MAURY USCG vessel records Sign in
← All vessels

BRANSONS AMERICAN STAR

BRANSONS AMERICAN STAR is a 1994 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1994, most recently in October 2010, along with 46 deficiencies.

Records from 1994 to 2010. Most recent: inspection, 12 October 2010.

Built
1994
Last inspected
12 October 2010
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCR4663
400155
Flag
UNITED STATES
—
Maury page id
psix-400155

Inspections, by type

…with no type recorded12
Years with a record 13 calendar years (1994–2010)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.6 ft × 20.0 ft × 5.4 ft
Registered tonnagegross 51 / net 34
ITC dimensions (L × B × D)72.6 ft × 20.0 ft × 5.4 ft
ITC tonnageNot recorded
BuilderMID-CITY STEEL FABRICATING · LA CROSSE, WI, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBRANSON, MO
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it51 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCR4663MMSI not assigned · expired · voluntarily equipped · granted 9 May 1995, cancelled 9 July 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 43

12 October 2010 Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3869063
27 April 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2344163
5 April 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2327193
16 September 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2045339
18 May 2004 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2067781
1 May 2004 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2195852
18 September 2003 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1910523
22 May 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1799294
7 April 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1769553
2 May 2002 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1611964
10 April 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1597104
14 September 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 213874
23 May 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1066175
11 April 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1467748
18 April 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 212039
10 April 2000 Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1424902
29 March 2000 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1466125
28 March 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1047050
13 September 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 698555
2 September 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1118024
7 July 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1093776
17 June 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 698554
7 June 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 215014
21 April 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 698556
12 April 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 214163
12 April 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406475
28 September 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 24475
20 May 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1127390
8 April 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1402645
29 July 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 781289
17 April 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1390501
17 May 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1085034
12 April 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1470414
6 March 1996 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1081383
12 April 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1172588
3 October 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1178617
2 August 1994 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 866206
29 July 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1172270
6 July 1994 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1175531
17 June 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1328667
17 June 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1396122
27 May 1994 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458162
8 April 1994 Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1168059

