MAURY USCG vessel records Sign in
← All vessels

BABY BLUE

BABY BLUE is a 1994 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1994, most recently in September 2024, along with 80 deficiencies.

Records from 1994 to 2024. Most recent: inspection, 4 September 2024.

Built
1994
Last inspected
4 September 2024
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3036
400405
Flag
UNITED STATES
367764120
Maury page id
psix-400405

Inspections, by type

…with no type recorded2
Years with a record 28 calendar years (1994–2024)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.0 ft × 5.0 ft
Registered tonnagegross 10 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMORGAN BOATS INC · NAPLES, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPERDIDO KEY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Net Ton
10 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3036MMSI 367764120 · active · compulsorily equipped · granted 3 December 2016, expires 3 December 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDE3288MMSI 367336870 · expired · compulsorily equipped · granted 9 February 2008, cancelled 14 April 2018 · licensed under a name not among this hull’s recorded names (not shown)
WCS4502MMSI not assigned · expired · compulsorily equipped · granted 14 June 1995, cancelled 20 August 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

4 September 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7996041
25 April 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7675570
3 March 2022 Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7405686
7 February 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393704
15 June 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7226155
7 May 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7163031
1 May 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6951314
21 February 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6912997
13 February 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6625112
21 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6419548
28 March 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6380186
25 January 2018 Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6343803
10 May 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6143132
20 January 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6074271
10 March 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5831016
10 February 2016 Hull Examination · COI Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5813067
21 August 2015 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5222461
31 January 2012 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4226240
14 February 2011 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3936982
4 March 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3688094
4 February 2010 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3675119
20 February 2009 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3420996
5 February 2009 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3393794
21 November 2008 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3367002
14 February 2008 Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147114
23 January 2008 Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3130965
17 September 2007 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3065487
2 November 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2526821
4 October 2004 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2212691
28 September 2004 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2192084
1 August 2004 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2183207
29 August 2003 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1875748
13 August 2003 In-Service Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1874767
10 August 2003 In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1872801
21 May 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1798028
5 September 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1671587
18 June 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1447119
3 May 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384755
23 May 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418694
22 June 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1408326
11 May 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798328
20 April 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1449163
23 April 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1409895
9 June 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775207
9 May 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1102874
24 April 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1095946
1 May 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1085100
10 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1079550
19 December 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183340
30 November 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 870740
21 February 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160873
22 April 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1159581
7 February 1994 Plan Review "T" Boat · Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1148846

