Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7638167 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
400039
Flag
PANAMA
—
Maury page id
psix-400039

Inspections, by type

…with no type recorded10
Years with a record 13 calendar years (1994–2009)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9583 - Dead Weight, Ton
16850 - Displacement, Ton
12374 - Convention (Subpart B), Gross Ton
3967 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

14 January 2009 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3393936
18 October 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3347115
17 July 2007 Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2995571
22 September 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2784728
19 July 2006 ISPS II Exam · Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2717404
21 April 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2630182
26 January 2006 MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2569881
10 January 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2564416
21 April 2005 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2339933
10 February 2005 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2290133
15 November 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2237669
6 February 2004 Special Interest Vessel
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2002083
26 January 2004 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1992822
20 March 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1756382
20 June 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1633725
9 February 2002 Annual Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1485403
26 November 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 295815
1 February 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286435
4 November 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 434298
25 March 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 426773
19 May 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 402525
13 December 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 398418
9 September 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 395137
28 December 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 373768
28 December 1994 Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850867
18 January 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 482658

Deficiency record · 21

Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 October 2008 Resolved
VESSEL IS UNDERGOING DECK REPLACEMENT FOR SHOWER ABOVE CORRIDOR NEAR GALLEY,, BUT A HOLE HAS BEEN CUT BETWEENT ENGINE SPACE AND CORRIDOR. "A" CLASS CONSTRUCTION IN BULKHEAD MUST BE RESTORED TO THE SATISFACTION OF CLASS. SOLAS '60 CH. II/ REG. 40
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 January 2009
Resolution: Received class report from RMRS attesting that permanent repairs had been made and approved in restoring the "A" Class construction of the bulkhead.
Engineering › Freshwater System (piston cooling) › Piping
Issued 17 July 2007 Resolved
The Main Engine has piston cooling water leaks on cylinders no.2 and no. 4 at the telescoping pipe. Repair to the satisfaction of the attending classification society prior to movement.
Action required: 705 - Other - as specified
Due 17 July 2007
Resolved 25 July 2007
Resolution: Received class report from Russian Maritime Register satisfying requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Charge Air Cooling
Issued 17 July 2007 Resolved
The drain line from cylinder no. 4 is broken and an excessive amount of oil is found around the area. Additionally, the no. 6 drain line is broken with a flexible hose attached to both ends of the pipe. Repair to the satisfaction of the attending classification society and provide attestation to the cleanliness of the scavenger air box prior to movement.
Action required: 705 - Other - as specified
Due 17 July 2007
Resolved 25 July 2007
Resolution: Received class report from Russian Maritime Register satisfying requirement.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 January 2006 Resolved
Broken handrails adjacent to generator in the engine room, starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2006
Resolved 21 April 2006
Resolution: Received class report clearing deficiency.
Engineering › Feedwater/Condensate Water System › Piping
Issued 26 January 2006 Resolved
Temporary patch on piping in boiler room above condenser.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 February 2006
Resolved 21 April 2006
Resolution: Received class report clearing deficiency.