Deficiency record · 46

Construction/Loadline › Markings
Issued 7 April 2003 Resolved
Properly mark vessel reference line as per vessel's stability letter. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Due 14 May 2003
Resolved 19 May 2003
Resolution: Reference lines, of a contrasting color to the hull, were affixed to the hull of the vessel in accordance with the vessel''s stability letter.
Lifesaving › Lifebuoys
Issued 7 April 2003 Resolved
Properly mark ring buoys with retro-reflective material. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper Installation
Due 14 May 2003
Resolved 29 June 2003
Operations/Management › Navigation Safety
Issued 10 April 2002 Resolved
Provide and maintain onboard updated NAVRUL publication. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 15 April 2002
Engineering › Steering Gear System
Issued 10 April 2002 Resolved
Properly repair oil leak on steering gear ram. LEGACY COMPONENT DESC: Ram Seal
Condition: Unknown
Due 10 May 2002
Resolved 8 May 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 April 2002 Resolved
Provide specifications and documentation on newly installed carpet. LEGACY COMPONENT DESC: Open Deck Space
Condition: Unknown
Due 10 May 2002
Resolved 26 April 2002
Electrical
Issued 11 April 2001 Resolved
Ensure all overhead wires are properly secured in compressor room.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 11 April 2001 Resolved
Properly adjust forepeak deck scuttle to prevent water from entering compartment.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Accommodation/Occupational Safety
Issued 11 April 2001 Resolved
Install relief valve on 12 gallon fresh water tank located in fuel tank space.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Electrical
Issued 11 April 2001 Resolved
Make repairs to generator to prevent excessive buildup of oil on windings.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Construction/Loadline
Issued 12 April 1999 Resolved
Install fire stop in overhead of wire run in number 4 void._x001C_ _x001C_
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 12 April 1999 Resolved
Verify amp draw on galley outlet box to ensure circuit is not overloaded and install receptacle box.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
Install high blige alarm in 5 aft voids.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Engineering
Issued 12 April 1999 Resolved
Repair water leak on muffler of starboard main engine.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 12 April 1999 Resolved
Properly wire soda machine.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 12 April 1999 Resolved
Remove dead end wire under console.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Documentation
Issued 12 April 1999 Resolved
Prior to getting underway with passengers, provide proper training to senior deckhand and designate in writting.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 12 April 1999 Resolved
Properly wire rudder angle indicator and prove proper operation.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Engineering
Issued 12 April 1999 Resolved
Renew fuel hoses on main engines and generator.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
Install life jacket donning instructions.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 8 April 1998 Resolved
Install lifejacket donning placard.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Lifesaving
Issued 8 April 1998 Resolved
Install 5/16 buoyant line on life ring.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Navigation
Issued 8 April 1998 Resolved
Ensure all movable parts of the steering gear are double nutted or have nylock nuts.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Lifesaving
Issued 8 April 1998 Resolved
Install a U.S.C.G. approved first aid kit.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Lifesaving
Issued 17 April 1997 Resolved
Provide realistic man overboard dummy to prove feasibility of removing MOB from water.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Engineering
Issued 17 April 1997 Resolved
Prove proper operation of oil pressure and high water temp gauges for generator on bridge.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Documentation
Issued 17 April 1997 Resolved
Prove participation in random perodic/pre-employment drug screening program.
Condition: Unknown
Due 17 April 1997
Resolved 17 April 1997
Electrical
Issued 12 April 1996 Resolved
REMOVE ALL OVERHEAD NYLON TIES FROM CABLING AND REPLACE WITH METAL TIES.
Condition: Unknown
Due 12 April 1996
Resolved 12 April 1996
Lifesaving
Issued 12 April 1996 Resolved
REPLACE MISSING LETTERING ON RING BUOY IWO MAIN DECK PORTSIDE FWD.
Condition: Unknown
Due 12 April 1996
Resolved 12 April 1996
Lifesaving
Issued 12 April 1996 Resolved
PROPERLY SECURE WATERLIGHT TO RING BUOY USING 3 TO 6 FEET OF LINE AND PROPER CLASP.
Condition: Unknown
Due 12 April 1996
Resolved 12 April 1996
Documentation
Issued 12 April 1995 Resolved
PROVIDE PROOF OF EMPLOYEE ENROLLMENT IN ANNUAL RANDOM DRUG/CHEMICAL TESTINGAS PER 46CFR 16.230.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 2 August 1994 Resolved
PROVIDE PROOF OF ENROLLMENT IN COAST GUARD APPROVED DRUG TESTING PROGRAM PER 46 CFR PART 16. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Construction/Loadline
Issued 17 June 1994 Resolved
PROVIDE DRAFT OR LOADING MARKS ON VESSEL'S HULL PER 46 CFR 185.30-(B)(1) AND (2).
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Fire Fighting
Issued 17 June 1994 Resolved
PROVE PROPER OPERATION OF VESSEL'S FIRE PUMP. UNTIL REQUIREMENT CLEARED THEVESSEL'S FIRE PUMP IS TO BE OPERATED DAILY WITH WATER DISCHARGED FROM THE UPPER DECK FIRE STATION. AN ADEQUATE STREAM OF WATER AND PRESSURE SHALL BE NOTED BEFORE SECURING THE PUMP FOR THE DAY.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Construction/Loadline
Issued 27 May 1994 Resolved
LABEL DOORS ON VESSEL LEADING OVERBOARD AS FOLLOWS: "DANGER-KEEP CLOSED, CREW USE ONLY".
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Fire Fighting
Issued 27 May 1994 Resolved
MOUNT FIRE AXE IN AN ACCESSIBLE LOCATION NEAR THE WHEELHOUSE,
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Lifesaving
Issued 27 May 1994 Resolved
PROVIDE A BOATHOOK FOR MAN OVERBOARD DRILLS AND EMERGENCIES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Navigation
Issued 27 May 1994 Resolved
DOUBLE NUT/COTTER PIN STEERING GEAR JOCKEY BAR CONNECTIONS PORT AND STBD SIDES.
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Electrical
Issued 27 May 1994 Resolved
PROVIDE PROPER COVERS FOR JUNCTION BOXES ON TOP OF THE WHEELHOUSE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Lifesaving
Issued 27 May 1994 Resolved
EMERGENCY CHECK OFF LIST TO BE POSTED ON ALL DECKS ACCESSIBLE TO PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Lifesaving
Issued 27 May 1994 Resolved
LABEL ALL TRIP HAZARDS THROUGHOUT VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Construction/Loadline
Issued 27 May 1994 Resolved
LABEL UPPER DECK CAPACITY PER STABILITY LETTER. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Lifesaving
Issued 27 May 1994 Resolved
LABEL VESSEL NAME ON ALL CHILD PFDS.
Condition: Unknown
Due 27 June 1994
Resolved 21 June 1994
Lifesaving
Issued 27 May 1994 Resolved
PROVIDE ONE ADDITIONAL CHILD PFD TO RAISE COMPLEMENT TO 16 PER COI. AN APPROVED PFD SHALL BE AVAILABLE TO ALL CHILDREN CARRIED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1994
Resolved 21 June 1994
Fire Fighting
Issued 27 May 1994 Resolved
PROVIDE PROPER FIRE HOSE NOZZLES PER 46 CFR 181.15-10(C)(2)._x001C_
Condition: Unknown
Due 10 June 1994
Resolved 21 June 1994
Lifesaving
Issued 27 May 1994 Resolved
SAFETY ORIENTATION FOR VESSEL TO BE DEVELOPED PRIOR TO CARRIAGE OF PASSENGERS BUT NO LATER THAN 10JUN94._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 June 1994
Resolved 1 June 1994
Electrical
Issued 27 May 1994 Resolved
HIGHWATER TEMPERATURE SENSOR FOR GENERATOR TO BE REPLACED AND TESTED SATISFACTORY PRIOR TO CARRIAGE OF PASSENGERS BUT NOT LATER THAN 10JUN94.
Condition: Unknown
Due 10 June 1994
Resolved 1 June 1994

Ownership record