Records from 1998 to 2000. Most recent: inspection, 12 September 2000.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Deck/Cargo
Issued 12 September 2000
Resolved
Repair #1 crane pedestal access hatch._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 November 2000
Resolved 15 November 2000
Engineering
Issued 12 September 2000
Resolved
Provide attestation to configuration as built/installed, and prove proper operation of OWS. Prior to departure from the Port of Houston. ( IAW MARPOL 73/78 Annex I/16 )
Condition: Unknown
Due 12 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 12 September 2000
Resolved
Repair/prove operation of vessel's fire detection system._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 November 2000
Resolved 25 November 2000
Fire Fighting
Issued 12 September 2000
Resolved
Repair frozen reach rod to emergency fire pump in forecastle._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 November 2000
Resolved 25 November 2000
Deck/Cargo
Issued 12 September 2000
Resolved
Cargo crane grease fittings painted over, indicating lack of proper lubri-_x001C_cation and maintenance in accordance with manufacturer's recommendations._x001C_ Correct to the satisfaction of USCG inspector NLT 14OCT00._x001C_ ( IAW SOLAS 74 AMD/ I/11 )
Condition: Unknown
Due 9 November 2000
Resolved 15 November 2000
Lifesaving
Issued 12 September 2000
Resolved
Degradation of lifesaving and firefighting euipment indicative of improper maintenance and lack of training. Conduct fire and boat drill to the satisfaction of USCG inspector. ( IAW SOLAS 74 AMD/ III/18 )
Condition: Unknown
Due 9 November 2000
Resolved 15 November 2000
Construction/Loadline
Issued 12 September 2000
Resolved
Bulkhead openings for portable A/C units and other misc. openings, and guard rails not weathertight. Repair to the satisfaction of certificate issuing authority NLT 12OCT00. (IAW ILLC 66 Annex I/15)
Condition: Unknown
Due 9 November 2000
Resolved 15 November 2000
Construction/Loadline
Issued 12 September 2000
Resolved
Main outlets/inlets of numerous ventilation ducts are frozen/wasted, and _x001C_ are incapable of being closed. Repair/replace all ventilation closure devices to satisfaction of certificate issuing authority and USCG inspectorprior to departure from Port Houston. ( IAW SOLAS 74 AMD/ III/19 )
Condition: Unknown
Due 9 November 2000
Resolved 15 November 2000
Lifesaving
Issued 12 September 2000
Resolved
General house keeping of E/R spaces are in poor condition. Remove excess oil residue from deck plates and handrails on all levels of E/R prior to departure from the Port of Houston. [ (IAW SOLAS 74 AMD I/11 (a) ]
Condition: Unknown
Due 12 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 12 September 2000
Resolved
Missing sprinkler system spray nozzle located in the shipper's room (bos'n hole). Correct to the satisfaction of USCG inspector NLT 14OCT00._x001C_ ( IAW SOLAS 74 AMD/ I/11 )
Condition: Unknown
Due 14 October 2000
Resolved 8 November 2000
Electrical
Issued 12 September 2000
Resolved
Excessive exhaust leaks from the S/S generator. Make repairs prior to departure from Port of Houston. ( IAW SOLAS 74 AMD/ II-1/26.1 )
Condition: Unknown
Due 12 September 2000
Resolved 15 September 2000
Lifesaving
Issued 12 September 2000
Resolved
Inadequate number of lifeboat rations due to removal of (4) rations that had lost their vacuum seal. Provide replacements prior to departure from the Port of Houston. ( IAW SOLAS 74 AMD/ III/41.8.12 )
Condition: Unknown
Due 12 September 2000
Resolved 25 November 2000
Deck/Cargo
Issued 12 September 2000
Resolved
Repair/prove operation of all cargo crane limit switches._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 November 2000
Resolved 15 November 2000
Lifesaving
Issued 12 September 2000
Resolved
Port/starboard lifeboats have numerous structural, mechanical, and propul-_x001C_sion deficiencies. Completely strip out and conduct survey. Make repairs tothe satisfaction of certificate issuing authority and USCG inspector prior_x001C_to departure from Port Houston. ( IAW SOLAS 74 AMD/ III/19 )
Condition: Unknown
Due 14 September 2000
Resolved 1 October 2000
Fire Fighting
Issued 12 September 2000
Resolved
Repair leaking packing on emergency fire pump._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 November 2000
Resolved 25 November 2000
Construction/Loadline
Issued 8 September 2000
Resolved
MAKE PERMANENT REPAIRS TO VENTILATION COVER GASKETS AND DOOR GASKETS THROUGHOUT THE VESSEL._x001C_ ICLL 66 I/16
Condition: Unknown
Due 15 November 2000
Resolved 15 November 2000
Navigation
Issued 8 September 2000
Resolved
MAKE PERMANENT REPAIRS TO THE ECHO SOUNDER CHART RECORDER PRIOR TO DEPARTING THE HOUSTON-GALVESTON COTP ZONE._x001C_ 33 CFR 164.35(i)
Condition: Unknown
Due 16 September 2000
Resolved 8 November 2000
Accommodation/Occupational Safety
Issued 8 September 2000
Resolved
REMOVE INSECTS FROM GALLEY AND FOOD STORAGE (DRY STORES) AREAS PRIOR TO DEPARTING THE HOUSTON-GALVESTON COTP ZONE.
