Records from 1994 to 2004. Most recent: inspection, 22 March 2004.
Inspection history · 18
22 March 2004
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2023509
30 April 2002
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1611244
21 April 2002
MARPOL Annex I Examination · Passenger/Freight Vessel Examination · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1607950
27 April 2000
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 277239
12 February 2000
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 274647
22 December 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 423725
18 August 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 419248
11 February 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 472631
9 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 38121
7 August 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 393839
21 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 58835
6 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 385501
21 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 382988
20 September 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 72520
12 April 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 96847
31 January 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 374753
15 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 489711
14 January 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 535593
Fire Fighting › Combustible Materials
Issued 22 April 2002
Resolved
Fuel leaking from fuel filter on emergency generator fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2002
Resolved 25 April 2002
Resolution: ABS surveyor inspected e-gen, performed operational test. cleared deficency.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 April 2002
Resolved
Guardrails missing in two locations. First on the winch platform between holds 3 and 4. Second set missing on the roof of the reefer compartment between holds 2 and 3. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 5 May 2002
Resolved 23 March 2004
Resolution: CORRECTED.
Lifesaving
Issued 27 April 2000
Resolved
Pilot lifebuoy floating light not operating. SOLAS 74 amended III/19.2.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 27 April 2000
Resolved
Air foam extinguishers, located on the #1 messdeck and aft by bulkhead 12 ,have cracked hose and are in poor condition. SOLAS 74 amended II-2/21
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
The stairwell leading to port and starboard side embarkation decks have worn holes through the metal. ICLL 66 I/15.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Electrical
Issued 27 April 2000
Resolved
Boatswain and anchor lockers have burnt out lights. SOLAS 74 amended I/11.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Accommodation/Occupational Safety
Issued 27 April 2000
Resolved
The toilets and the sink in the ship's hospital space are not operational. ILO 147.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 27 April 2000
Resolved
Fire stations #34 and #35 have broken handles on nozzles. SOLAS 74 amended II/21.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Unknown
Issued 27 April 2000
Resolved
Both starboard and port lifeboats did not have water, fire extinguishers were not secured, and SOLAS reflective tape was defective. SOLAS 74 amendedIII/19.2; 30.2.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Electrical
Issued 27 April 2000
Resolved
Two forward embarkation lights on port side lifeboat deck do not rotate freely. SOLAS 74 amended I/11.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Electrical
Issued 27 April 2000
Resolved
The forward port embarkation light does not work. SOLAS 74 amended I/11.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Unknown
Issued 27 April 2000
Resolved
The elevated walkway amidships is wasted. ICLL 66 I/15.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Unknown
Issued 27 April 2000
Resolved
The hospital space contains medication passed expiration date. ILO 147
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Navigation
Issued 12 February 2000
Resolved
33 CFR 164.33 Missing the International and Inland Rules of the Road, and the US Coast Pilot.
Condition: Unknown
Due 17 November 2000
Resolved 17 November 2000
Lifesaving
Issued 12 February 2000
Resolved
SOLAS 74/78 Amended all ships III 18-3 Abandon ship drill was not tested.It will be tested prior to departing Dutch Harbor.
Condition: Unknown
Due 1 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 12 February 2000
Resolved
SOLAS 74/78 Amended II-2 Part A Reg 5 The seal on the starter air tanks for the fixed Halon system failed, bleeding off the entire air tank. The leak was caused by a paper seal that failed.
Condition: Unknown
Due 12 February 2000
Resolved 16 February 2000
Navigation
Issued 12 February 2000
Resolved
SOLAS 74/78 Amended II-1 Reg 29-5.2 Main and Auxiliary steering gear needs operational visual and audible alarms signaling a loss of power.
