Records from 2016 to 2026. Most recent: inspection, 16 June 2026.
Inspection history · 16
16 June 2026
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8406690
8 April 2026
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8344516
28 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8302701
7 January 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8057046
14 March 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7877121
17 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7854069
24 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7647609
19 April 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7433703
25 January 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7383145
6 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7167596
7 February 2019
Drydock Exam · Administrative Inspection · Examination of Repairs · COI Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6624649
21 May 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6430228
2 July 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6371374
22 May 2017
Damage Survey · Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6152175
21 September 2016
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6004836
18 May 2016
Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5878918
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 April 2026
No resolution recorded
Vessel failed to complete an Annual Inspection within the 3 months before or after its anniversary date. Vessel is hauled out for hull repairs from a scheduled drydock and must complete an Annual Inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 January 2023
Resolved
There is moderate water leakage from the port and starboard shaft packing. Tighten or replace packing so there is at max one drip per second.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 January 2023
Resolved 24 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 April 2021
Resolved
Vessel's starboard throttle handle teeth are stripped preventing engine control forward and reverse. Vessel has 02 engines, but no auxiliary means of steering. Repair throttle unit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 April 2021
Resolved
Vessel's Certificate of Documentation is expired. Provide proof of COD renewal prior to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 April 2021
Resolved
Vessel has only 20 adult life jackets. Provide a total of 21 adult life jackets prior to carrying more than 20 total people on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2020
Resolved
19 Adult life jackets need new SOLAS Retro reflective tape. 31 sq inches on each side. no passengers
Action required: 705 - Other - as specified
Resolved 28 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 January 2020
Resolved
All woodwork must be protected from heat sources. Line engine spaces with noncombustible panels or material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 January 2020
Resolved
All navigation lights must be fully operational.
Action required: 705 - Other - as specified
Resolved 28 February 2020
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 January 2020
Resolved
Engine spaces must be vapor tight. Reinstall battens and secure any other openings with a fire retardant material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2020
Resolved
Install marine grade metal fuel filters with bowls.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2020
Resolved
Install bilge shut off valves at the hull penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2020
Resolved
Bond the fuel fill line to the tank top.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 January 2020
Resolved
Post all pages of the stability letter, original and amendment at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 January 2020
Resolved
Fuel tank shutoff valves shall be located at the tank connection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 July 2017
Resolved
Conduct survey of vessels port shaft and propeller to satisfaction of the attending marine inspector. Conduct satisfactory underway test of vessels propulsion system in the presence of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2017
Resolution: Successful underway trail completed, no vibrations in propulsion system.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2017
Resolved
Label visual automatic bilge operation indicator for each pump.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 13 July 2017
Resolution: Bilge indicators labeled.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 September 2016
Resolved
Provide retro-reflective tape, four locations, both sides, for ring life buoy.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 1 November 2016
Fire Fighting › Fire Pumps › Arrangement
Issued 21 September 2016
Resolved
Provide plans for approval to the marine inspector ([name withheld]) to install a power driven fire pump and associated components per 46 CFR 181.300 (New T as this will be a new installation).
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 1 November 2016
Engineering › Fuel Oil Service System › Hose
Issued 21 September 2016
Resolved
All non-metallic flexible hose used for the diesel fuel system must be suitable for its intended use and must meet SAE J1942 standards. Non-metallic flexible hose end fittings must meet SAE J1475 standards. Install non-metallic flexible hose and end fittings in accordance with 46 CFR 182.700 (New T as this will be a new installation).
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 13 March 2017
Resolution: SAE J-1475 fittings installed.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 21 September 2016
Resolved
Provide operator with Marine Radio Operators Permit (MISLE drop down box for MROP not avalable.
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 1 November 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 September 2016
Resolved
Provide written plan to the OCMI for approval addressing using the forward windows as a second means of escape from the passenger accommodation space Per 46 CFR 177.500 (New T).
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 1 November 2016
Fire Fighting › Ventilation Systems › Ducts
Issued 21 September 2016
Resolved
Provide proposal to install adequate closure devices for machinery space vents per 46 CFR 181.20-35 (Old T), 46 FR 182.465(h) (New T).
Action required: 705 - Other - as specified
Due 21 October 2016
Resolved 1 November 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 May 2016
Resolved
Re-fasten bench seat tops in the accommodation space.
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 May 2016
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 18 May 2016
Resolved
Blank off port side ac unit thru-hull no longer in use.
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 May 2016
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 May 2016
Resolved
Renew starboard MDE raw water valve.
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 May 2016
Resolved
Renew wet exhaust hose clamps inboard of transom.
Due 18 June 2016
Resolved 18 May 2016
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 18 May 2016
Resolved
Renew port cutlass bearing.
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 18 May 2016
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 May 2016
Resolved
Submit repair proposal to make permanent repairs to starboard chine log at frame seven.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 20 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 18 May 2016
Resolved
Submit repair proposal to make permanent repairs to port side sawn frame number six.
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 20 May 2016