The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for ANTWERP, retrieved 18 September 2026. mauryrecords.com/v/psix-399978.html
Documentation record
Tonnage as PSIX records it8032 - Dead Weight, Ton 7307 - Regulatory (Subpart C or D), Gross Ton 4812 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
21 January 2003Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1732798
19 December 2002Security Inspection
Physical examination · Aids to Navigation Team Long Island Sound · USCG Northeast District (CGD-NE) · Activity 1766958
30 April 2002Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1610855
23 July 2001Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 292043
3 August 2000Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 280582
LIFERAFTS NOT ONBOARD. BEING SERVICED BY LOCAL COMPANY. SOLAS 74/78 CHIII REG 19.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: RECIEVED FAX RECIEPT FROM VANE BROTHERS STATING SERVICE WAS COMPLETED AND RETURNED TO VESSEL. LIFERAFTS ARE SEA WORTHY.
Personnel › Certificates/Documents/Licenses
Issued 21 January 2003Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Mandatory Ship Reporting Systems
Issued 21 January 2003Resolved
VESSEL FAILED TO FAX BALLAST WATER REPORT. A REQUIREMENT OF 33 CFR 151 SUBPART D. TO BE CORRECTED PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Ballast Water Report
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2003
Resolution: VESSEL FAXED BALLAST WATER REPORT.
Fire Fighting › Emergency Fire Pumps
Issued 30 April 2002Resolved
GASKET, FOR EMERGENCY FIRE PUMP DISCHARGE LINE LOCATED AFT IN MAIN SPACE, IS LEAKING NEAR CUTOFF VALVE. A VIOLATION OF SOLAS 74/78 II-2/21. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 May 2002
Resolved 21 January 2003
Resolution: REPLACED GASKET, OPERATIONAL TEST CONCLUDED THAT THE LINE WAS LEAK FREE.
Engineering › Steering Gear System
Issued 30 April 2002Resolved
ELECTRICAL WIRES FOR FLOAT SENSOR IN STEARING GEAR PUMP NO.1 HYDRAULIC TANK NOT PROPERLY INSTALLED IN STUFFING TUBE. A VIOATION OF SOLAS 74/78 II-1/26 AND SOLAS 74/78 II-1/41.3. LEGACY COMPONENT DESC: Pump
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 6 May 2002
Resolved 21 January 2003
Resolution: REPLACED FLOAT SENSOR AND WIRES.
Fire Fighting
Issued 3 August 2000Resolved
COMPLETE INTERNATIONAL SHORE CONNECTION WAS MISSING FROM ITS ASSIGNED LOCATION AND COULD NOT BE FOUND ONBOARD DURING ANNUAL FREIGHT EXAM, A VIOLATION OF SOLAS 74/78 CHAPTER II-2 REG 19 AND 19/4. CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.