Deficiency record · 80

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 April 2023 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. The new name of the vessel was not marked on any life jackets. Properly label all life jackets with new vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 10 May 2023
Resolution: Life jackets labeled
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 26 April 2023 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Visual alarm was not operating and audible alarm was not sufficient to hear clearly. Repair or replace bilge high water alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 10 May 2023
Resolution: High level alarm repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2023 Resolved
The words "FIRE BUCKET" must be stenciled in a contrasting color on each fire bucket. The stencil on fire buckets has faded and illegible. Re-stencil fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 10 May 2023
Resolution: Fire buckets properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2023 Resolved
Fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve. Fuel shutoff valves were not marked. Properly mark location of fuel shutoff valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 10 May 2023
Resolution: Fuel shut off properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 February 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have an audible alarm that sounds upon discharge and a means to reset devices used to automatically shut down ventilation systems and engines at the operating station. Install proper audible alarm and means to reset shutdown devices (override switch) at the operating station for Fireboy system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2022
Resolution: Audible alarm and override switch installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2022 Resolved
A vessel must be provided with an auxiliary means of steering (hand tiller) capable of moving the rudder. Captain was unable to disengage main steering in order to utilize hand tiller. Provide means to operate steering system with hand tiller.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2022
Resolution: Hand tiller operating sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2021 Resolved
Aft bilge pump did not work in automatic mode.
Due 3 August 2021
Resolved 10 February 2022
Resolution: Bilge pump operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2021 Resolved
Bilges had excessive water, pump out prior to next inspection.
Due 3 August 2021
Resolved 10 February 2022
Resolution: Bilges clean
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 July 2021 Resolved
Run sufficient drills to train crew proficiently for operations.
Due 3 August 2021
Resolved 10 February 2022
Resolution: New crew ran satisfactory drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2021 Resolved
Post donning placard for lifejackets onboard.
Due 3 August 2021
Resolved 10 February 2022
Resolution: proper donning placard posted on board
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 May 2020 Resolved
Vessel captain could not provide MMC and medical at time of inspection. Provide evidence captain has current MMC and medical certificates
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2020
Resolution: Submitted photo with current MMC and medical
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 5 May 2020 Resolved
Vesssls VHF radio installation not programmed with MMSI nor GPS. Provide evidence the VHF radio stallation is programmed correctly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2020
Resolved 2 June 2020
Resolution: recieved pictures, ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2020 Resolved
Main engines were inoperable at the time of inspection; parts for engine are on order. Prove proper operation of main engine.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2022
Resolution: Engine operational test sat
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 March 2019 Resolved
FCC Safety certificate not onboard, provide valid certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2019
Resolution: Provided copy of required certificate
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 March 2019 Resolved
US Coast Pilot, CG Light List, Tide tables not onboard. Provide updated publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2019
Resolution: Provided picture evidence of updated publications
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 26 March 2019 Resolved
Battery connection was made with wing nuts. Make connection using permanent type connectors.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2019
Resolution: Provided picture evidence of permanent type connectors on battery installation.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 April 2018 Resolved
Provide proof of supervisor training for DAPI program.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 17 May 2018
Resolution: Provided Alcohol test kit.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 April 2018 Resolved
Obtain alcohol test strips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 17 May 2018
Resolution: Provided alcohol test kit.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 April 2018 Resolved
Provide proof of marine radio operator’s permit for FCC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 17 May 2018
Resolution: Provided Marine op. permit.
Fire Fighting › Fire Bucket › Capacity
Issued 18 April 2018 Resolved
Vessel must have 03 2.5 gallon fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 17 May 2018
Resolution: Provided appropriate fire buckets.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 April 2018 Resolved
Vessel must have emergency instructions posted on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2018
Resolved 17 May 2018
Resolution: Emergency instructions posted.
Lifesaving › Hand Flares › Quantity
Issued 9 February 2017 Resolved
Only 04 red hand flares on board, ensure the proper number of required signaling devices are on board for route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 10 May 2017
Resolution: Proper number of unexpired flares on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 February 2017 Resolved
