Records from 1994 to 2023. Most recent: inspection, 8 February 2023.
Documentation record
Registered dimensions (L × B × D)46.5 ft × 14.3 ft × 6.2 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1994
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
27 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
8 February 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7627106
20 January 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7127739
28 February 2020
Drydock Exam · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6902325
29 March 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6644649
5 March 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6366363
16 March 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6095518
2 March 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5822725
15 May 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4857226
22 June 2012
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4352456
18 May 2005
Hull Examination · COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2361079
20 September 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412361
31 August 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435093
14 June 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399145
18 May 1999
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468509
18 August 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434771
4 August 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411495
14 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1091189
9 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412948
28 April 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416130
28 April 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1175512
14 March 1994
Initial Construction-Excluding Oversight · Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426926
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 May 2020
No resolution recorded
Contact Sector New Orleans for a full COI inspection prior to the carraige of passengers.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 April 2020
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisifactory condition, fir for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Vessel must conduct a COI Inspection in the water by 14JUL2020 (90 days).
46CFR176.404(a) 705 c
Action required: 705 - Other - as specified
Due 14 July 2020
Resolved 21 May 2020
Resolution: COI conducted.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 16 March 2017
Resolved
Replace flame screen on fuel tank vent with approved type. 46 CFR 182.20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2017
Resolved 11 May 2017
Resolution: Received documentation from vessel representative that the flame screen for the fuel vent had been replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 March 2016
Resolved
Vessel on blocks ashore. Unable to test/verify any operational gear or verify drills. Prior to operation, conduct an annual inspection with operational tests/drills.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2017
Resolved 21 May 2020
Resolution: This requirement has been extended until the expiration of the COI on 13May2020 and prior to getting underway.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 March 2016
Resolved
High level alarm in steering gear room and engine room not wired correctly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 16 July 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 March 2016
Resolved
Battery cover for generator missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 16 July 2017
Resolution: Cover installed.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 2 March 2016
Resolved
Missing waste management plan.
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 17 March 2017
Resolution: Plan provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 May 2014
Resolved
Prior to sailing complete an annual inspection
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2016
Resolution: Reissued as deficiency for this inspection. Also, it wsa a duplicate of another def issued two days earlier.
Documentation
Issued 14 March 1994
Resolved
PROVIDE ON BOARD VALID FCC RADIO SAFETY CERTIFICATE._x001C_
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994