
67685 - Dead Weight, Metric Ton
88425 - Displacement, Metric Ton
23499 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

10 August 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7754657
2 April 2021 MARPOL Annex VI Survey · Ballast Water Examination · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7167399
21 June 2018 ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6448631
7 May 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6407915
19 April 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6394586
22 September 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6272376
8 July 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6201857
23 February 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6093361
22 February 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6092512

Deficiency record · 3

Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2018 Resolved
0520 - Lighting-Working Spaces - Electrical or other equipment which may constitute a source of ignition of flammable vapours shall not be permitted. PSCOs observed multiple light fixture in air compressor space were corroded and contained an accumalation of oil. - SOLAS74(2004CONS.) II-1 / 45.9.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2018
Resolved 7 May 2018
Resolution: Received submitted class report attesting to satisfactory repairs.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 April 2018 Resolved
0715 - The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention with in 02 min an audible alarm shall be automatically sounded throughout machinery spaces of category A. Smoke alarm above #2 generator did not produce audible alarm within 02 minutes. SOLAS74(1997CONS.) II-2 / 13.1.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 April 2018
Resolution: CODE 10c
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 22 September 2017 Resolved
1410-where remote control of propulsion machinery from the navigation bridge is provided, the speed, direction of thrust and if applicable the pitch of the propeller shall be fully controllable from the navigation bridge under all sailing conditions, including maneuvering. PSCO noted the vessel is not able to control astern thrust from the navigation bridge control. 74 SOLAS (04) II-I/31.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2017
Resolution: Magnetic switch S6 on reversing cylinder for no.4 fuel injection pump was defective. The s6 switch has been renewed with spare. Class conducted 12 dead slow ahead and dead slow astern from two air bottles and found operating satisfactory as required.

Ownership record