Inspection history · 37
23 March 2026
Vessel Attendance · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8332146
9 December 2025
Hull Examination · Internal Structural Exam · Vessel Attendance · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8273789
21 October 2025
In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8196777
24 March 2025
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8097155
25 September 2024
In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8012347
25 March 2024
Administrative Inspection · Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7884535
5 February 2024
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7846582
25 April 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7679404
13 March 2023
Administrative Inspection · Damage Survey · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7638338
11 March 2023
Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7655761
11 March 2023
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7657753
20 July 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7510424
20 July 2022
DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7510428
20 July 2022
Plan Review (Other than "T") · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7522493
30 March 2022
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7401886
15 March 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7455338
3 January 2022
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7375131
29 October 2021
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7343829
17 August 2021
In-Service Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7284012
17 August 2021
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7291440
1 April 2021
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7135232
28 January 2021
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7132501
15 January 2021
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7125178
21 August 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7039128
2 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6919202
14 January 2020
Deadweight Survey · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6891073
3 November 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6849518
11 February 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6623983
14 January 2019
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6613880
12 October 2017
MTSA Verification · Administrative Inspection · Plan Review (Other than "T") · Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6286437
22 February 2017
COI Inspection · Deficiency Check · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6092803
15 January 2017
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6298146
12 October 2016
Examination of Repairs · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6026604
27 April 2016
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5877843
28 March 2016
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5841974
7 March 2016
Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5840629
10 January 2016
Administrative Inspection · Hull Examination · Special · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5791543
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2025
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. There was excessive use of extension cords in the wheelhouse. Deficiency rectified.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to Minimize accidental personnel contact with energized parts. Electrical box directly beneath the stage was missing its cover and several wires were exposed. Deficiency rectified.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 24 March 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Escape door from generator room was not marked. Deficiency rectified.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 March 2025
Resolved
A vessel may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The flammables locker in the port side of the engine room was not securely mounted. Deficiency rectified.
Action required: 10 - Deficiency Rectified
Resolved 24 March 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 March 2023
Resolved
Illuminated signs with the word “EXIT” in red letters throughout a passenger vessel so the direction of escape to the open deck is obvious from any portion of the vessel usually accessible to the passengers or crew, except machinery spaces, and except stores and similar spaces where the crew are not normally employed. Inspection found 01 E-light (L4-17) was dim.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2023
Resolved
A door in a stairtower, stairway, and main vertical zone bulkhead must meet the following additional requirements - A door must be of the self-closing type capable of closing against a 3.5 list of the vessel. Inspection found fire doors (stbd 01 deck galley double doors) and
port bow 02 deck class a fire door not properly closing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 March 2023
Resolved
At least one ring buoy must be fitted with a floating water light. Inspection found ring buoy light at the pilothouse had dead batteries.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 March 2023
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine inspector.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 March 2022
Resolved
All escape hatches used as means of escape must be marked “Emergency Exit, Keep Clear.” Galley escape hatch is not labeled. Prove to the attending inspector that the galley hatch is labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 1 April 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 March 2022
Resolved
Damper on 03 Deck - Photo Lab did not function. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 March 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022
Resolved
Galley water heater pressure relief pipe relieves to brain and to another pipe which vents vertically into space. Prove to the attending inspector that the vertical pipe does not pose a risk to personnel in the vent of relief.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 1 April 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 April 2021
Resolved
Self-closing door located PORT side lower galley at bottom of stairway would not latch closed. Prove to the attending Coat Guard marine inspection that door will release from the hold back mechanism and latch close.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 19 May 2021
Resolution: The deficiency was cleared to the satisfaction of an USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 April 2021
Resolved
Self-closing door located in lower galley that enters elevator is rotting out at the bottom of door. Replace door IAW Coast Guard approved fire plans. Prove to the attending Coat Guard marine inspection that the new door meets all construction standards in the regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 29 October 2021
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 April 2021
Resolved
Prove proper operation of the emergency exit signs and lighting.
Action required: 10 - Deficiency Rectified
Due 1 April 2021
Resolved 1 April 2021
Resolution: The defieciency was cleared to the satisfaction of a USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 April 2021
Resolved
Lazzarette overhead cable transit was missing caulking and did not meet Class A structural fire protection requirements. Prove to the MI the cable thru has been caulked meeting Class A boundery requirements.
Action required: 10 - Deficiency Rectified
Due 1 April 2021
Resolved 1 April 2021
Resolution: The deficiency was cleared to the satisfaction of a USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 14 March 2019
Resolved
Conduct dead-weight survey to verify light ship characteristics.
Action required: 705 - Other - as specified
Due 29 February 2020
Resolved 14 January 2020
Resolution: The deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 March 2019
Resolved
Identify, label and prove proper operation of all ventilation fire damper closures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2019
Resolved 15 April 2019
Resolution: Received testing report and list of repairs from [name withheld].
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 March 2019
Resolved
Ensure automatic sprinkler system is installed as per approved plans.
Action required: 705 - Other - as specified
Due 21 July 2022
Resolved 29 August 2022
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2019
Resolved
The pressure vessel servicing the ships horn was missing a pressure relief valve. Provide adequete reliving device for pressure vessel meeting the ASME UV standard.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 11 March 2019
Resolved 12 March 2019
Resolution: Deficiency was corrected to the satisfaction of the attending USCG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 February 2019
Resolved
02 emergency exit lights were inoperable under emergency power. Prove emergency lights are in operating condition under emergency power.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 March 2019
Resolved 11 March 2019
Resolution: Deficiency was cleared to the satisfaction of the attending USCG Marine Inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 19 March 2018
Resolved
PFD storage locker on 4th deck, port side was missing placarding identifying size and quantity of PFDs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 21 March 2018
Resolution: The placarding for the storage locker identifying size and quantity was attached onto the storage locker.
Electrical › Electric Supply System (service) › Cable
Issued 19 March 2018
Resolved
Multiple extensions cords/daisy chained were found on both port and starboard sides of the theatre stage. These cords provided power for permanent lighting systems for the stage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 21 March 2018
Resolution: Verifed that permanent power outlets were installed in the stage area, replacing the extension cords for the lighting system on stage.
Accommodation/Occupational Safety › Ventilation › General
Issued 19 March 2018
Resolved
An old HVAC ventilation duct dampner for atrium was found to be inoperable/unsecure. This dampner needs to be secured and de-energized in the closed position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2018
Resolved 21 March 2018
Resolution: Verifed dampner was secured in the closed positions and the circuit was capped within closure.
Fire Fighting › Ventilation Systems › Smoke Extraction System
Issued 6 March 2017
Resolved
Demonstrate proper operation of the smoke extraction system for the atrium.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 8 March 2017
Resolution: Witnessed proper operation of the smoke extraction system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 March 2017
Resolved
Remove all extension cords that are being used as permanent wiring on the stage area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 8 March 2017
Resolution: All extension cords used as permanent wiring were removed.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 6 March 2017
Resolved
Prove proper operation of the alarm panel for the steering system in the pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 6 March 2017
Resolution: Burnt bulbs replaced and all alarms tested.