Child lifejackets must be stowed separate from adult life jackets. Ensure stowage for child life jackets are appropriately marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 10 May 2017
Resolution: Lifejackets properly stowed and marked.
Fire Fighting › Fire Bucket › Quantity
Issued 9 February 2017 Resolved
Vessel must have 3 2.5 gal buckets with an attached lanyard labled "fire bucket"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 10 May 2017
Resolution: 3 fire buckets with proper markings on board.
Navigation › Piloting/Steering › Marine Charts
Issued 9 February 2017 Resolved
provide updated charts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 10 May 2017
Resolution: Updated navigation charts provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 February 2017 Resolved
Insure all required items in first aide kits are not expired
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 10 May 2017
Resolution: Renewed contents of Medical Kit.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 February 2017 Resolved
Ensure all lifejackets carried onboard are USCG approved. One adult lifejacket does not meet 46 CFR 160.055 IAW 46 CFR 180.71. Vessel may not carry 23 total persons on board until lifejacket is replaced.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 March 2017
Resolved 10 May 2017
Resolution: Proper number of Type I life jackets provided.
Documentation › Certificates/Documents › FCC SSL
Issued 22 February 2016 Resolved
Neither the owner or master could provide a marine radio operator permit. The vessel shall not operate no more than 1000 ft from shore, until a marine radio operator permit is provided. 47 CFR 80.159
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Resolution: Provided proof of completing test for Marine Operators Permit.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 22 February 2016 Resolved
Vessels RPM gauge was inoperable. Prove proper operation to the attending Marine Inspector. 46 CFR 182.410(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Resolution: RPM gauge installed and tested.
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 February 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Resolution: Owner provided proper charts and pubs.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 February 2016 Resolved
Vessels anchor light was obstructed from view. Provide a all-around white light, clearly visible from all directions. 33 CFR 83.30(b)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2016
Resolved 10 March 2016
Resolution: Newly installed all around nav light on the stern installed and checked.
Documentation › Certificates/Documents › FCC SSL
Issued 14 February 2008 Resolved
Provide a FCC radio station license
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Documentation › Certificates/Documents › FCC SSL
Issued 14 February 2008 Resolved
Provide a radio safety telephoney certificate
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 February 2008 Resolved
Provide current copies of the tides and current tables
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 14 February 2008 Resolved
Provide a FCC operators license for the master of the vessel
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Engineering › Bilge Water Management System › Pump
Issued 14 February 2008 Resolved
Provide an audible and visual indicators for all high bilge alarms at the operating station.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Engineering › Bilge Water Management System › Pump
Issued 14 February 2008 Resolved
Demonstrate proper operation of the starboard automatic bilge pump indicating light.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Engineering › Steering Gear System › Trick Wheel
Issued 14 February 2008 Resolved
Demonstrate proper operation of the emergency hand tiller for the steering system.
Action required: 705 - Other - as specified
Due 14 March 2008
Resolved 4 March 2008
Construction/Loadline › Hull › Hull Plating
Issued 23 January 2008 Resolved
Grind and reglass approximately 3 " crack in bow located under rub rail as per 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 14 February 2008
Resolution: The crack in the bow under the rub rail was reglassed.
Construction/Loadline › Hull › Side Shell
Issued 23 January 2008 Resolved
Grind and reglass area where deck connects to hull in both freeing ports on stern of vessel as per 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 14 February 2008
Resolution: The fracture in way of the deck and transom was reglassed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 23 January 2008 Resolved
Grind and reglass two cracks on aft corners on hatch opening leading to engine as per 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 14 February 2008
Resolution: The fractures in the coaming for the engine cover were reglassed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 January 2008 Resolved
Properly secure third seat from front on starboard side as per 46 CFR 176.610; current arrangement is missing bolts.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 14 February 2008
Resolution: The loose seat was properly secured.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 January 2008 Resolved
Properly secure all deck railing as per 46 CFR 177.900; current arrangement is missing at least one bolt on starboard aft portion of railing.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 14 February 2008
Resolution: The loose rails were properly secured.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 November 2005 Resolved
Vessel is reduced to 21 passengers until full compliment of lifejackets is provided to make 32. Life jackets are to be provided no later that 04 NOV 05.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 18 November 2005
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2005 Resolved
Provide testing procedures for Serious Marine Incident testing and evidence of an Employee Assistance program.
Action required: 705 - Other - as specified
Due 2 December 2005
Resolved 18 November 2005
Documentation › Logs/Records › Logbook (official)
Issued 2 November 2005 Resolved
Provide current training logbook with description of drills and log 3 emergency drills (fire, abandon ship, and man overboard).
Action required: 705 - Other - as specified
Due 16 November 2005