Construction/Loadline › Hull › Bottom Plating
Issued 10 February 2005 Resolved
Class to attest to structural integrity of hull plating ivo deep indentations in the port bow as per SOLAS II-1/3-1
Action required: 705 - Other - as specified
Resolved 21 April 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO STUCTURAL INTEGRITY AND HULL PLATING IN PORT BOW.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 November 2004 Resolved
Missing electric matting in engine room on stbd side bottom level and in control room. Also in CO2 room.
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2005
Resolution: Electric matting provided to the satisfaction of the Coast Guard Marine Inspector.
Construction/Loadline › Markings › Load Line Mark
Issued 15 November 2004 Resolved
Paint loadline
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2005
Resolution: Loadline sufficient to the satisfaction of the Coast Guard Marine Inspector.
Construction/Loadline › Markings
Issued 20 March 2003 Resolved
PLIMSOLL MARK WAS NOT IN CONTRASTING COLOR.
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 26 January 2004
Resolution: Received a class report from RS. The Loadline marks were painted in a contrasting color to the hull and approved by class.
Construction/Loadline › Structures
Issued 20 March 2003 Resolved
WASTED LADDER RUNG THIRD STIP UP LEADING TO ANCHOR WINDLASS
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 26 January 2004
Resolution: Received a class report from RS. Ladders on Port & STBD were replaced with new ones.
Construction/Loadline › Hull
Issued 20 March 2003 Resolved
VARIOUS WASTAGE AND FRACTURES ON GUNNELS/RAILS, PORT AND STARBOARD
Action required: 705 - Other - as specified
Due 20 May 2003
Resolved 26 January 2004
Resolution: Received class report from RS. Wasted areas were repaired to the satisfaction of class.
Engineering › Diesel Engine (auxiliary)
Issued 9 February 2002 Resolved
NO. 1 GENERATOR MAIN FUEL PUMP IS LEAKING EXCESSIVELY. DO NOT OPERATE UNTIL REPAIRS ARE APPROVED BY CLASS. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 20 June 2002
Resolution: Rcvd Class report spot check system
Engineering › Diesel Engine (auxiliary)
Issued 9 February 2002 Resolved
NO. 1 GENERATOR #6 CYLINDER HAS EXCESSIVE COOLING WATER LEAK. LEGACY COMPONENT DESC: Cylinder Head
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 20 June 2002
Resolution: Rcvd Class report Spot check system
Engineering › Diesel Engine (auxiliary)
Issued 9 February 2002 Resolved
NO. 1 GENERATOR HAS EXCESSIVE OIL LEAKING FROM VALVE COVERS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 20 June 2002
Resolution: Rcvd Class report Spot check system
Engineering › Steering Gear System
Issued 9 February 2002 Resolved
STEERING GEAR IS LEAKING EXCESSIVELY FROM FORWARD STARBOARD AND PORT AFT RAM SEALS. LEGACY COMPONENT DESC: Ram Seal
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 February 2002
Resolved 20 June 2002
Resolution: Rcvd Class report spot check system
Engineering
Issued 26 November 2001 Resolved
Provide as original, insulation covers for high pressure fuel lines on mainengine. USCG to verify correction. SOLAS 60/II
Condition: Unknown
Due 26 December 2001
Resolved 9 February 2002
Resolution: Observed new fuel lines and accepted receipt from manufacturer.
Accommodation/Occupational Safety
Issued 9 September 1996 Resolved
RENEW ALL MISSING/DETERIORATED GUARD RAILS LOCATED ON THE STARBOARD SIDE OFTHE 01 DECK._x001C_ SEE ICLL 66 REGULATION 25.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Fire Fighting
Issued 9 September 1996 Resolved
PROVIDE ONBOARD FOR REVIEW THE INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE._x001C_ SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Lifesaving
Issued 9 September 1996 Resolved
PROVIDE ONBOARD FOR REVIEW THE INSTRUCTIONS FOR ONBOARD MAINTENANCE OF LIFESAVING APPLIANCES._x001C_ SEE SOLAS 74 (AMENDED) III/19.3,52
Condition: Unknown
Due 13 December 1996
Resolved 13 December 1996
Engineering
Issued 9 September 1996 Resolved
RENEW AS ORIGINAL THE DETERIORATED MAIN ENGINE SEA WATER COOLING PIPE LOCATED ON THE STARBOARD SIDE, LOWER LEVEL OF THE ENGINE ROOM, OUTBOARD OF THE MAIN ENGINE AT THE SEA WATER OVERBOARD [CEMENT BOX INSTALLED PRESENTLY]SEE SOLAS 74 (AMENDED) I/11(a)
Condition: Unknown
Due 13 December 1996
Resolved 13 December 1996
Fire Fighting
Issued 9 September 1996 Resolved
INSTALL AN APPROPRIATE FIRE-EXTINGUISHING SYSTEM IN THE PAINT LOCKER, LOCATED ON THE STARBOARD SIDE OF THE FORECASTLE._x001C_ SEE SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996

Ownership record