MAURY USCG vessel records Sign in
← All vessels

TEASER

TEASER is a 2001 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2002, most recently in July 2026, along with 35 deficiencies.

Records from 2002 to 2026. Most recent: inspection, 31 July 2026.

Built
2001
Last inspected
31 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA9151
Flag
UNITED STATES
366861970, 369158000 (licence lapsed)
Maury page id
psix-39997

Inspections, by type

Years with a record 20 calendar years (2002–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVANS BOAT REPAIR INC · CRISFIELD, MD, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLA PARGUERA, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Net Ton
32 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WOEQMMSI 369158000 · expired · compulsorily equipped · granted 15 May 2014, cancelled 20 July 2024
WDA9151MMSI 366861970 · expired · voluntarily equipped · granted 17 July 2002, cancelled 22 September 2012
WOEQMMSI 369158000 · cancelled · compulsorily equipped · granted 20 June 2002, cancelled 25 July 2002
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

31 July 2026 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8451540
1 August 2025 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8192628
21 October 2024 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8022479
7 October 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8015928
11 June 2024 Deficiency Check · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7932673
21 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7774057
2 August 2023 Annual Inspection · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7762255
4 May 2022 Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7444648
2 May 2022 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7475916
9 September 2021 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7308436
1 September 2021 Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7301742
12 November 2020 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7093937
10 June 2020 Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6973807
12 September 2019 Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6811329
23 October 2018 Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6567981
3 August 2018 Annual Inspection · Examination of Repairs
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6496806
2 May 2017 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6134147
13 September 2016 Deficiency Check · Drydock Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6000341
3 August 2016 Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5968500
5 August 2014 Drydock Extension
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4944389
4 August 2014 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4943517
22 May 2014 DAPI Audit · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4864950
23 July 2012 Hull Examination · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4390200
3 May 2012 COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4300912
13 April 2009 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3456406
30 July 2008 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3284941
21 April 2008 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3189656
26 October 2007 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3087638
28 February 2007 COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2879192
9 August 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2741157
12 October 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2535712
21 September 2004 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2200197
25 February 2002 Initial Certification · Plan Review "T" Boat · Simplified Stability Test · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1652318

