BIENVILLE (ACOE)

Built
Not recorded
Last inspected
13 August 2025
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 13 August 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 6 calendar years (1993–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

399998
Flag
UNITED STATES
Maury page id
psix-399998

Documentation record

Tonnage as PSIX records it151 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 8 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CEMVN CRANE BARGE 9701 Freight Barge · MISLE 1031598 · 17 July 2009 · activity 3561095228 Freight Barge · MISLE 273293 · 19 September 1993 · activity 181636DH 9305 Freight Barge · MISLE 390505 · 19 September 1993 · activity 181636VMC 562 Freight Barge · MISLE 399996 · 19 September 1993 · activity 181636IAI 6 Freight Barge · MISLE 399997 · 19 September 1993 · activity 181636

Inspection history · 8

13 August 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8209170
31 July 2024 COI Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7971158
4 January 2024 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7845068
22 November 2022 COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7598375
15 July 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7507419
27 July 2021 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7271536
17 July 2009 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3561095
19 September 1993 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 181636

Deficiency record · 17

02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 22 November 2022 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Inspector discovered 03 watertight doors and 01 watertight hatch throughout the ship that had worn or incorrect gaskets and zerks that had been painted over. Additionally, several openings for wiring leading out the engine room were no longer in use. 46 CFR 144.320(b)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 December 2022
Resolved 7 December 2022
Resolution: Crew replaced gasketing and zerks. Conducted chalk test, satisfactory. Crew also plugged all openings leading to the machinery space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2022 Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b) of this part. Inspector found that the storage cabinet for combustible materials was not vaportight and did not have a nearby extinguisher. 46 CFR 142.225(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 14 December 2022
Resolution: Sent picture of all fire hazards removed from cabinets. No longer need extinguisher in vicinity of the cabinet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 November 2022 Resolved
Electrical equipment must be marked with its respective current and voltage ratings. The distribution panel did not have voltage listed. 46 CFR 143.400(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 14 December 2022
Resolution: Sent picture with labeled voltage on distribution panel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 November 2022 Resolved
Where practicable and except as provided in § 144.515, each space where crew may be quartered or normally employed must have at least two means of escape. Arrangements on an existing vessel may be retained if it is impracticable or unreasonable to provide two means of escape. Inspector discovered that the escape hatch for the auxiliary machinery room was inoperable. 46 CFR 144.500
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 7 December 2022
Resolution: Crew loosened and oiled the escape hatch. Inspector witnessed opening, escape, and closing of the hatch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 November 2022 Resolved
The following systems must be equipped with gauges at the machinery location: auxiliary generator engine lubricating oil pressure, RPM, and cooling water temperature. Vessel did not have RPM gauging for either auxiliary generator engines locally. 46 CFR 143.230(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 14 December 2022
Resolution: Sent picture of newly installed RPM gauges.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. When the port shaft is engaged, there is excessive leaking from the packing. 46 CFR 143.205(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 14 December 2022
Resolution: Sent videos of shaft in normal operation (forward and reverse) with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 November 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Submersible pump for shafts is rigged in a temporary fashion, i.e. not hard wired, despite being required for regular operations, posing an electrical hazard. 46 CFR 143.400(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 December 2022
Resolved 27 December 2022
Resolution: Vessel obtained and installed pull proof plugs. Submersible pump for shafts is no longer rigged in a temporary fashion.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 August 2022 Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. (f) Decks and bulkheads designed to be watertight or weathertight must be maintained in that condition. Watertight doors on vessel did not seal. Replace dogs and gaskets. MI discovered holes in the WT aft engine room bulkhead and on WT bulkhead between steering flat and engine room. Seal holes. 46CFR140.610(a) and (f)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 9 August 2022
Resolution: Sent pictures of the replaced dogs, gaskets and sealed holes.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 August 2022 Resolved
Stop any mechanical ventilation system for the engine room and effectively seal all natural openings to the space to prevent leakage of the extinguishing agent. Engine room fans on weatherdeck did not have means to seal off engine room. Add vent covers to ventilation. 46CFR142.245(a)(1)(iii)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 15 August 2022
Resolution: See photo of vent covers
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 August 2022 Resolved
Emergency lighting must be provided for all internal crew working and living area. Emergency lighting was not present in steering flat, in the wheelhouse or in staterooms. Add emergency lighting. 46CFR143.410(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 15 August 2022
Resolution: Sent pictures of the emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 August 2022 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Electrical panel in engine room was not labeled. Label accordingly. 46CFR143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2022
Resolved 15 August 2022
Resolution: Sent pictures of electrical panel labeled.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 4 August 2022 Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crewmembers. If posting is impractical, such as in an open boat, they may be kept onboard in a location readily available to the crew. Vessel did not have Station Bill available. 46CFR140.405(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 15 August 2022
Resolution: Saw emergency station bill
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2022 Resolved
EAP education program: Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have EAP contacts posted. Post contact information conspicuously.46CFR 16.401 (b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 15 August 2022
Resolution: Saw DAPI posted on mess deck
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2022 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards, including but not limited to: (14) Potable water supply.Vessel's health and safety plan did not include potable water. Add section and label sinks, showers and faucets accordingly.46CFR140.510(a)(14)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 15 August 2022
Resolution: Saw posted on the sinks
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2022 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: (8) Oil residue discharges and disposals, in accordance with § 140.655. Vessel did not have oil discharge records onboard.46CFR140.915(a)(8)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 15 August 2022
Resolution: Saw the oil discharge log
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 27 July 2021 Resolved
Each towing vessel must have a means to provide notification when an emergency condition exist or an essential system develops problems that require attention. Vessel could not demonstrate the alarm conditions for both Main engines, and Aux generators.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2021
Resolution: Vessel preformed satisfactory test of all required engine alarms.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 27 July 2021 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation. Vessel must be equipped with a illuminated magnetic compass. Vessel did not have a illuminated magnetic compass.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2021
Resolution: Vessel installed a properly functioning Magnetic Compass.

Ownership record