Condition: Unknown
Due 12 February 2000
Resolved 16 February 2000
Lifesaving
Issued 12 February 2000
Resolved
SOLAS 74/78 Amended I Reg 11(a) The fuel pipe access tunnel was full of water and at least an inch of fuel. The access tunnel runs the length of the ship, is located under the cargo holds, and contains all the fuel linesfor the fuel tanks. It is unknown where the fuel and water are coming from.
Condition: Unknown
Due 1 March 2000
Resolved 10 March 2000
Engineering
Issued 12 February 2000
Resolved
SOLAS 74/78 Amended I Reg 11(a) The air filter for the main engine was excessively oily and needs to be cleaned or replaced. In it's current condition, the filter presents a significant fire hazard.
Condition: Unknown
Due 1 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 12 February 2000
Resolved
SOLAS 60 II Reg 56(f) All fire stations were missing spanner wrenches.
Condition: Unknown
Due 1 March 2000
Resolved 10 March 2000
Electrical
Issued 12 February 2000
Resolved
SOLAS 74/78 I Reg 11(a) The light fixtures in the engine room were missing all missing covers. The bulbs and electrical sockets were exposed without any protective covering.
Condition: Unknown
Due 15 April 2000
Resolved 12 February 2002
Resolution: Discrepancy resolved by MSO Anchorage 12 Feb 02
Lifesaving
Issued 12 February 2000
Resolved
SOLAS 74 Unamended I Reg 11 The engines and generators lacked a proper fuel/lube oil drain system. On numerous pieces of equipment, the leaking oil was dripping onto the engine itself, or diverted onto other pieces of equipment.
Condition: Unknown
Due 1 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 12 February 2000
Resolved
SOLAS 74/78 Amended all ships II-2 Reg 17-1.3 Firefighting equipment did_x001C_not adequately protect crew from flames and hot gas.
Condition: Unknown
Due 1 March 2000
Resolved 10 March 2000
Documentation
Issued 22 December 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 December 1998
Resolved 31 December 1998
Navigation
Issued 22 December 1998
Resolved
PLACE PROPER WARNING STATEMENT ON MANEUVERING FACT SHEET, AS DESCRIBED IN 33 CFR 164.35q PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 December 1998
Resolved 31 December 1998
Fire Fighting
Issued 22 December 1998
Resolved
SHOW PROPER LOCATION OF THE INTERNATIONAL SHORE CONNECTION ON THE FIRE CONTROL PLAN PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 December 1998
Resolved 31 December 1998
Lifesaving
Issued 18 August 1998
Resolved
PROVE PROPER OPERATION OF PORT LIFEBOAT ENGINE, ENGINE IS INOPERATIVE._x001C_ SOLAS 60 III/8(b)(c)
Condition: Unknown
Due 24 August 1998
Resolved 1 September 1998
Fire Fighting
Issued 6 December 1995
Resolved
PRIOR TO DEPARTING PORT OF TAMPA, PROVE PROFESSIONAL SERVICING HAS BEEN CONDUCTED ON FIXED FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Lifesaving
Issued 31 January 1995
Resolved
SOLAS 74 AMENDED CHAPTER III REG 30_x001C_ RETRO REFLECTIVE TAPE ON ALL LIFE RINGS WERE OLD AND MISSING.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Lifesaving
Issued 31 January 1995
Resolved
SOLAS 74 _x001C_ LIFEBOAT PROVISIONS WERE NOT IN THE LIFEBOATS.
Condition: Unknown
Due 1 February 1995
Resolved 3 February 1995
Lifesaving
Issued 31 January 1995
Resolved
SOLAS 74 AMENDED CHAPTER III REG 30_x001C_ RETRO REFLECTIVE TAPE ON THE LIFE BOATS WERE OLD AND MISSING.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995
Lifesaving
Issued 31 January 1995
Resolved
SOLAS 74 AMENDED CHAPTER III REG 38._x001C_ MISSING WEAK LINKS ON THE ALL LIFE RAFTS.
Condition: Unknown
Due 25 September 1995
Resolved 25 September 1995