Deficiency record · 35

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 7 October 2024 Resolved
A vessel must comply with the applicable requirements for any radio, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Renew all radio certs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 21 October 2024
Resolution: The vessel owner also sent proof of the vessel acquiring its radio certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2024 Resolved
Installation of nozzles, flanges or other fittings for pipe connections to the tanks must be acceptable to the cognizant [name withheld] fuel tank level sensing unit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2024
Resolved 21 October 2024
Resolution: Attending MI received photo evidence showing the removal of the fuel tank sending units and their replacements with a fuel neck with cap.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 June 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The vessel TEASER was due for drydock 31MAY2024 and shall not operate commercially until credit drydock is granted by OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2024
Resolved 18 June 2024
Resolution: Commenced dry dock
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 August 2023 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Vessel's machinery space bulkheads, fore and aft, had multiple penetrations that were not watertight. Bulkheads must be made watertight to the satisfaction of an attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 21 August 2023
Resolution: Attending MI witnessed the sealing of all openings on the vessels water tight bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 2 May 2022 Resolved
Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. Repair tares and replace reflective tape in accordance with manufacturer’s instructions. 46CFR185.720
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 August 2023
Resolution: Life float was serviced and repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Label fuel shut off valves.46CFR185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2021
Resolution: Attending MI received evidence that the deficiency was corrected.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2021 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Replace 02 brackets for 10:B:C extinguishers. 46CFR181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2021
Resolution: Attending MI received evidence that the deficiency was corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2021 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Tighten up middle handrail for swim platform.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2021
Resolution: Attending MI received evidence that the deficiency was corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2021 Resolved
Except for engine exhausts, each inlet or discharge pipe that penetrates the hull below a line drawn parallel to and at least 150 millimeters (6 inches) above the deepest load waterline must have means to prevent water from entering the vessel. Cap old generator water outlet at the stern whit suitable metal valve or cap
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 September 2021
Resolution: Attending MI received evidence that the deficiency was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2019 Resolved
Install protective guards around belts for both main propulsion engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2019
Resolved 9 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 September 2019 Resolved
Various overhead light fixtures inoperative (forward cabin and aft deck).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 October 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 September 2019 Resolved
Ensure abanndon ship drills and man overboard drills are documented in accordance with 46 CFR 185.520
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 September 2019 Resolved
Ring life buoy was missing Type I retro reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 September 2019 Resolved
Provide and make available life float for inspection. New netting material was ordered and will be installed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 October 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2017 Resolved
Obtain valid CG approved first aid kit
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 4 May 2017
Resolution: Obtained valid CG approved first aid kit
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 2 May 2017 Resolved
Replace both inboard starboard MDE engine bed mounts
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 4 May 2017
Resolution: Replaced both inboard starboard MDE engine bed mounts
Communications › Audible Communications › Horn/Whistle
Issued 2 May 2017 Resolved
Prove proper operation of ships sound signaling device
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 4 May 2017
Resolution: Proved proper operation of ships sound signaling device
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 May 2017 Resolved
Obtain valid DOT approved alcohol screening device
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 4 May 2017
Resolution: Obtained valid DOT approved alcohol screening device
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 2 May 2017 Resolved
Obtain proof of 2016 MIS report submission
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 3 May 2017
Resolution: Provided proof of 2016 MIS report submission
Communications › Radio Communications › VHF Radiotelephone
Issued 3 August 2016 Resolved
Obtain and satisfactorily install a VHF Radio with DSC.
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 9 August 2016
Resolution: Obtained and satisfactorily installed a VHF Radio with DSC.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 May 2014 Resolved
The vessel was missing its Alcohol Test kits.
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 2 July 2014
Resolution: RIO Ponce received via Email proof of valid Alcohol test kits.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 May 2014 Resolved
The vessels Safety Radio Certificate was expired.
Action required: 705 - Other - as specified
Due 1 August 2014
Resolved 4 August 2014
Resolution: RIO Ponce received via Email a photo of the new Radio Safety Certificate.
Communications › Radio Communications › EPIRB
Issued 21 April 2008 Resolved
PRIOR TO OPERATION: Provide o/b properly operating category 1 EPIRB (406 mhz) with new battery and non-expired HRU.
Action required: 705 - Other - as specified
Resolved 25 May 2008
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 21 April 2008 Resolved
Provide valid FCC marine operator's permit (not GMDSS) for person in charge of vessel.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 13 April 2009
Resolution: FCC on board
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 28 February 2007 Resolved
Provide on board required alcohol testing kits as required by 46 CFR 4.06-16
Action required: 705 - Other - as specified
Due 1 April 2007
Resolved 2 March 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 February 2007 Resolved
Nonmetallic fuel oil hoses penetrate watertight bkhd between eng. room and aft compartment. Modify system as to ensure that fuel lines do not penetrate watertight bkhd (may use bkhd-installed coupling or connection on either side, etc.)
Action required: 705 - Other - as specified
Due 8 May 2007
Resolved 8 July 2007
Resolution: metal flange couplers installed at bkhd.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 August 2006 Resolved
Place wire nuts on 02 speaker wires in main console.
Action required: 705 - Other - as specified
Resolved 1 September 2006
Resolution: Recieved photo of correctly spliced wiring.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 August 2006 Resolved
Make forward bulkhead and through-deck fittings in machinery compartment watertight.
Action required: 705 - Other - as specified
Resolved 1 September 2006
Resolution: Received photographs of repairs made to bulkhead.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 9 August 2006 Resolved
Replace port side water cutlass bearing.
Action required: 705 - Other - as specified
Resolved 1 September 2006
Resolution: Received receipt from shipyard for replacement of both bearings.
Lifesaving › Inflatable Liferafts
Issued 26 July 2002 Resolved
Purchase and properly install an Inflatable Buoyant Apparatus. Must be approved under 160.010 (series) for at least 32 total persons prior to carrying passengers. To be completed to the satisfaction of the cognizant OCMI and attending marine inspector.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2002
Resolution: Owner/Operator decided to seal all bulkheads (bulkhead placement meets type II subdivision) to meet type II subdivision. With this situation, lifefloat/s arrangement will meet the lifesaving regulations.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 25 February 2002 Resolved
Register 406Mhz EPIRP with NOAA
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 7 September 2004
Resolution: Vessel owner re-newed EPIRB Registration. New expiration date is 09/07/2006
Documentation › Certificates/Documents
Issued 25 February 2002 Resolved
Get a coastwise endorsement on the COD.
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 9 December 2002
Documentation › Markings/Placards
Issued 25 February 2002 Resolved
Permanently affix vessel name and hailing port to transom.
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 29 October 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 February 2002 Resolved
Install machinery guard on starboard propulsion engine.
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 29 October 2002
Engineering › Steering Gear System
Issued 25 February 2002 Resolved
Stiffen steering hydraulic ram bracket. LEGACY COMPONENT DESC: Ram
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 August 2002
Resolved 29 October 2002
Resolution: Solid plate installed instead of 1-inch plywood - which flexed excessively.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.