Condition: Unknown
Due 16 September 2000
Resolved 8 November 2000
Construction/Loadline
Issued 8 September 2000
Resolved
REMOVE PAINT FROM INVALID LOAD LINE MARKINGS._x001C_ ICLL I/8
Condition: Unknown
Due 8 October 2000
Resolved 8 November 2000
Electrical
Issued 8 September 2000
Resolved
REPAIR EXPLOSION PROOF LIGHTING IN BATTERY ROOM FOR THE RADIOS._x001C_ SOLAS 60 II/27(C)
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Engineering
Issued 8 September 2000
Resolved
PROVIDE CLASSIFICATION SOCIETY REPORT ATTESTING TO THE PROPER PIPING AND VALVE ARRANGEMENT FOR DIVERTING OVERBOARD FLOW ON NON-COMPLIANT OILY WATER STREAM AND PROVE PROPER OPERATION OF THE OWS. (AUTOMATIC SHUT OFF VALVE APPEARS TO BE PLACED IN A POSITION THAT WOULD NOT DIVERT >15PPM OILY WATER.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 8 September 2000
Resolved
REMOVE FLAMMABLE MATERIALS (PAINT CANS) FROM REEFER SPACE._x001C_ SOLAS 74/78 (AMD) II-2/18.7
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 8 September 2000
Resolved
MAKE PERMANENT REPAIRS TO EMERGENCY LIGHTING. LIGHTING SYSTEM NOT OPERATIONAL._x001C_ SOLAS 60 III/38
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Electrical
Issued 1 September 2000
Resolved
EXCESSIVE LEAKAGE FROM GENERATOR COOLING SEA WATER PUMP._x001C_ (SOLAS 60, REG I/11)
Condition: Unknown
Due 25 November 2000
Resolved 25 November 2000
Lifesaving
Issued 27 August 2000
Resolved
Make operational limit switches on life boat davits (port and starboard) prior to departure from the Port of Tampa.
Condition: Unknown
Due 27 August 2000
Resolved 29 August 2000
Lifesaving
Issued 27 August 2000
Resolved
Prior to departing the Port of Tampa exercise starboard lifeboat, SOLAS 74 III/18.3.
Condition: Unknown
Due 27 August 2000
Resolved 30 August 2000
Fire Fighting
Issued 27 August 2000
Resolved
Portable fire extinguishers to be periodically examined and tested as to the Administration's requirments SOLAS 74 II-2/6.5, and log tests as required tested as per SOLAS 74 II-2/20.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 27 August 2000
Resolved
Replace lines on lifebuoys with buoyant line, correct prior to return to U.S. after current voyage, but not later than 27Sep00.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Deck/Cargo
Issued 27 August 2000
Resolved
Various hydraulic leaks on deck machinery and piping, repair piror to return to the U.S. but not later than 27SEP00, SOLAS 60 I/11.
Condition: Unknown
Due 8 November 2000
Resolved 8 November 2000
Electrical
Issued 27 August 2000
Resolved
Various light fixtures on deck and in the cargo holds are without covers and missing bulbs. Repair prior to the next U.S. voyage but not later than27SEP00.
Condition: Unknown
Due 8 November 2000
Resolved 8 November 2000
Construction/Loadline
Issued 27 August 2000
Resolved
Dogs missing from various closure devices throughout the ship, correct prior to returning to the U.S. but not later than 27Sep00.
Condition: Unknown
Due 8 November 2000
Resolved 8 November 2000
Construction/Loadline
Issued 27 August 2000
Resolved
Make repairs to wasted brackets inboard cargo hold #4 (main deck) and evaluate other holds, correct prior to returning to the U.S.
Condition: Unknown
Due 8 November 2000
Resolved 8 November 2000
Fire Fighting
Issued 27 August 2000
Resolved
Cargo hold #3 heat detector disconnected, vent ducts crushed and ladder rusted away, repair to satisfaction of Administration, prior to returning_x001C_ to the U.S.
Condition: Unknown
Due 31 March 2001
Resolved 15 November 2000
Lifesaving
Issued 27 August 2000
Resolved
Prior to departure, witness satisfactory operation of the starboard side lifeboat engine.
Condition: Unknown
Due 28 August 2000
Resolved 29 August 2000
Construction/Loadline
Issued 27 August 2000
Resolved
Have class society evaluate the condition of the boat deck (embarkation deck) in the vicinity of the life rafts, prior to returning the U.S.
Condition: Unknown
Due 8 November 2000
Resolved 8 November 2000
Documentation
Issued 28 June 1998
Resolved
Provide lifesaving appliances maintenance manual IAW SOLAS 74, III/19&25.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Lifesaving
Issued 28 June 1998
Resolved
Repair limit switches on port and starboard lifeboats IAW SOLAS 74, VI/48.2.5.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Documentation
Issued 28 June 1998
Resolved
Provide Administration approved Cargo Securing Manual IAW SOLAS 74, VI/5.
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000
Lifesaving
Issued 28 June 1998
Resolved
Install weak links on port and starboard liferafts IAW SOLAS 74, III/26.3.1
Condition: Unknown
Due 28 August 2000
Resolved 28 August 2000