Records from 1995 to 1997. Most recent: inspection, 23 June 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline
Issued 23 June 1997
No resolution recorded
PROVIDE CLOSURE AND GASKET FOR ALL MAINDECK BALLAST TANK VENTS._x001C_ ILLC 66 I/18
Condition: Unknown
Due 27 June 1997 — due date passed with no resolution recorded
Fire Fighting
Issued 23 June 1997
Resolved
PROVIDE A FIRE EXTINGUISHER OUTSIDE OF THE BOATSWAINS STORE ROOM ON MAIN DECK FORWARD._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Construction/Loadline
Issued 23 June 1997
No resolution recorded
RENEW THE GASKET AND FREE UP THE DOOR TO THE ELECTRICAL LOCKER ON MAIN DECKFORWARD, STARBOARD SIDE._x001C_ ILLC 66 I/18
Condition: Unknown
Due 27 June 1997 — due date passed with no resolution recorded
Fire Fighting
Issued 23 June 1997
Resolved
PROVIDE 5 HOSES AND NOZZLES FOR THE ACCOMODATION SPACE._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Lifesaving
Issued 23 June 1997
Resolved
PROVIDE ON BOARD A SUFFICIENT QUANTITY OF WATER STORED IN EACH LIFEBOAT IN A WATERTIGHT CONTAINER._x001C_ SOLAS 74 (AMENDED) III 41.8
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Lifesaving
Issued 23 June 1997
Resolved
PLACE ALL LIFEBOAT STORES AND EQUIPMENT IN THE PORT AND STARBOARD LIFEBOATSIN A WEATHERTIGHT CONTAINER._x001C_ SOLAS 60 III/11
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Fire Fighting
Issued 23 June 1997
Resolved
PROVIDE A FIRE EXTINGUISHER OUTSIDE OF THE STEERING GEAR ROOM._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Accommodation/Occupational Safety
Issued 23 June 1997
Resolved
FUMIGATE AND PROVIDE EXTRA FUMIGANTS FOR THE CREW AND OFFICERS GALLEY.
Condition: Unknown
Due 26 June 1997
Resolved 27 June 1997
Accommodation/Occupational Safety
Issued 12 June 1996
Resolved
PRIOR TO RETURN TO U.S., PROVIDE IMO APPROVAL/CERTIFICATION OF VSL MSD.
Condition: Unknown
Due 14 June 1996
Resolved 13 June 1996
Documentation
Issued 12 June 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Electrical
Issued 12 June 1996
Resolved
PRIOR TO RETURN TO U.S., PROVIDE CLASS ATTESTATION TO ARRANGEMENT/CONDITIONOF #1 SHIPS SERVICE GENERATOR- INOPERATIVE DUE TO MAINTAINANCE/REPAIR.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Lifesaving
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION TO GENERAL CONDITION OF STARBOARD LIFEBOAT WHERE PATCHED AND SEATS DECAYED (WOOD).
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Engineering
Issued 12 June 1996
Resolved
PRIOR TO RETURN TO U.S., PROVIDE CLASS ATTESTATION TO CONDITION OF MAIN ENGINE FRESHWATER COOLING PUMP- DISCONNECTED.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Navigation
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, PROVIDE U.S. COAST PILOT (EAST COAST, BA #69) WITH CURRENT CORRECTIONS.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION TO CONDITION OF ALL PORTABLE FIRE EXTINGUISHERS ON BOARD.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION TO SATISFACTION WITH REPAIRS TO THE EMERGENCY FIREPUMP DISCHARGE LINE IN WAY OF DOUBLER.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, PROVIDE CLASS ATTESTATION AS TO THE GENERAL CONDITION OF THE MAIN FIRE FIGHTING SYSTEM IN THE LOWER LEVEL OF THE ENGINE ROOM.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, EFFECT PERMANENT REPAIRS AND PROVIDE CLASS ATTESTATION AS TO THE CONDITION OF THE #1 MAIN FIREPUMP.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, EFFECT PERMANENT REPAIRS TO THE EMERGENCY FIREPUMP EXHAUST SYSTEM WHERE LEAKING.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Engineering
Issued 12 June 1996
Resolved
PRIOR TO DEPARTURE, DEMONSTRATE PROPER OPERATION OF THE OILY WATER SEPARATOR.
Condition: Unknown
Due 14 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 19 June 1995
Resolved
MAKE PERMANENT REPAIR TO FIREMAIN AFT DECK FORWARD OF 90 DEG BEND DOWNWARD.
Condition: Unknown
Due 28 August 1996
Resolved 28 August 1996
Unknown
Issued 19 June 1995
Resolved
REMOVE WASTED 55 GALLON DRUMS OF PAINT WASTE FROM STERN.
Condition: Unknown
Due 20 June 1995
Resolved 8 July 1995
Fire Fighting
Issued 19 June 1995
Resolved
PROVIDE TWO FIRE HOSES FOR FORWARD FIRE STATIONS.
Condition: Unknown
Due 20 June 1995
Resolved 8 July 1995
Navigation
Issued 19 June 1995
Resolved
PROVIDE, FOR THE AREA TRANSITTED, CHART #3848.
Condition: Unknown
Due 20 June 1995
Resolved 8 July 1995
Navigation
Issued 19 June 1995
Resolved
PROVIDE COAST GUARD LIGHT LIST.
Condition: Unknown
Due 20 June 1995
Resolved 8 July 1995