TROPICAL WINDS

TROPICAL WINDS is a 1994 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in March 2026, along with 24 deficiencies and 2 casualty investigations between 2005 and 2009.

Records from 2005 to 2026. Most recent: inspection, 23 March 2026.

Built
1994
Last inspected
23 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCG4044
400148
Flag
UNITED STATES
Maury page id
psix-400148

Documentation record

Registered dimensions (L × B × D)65.0 ft × 19.0 ft × 8.0 ft
Registered tonnagegross 66 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAVIGATOR BOATS · ELMORE, AL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Simplified, Net Ton
66 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

23 March 2026 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8330410
9 March 2026 Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8323355
2 February 2026 Vessel Attendance · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304806
24 September 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8241093
3 September 2025 Special Consideration · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226507
11 March 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8095262
20 March 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7882449
5 February 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7859595
23 October 2023 In-Service Inspection · Special · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7812992
8 March 2023 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7647432
8 March 2023 Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7648336
19 August 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7537938
10 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7397912
27 December 2021 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7374842
3 December 2021 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7361807
29 April 2021 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7185839
11 May 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6951392
11 February 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6907301
15 October 2019 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6839024
30 April 2019 Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6674137
23 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570697
3 May 2018 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6400037
26 March 2018 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6375962
14 April 2017 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6124319
21 February 2017 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6088380
31 May 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5892243
10 May 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5872633

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2025 Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type, a space containing propulsion machinery and a space containing an internal combustion engine of more than 50 hp. The engine room was not fitted with an alarm system. Install alarm system in the engine room such that the actuation of the alarm results in both audible and visual alarms in all areas required by 46CFR181.405(c). 46CFR181.405(c) 46CFR181.450 46CFR175.110(c)
Action required: 10 - Deficiency Rectified
Due 11 March 2025
Resolved 11 March 2025
Resolution: Installed additional interconnected smoke detector in engine space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2025 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 and must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose. The return fuel line to the cooler was missing part of the factory-assembled end fitting. Replace/repair hose. 46 CFR 182.720(e)
Action required: 10 - Deficiency Rectified
Due 11 March 2025
Resolved 11 March 2025
Resolution: Replaced hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 11 March 2025 Resolved
For the purpose of flexibility only, flexible hose installed in lengths of not more than 760 millimeters (30 inches) and subject to pressures of not more than 35 kPa (5 psig), may meet the following requirements: Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose; and USCG Type A1, A2, B1, or B2 flexible hose may be accepted. The fuel line from the fuel filter on the port generator did not have a hose clamp installed and the flexible hoses were not SAE J-1942 nor USCG Type A1, A2, B1, or B2 flexible hoses. Replace hoses and install hose clamps on hoses. 46 CFR 182.720(e)(3)(v)
Action required: 10 - Deficiency Rectified
Due 11 March 2025
Resolved 11 March 2025
Resolution: Replaced hoses and installed hose clamps.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 23 October 2023 Resolved
A night watchman system must be installed and functioning prior to carrying more than six (6) overnight passengers. Prove proper operation and understanding of the system. The vessel is restricted to carrying not more than six (6) overnight passengers until the system is tested for proper operation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 November 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2023 Resolved
An interconnected fire detector must be installed in all areas where passengers and crew have access. Prove proper operation and understanding of the system. The vessel is restricted to operating not more than twenty(20) nautical miles from shore until the system is tested for proper operation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 November 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 October 2023 Resolved
A passenger safety bill must be generated and posted in the cabin and accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2023
Resolved 7 November 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 March 2024
Resolved 20 March 2024
Resolution: System provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 March 2023 Resolved
Inspect fire protection equipment in accordance with 46 CFR 176.810. Port engine room ventilation cover was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 23 October 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2023 Resolved
Inspect steering systems in accordance with 46 CFR 176.814.Port steering ram hose was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 23 October 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2023 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Fwd bunk room bilge pump ovbd valve was unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2023
Resolved 23 October 2023
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 March 2023 Resolved
Inspect superstructure in accordance with 46 CFR 176.802. Stbd aft window was cracked.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2023
Resolved 23 October 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 December 2021 Resolved
Prove stability in accordance with 46 CFR 178. Vessel repowered resulting in a weight change. Vessel total persons is reduced to 41 total persons. Vessel to complete Stability Test by 31 Dec 22.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2022
Resolved 8 March 2023
Resolution: Completed satisfactory SST.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 December 2021 Resolved
Vessel must comply with FCC requirements in accordance with 46 CFR 184.502. VHF radio DSC function was not programmed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2022
Resolved 8 March 2023
Resolution: DSC function programmed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 October 2019 Resolved
Repair broken weld on starboard rudder mount to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2019
Resolved 25 October 2019
Resolution: Rewelded cracked weld on steering stanchion.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 15 October 2019 Resolved
Label port and starboard emergency escape exits.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 25 October 2019
Resolution: Emergency exits labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2019 Resolved
Weak link attached to life floats wasn't proper size. Replace size to match current capacity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 6 May 2019
Resolution: Replace weak link with a 21 plus, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 April 2019 Resolved
Port side light has broken mount and light is extinguished. Replace mount and light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 6 May 2019
Resolution: Repaired port side light and mounted, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 March 2018 Resolved
Provide valid Fire Servicing Report.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2018
Resolved 29 March 2018
Resolution: CO2 System and Fire Exstinguishers were serviced/report completed.
Construction/Loadline › Hull › Hull Plating
Issued 14 April 2017 Resolved
Properly repair delaminated fiberglass along portside in accordance with vessel approved layup schedule and fire retardant restin. Underway operational test is required following repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2017
Resolved 27 June 2017
Resolution: Vessel completed satisfactory repair.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 February 2017 Resolved
High water alarms audible and visual, make operational, in the Lazarette and Tankroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 28 February 2017
Engineering › Bilge Water Management System › Valve
Issued 21 February 2017 Resolved
Replace the tank compartment bilge discharge valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 28 February 2017
Construction/Loadline › Hull › Side Shell
Issued 21 February 2017 Resolved
repair the FRPtabbing located in the FWD berth.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 28 February 2017
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 February 2017 Resolved
Clean bilge or oil and trash.
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 28 February 2017
Construction/Loadline › Structures › Scuttle
Issued 21 February 2017 Resolved
replace fwd scuttle gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2017
Resolved 28 February 2017

Casualty record · 2

21 April 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2340850
23 October 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 injured · activity 3623779
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.