Resolved 18 November 2005
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 28 September 2004 Resolved
PROVIDE PROOF THAT MIS REPORT WAS SUBMITTED FOR FY2003.
Due 10 October 2004
Resolved 28 September 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 10 September 2004 Resolved
DE-RUST AND SERVICE OR RENEW FIXED HALON SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2004
Resolved 28 September 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 September 2004 Resolved
PROVIDE A COMPLETE CG APPROVED FIRST AID KIT ONBOARD VESSEL.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2004
Resolved 28 September 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 September 2004 Resolved
PROVIDE A 6' NON-KINKING, UV RESISTANT FLOATING LINE FOR THE RING BOUY.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 October 2004
Resolved 28 September 2004
Construction/Loadline › Hull
Issued 26 August 2003 Resolved
Properly repair nicks/gouges in bow gelcoat/glass. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2003
Resolved 29 August 2003
Engineering › Shafting/Propeller Arrangements
Issued 26 August 2003 Resolved
Renew/repair wasted propeller. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2003
Resolved 29 August 2003
Construction/Loadline › Hull
Issued 26 August 2003 Resolved
Properly repair nicks/guages in way of port stern corner of sideshell. LEGACY COMPONENT DESC: Side Shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2003
Resolved 29 August 2003
Construction/Loadline › Structures
Issued 26 August 2003 Resolved
Renew 5 white weather tight hatches with broken hinges. LEGACY COMPONENT DESC: Manhole
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2003
Resolved 29 August 2003
Resolution: Two of new hatches suffered broken hinges due to sealant clogging hinge recess. Replacements taken from PANTHER II were installed.
Construction/Loadline › Structures
Issued 26 August 2003 Resolved
Properly repair starboard bulwark at stern connection where fractured. LEGACY COMPONENT DESC: Deck Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2003
Resolved 29 August 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 26 August 2003 Resolved
Label port emergency fuel shut-off valve access cover. LEGACY COMPONENT DESC: Valve
Due 26 September 2003
Resolved 29 August 2003
Construction/Loadline › Structures
Issued 26 August 2003 Resolved
Install access hatch to forward void space. LEGACY COMPONENT DESC: Manhole
Due 26 September 2003
Resolved 29 August 2003
Construction/Loadline › Structures
Issued 26 August 2003 Resolved
Remove cinder blocks blocking aft center scuppers. LEGACY COMPONENT DESC: Scupper
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2003
Resolved 29 August 2003
Construction/Loadline › Structures
Issued 26 August 2003 Resolved
Remove trash blocking port and starboard aft scuppers. LEGACY COMPONENT DESC: Scupper
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2003
Resolved 29 August 2003
Engineering › Sea-water System (primary cooling)
Issued 26 August 2003 Resolved
Renew seachest pipe and open valve for inspection. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2003
Resolved 29 August 2003
Construction/Loadline › Hull
Issued 13 August 2003 Resolved
Vessel dry-dock period was lapsed. Have a credit dry-dock performed by CG inspectors prior to operation. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 August 2003 Resolved
Complete annual servicing of all firefighting equipment prior to carriage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2003
Operations/Management › Drills/Instruction
Issued 13 August 2003 Resolved
Perform drills to demonstrate crew competency.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2003
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment
Issued 13 August 2003 Resolved
Remove oil/water from bilges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2003
Construction/Loadline › Structures
Issued 13 August 2003 Resolved
Repair/replace broken deck hatches prior to completion of credit dry-dock. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2003
Lifesaving › Lifebuoys
Issued 13 August 2003 Resolved
Renew and properly install buoyant tether to floatlight. LEGACY COMPONENT DESC: Stowage
Condition: Improper/Lack of Maintenance
Due 13 September 2003
Resolved 17 September 2003
Resolution: Completed.
Lifesaving › Lifejacket/PFD (General)
Issued 13 August 2003 Resolved
Renew retro-reflective tape on PFDs as needed. Numerous jackets have peeling and faded tape. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 13 September 2003
Resolved 17 September 2003
Resolution: Completed.
Accommodation/Occupational Safety › Medical/First Aid
Issued 13 August 2003 Resolved
Provide splinting material and tornequet for first aid kit.
Condition: Improper/Lack of Maintenance
Due 13 September 2003
Resolved 17 September 2003
Resolution: Homemade tornequet and splint on hand. Reccommended a better solution.
Electrical › Lighting (emergency)
Issued 13 August 2003 Resolved
Provide 2 flashlights.
Condition: Improper/Lack of Maintenance
Due 13 September 2003
Resolved 17 September 2003
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety
Issued 13 August 2003 Resolved
Replace missing screws in hand rail stanchions. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 13 September 2003
Resolved 29 August 2003
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 August 2003 Resolved
Automatic control wiring is deteriorated and disconected
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2003
Operations/Management › Drills/Instruction › Fire
Issued 10 August 2003 Resolved
Crew unable to demonstrate knowledge of firefighting procedures
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2003
Fire Fighting
Issued 3 May 2001 Resolved
Renew flex hose from fuel filter to engine with hose with adequate fittings.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Engineering
Issued 3 May 2001 Resolved
Repair leak on Exhaust system.
Condition: Unknown
Due 15 May 2001
Resolved 15 May 2001
Construction/Loadline
Issued 20 April 1999 Resolved
VESSEL TO PROVIDE HIGH LEVEL ALARMS PRIOR TO 11MAY99_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 1999
Resolved 20 April 1999
Documentation
Issued 9 May 1997 Resolved
PROVIDE A PROCESS TO MANTAIN ALL REQUIRED LETTERS AND DOC. ONBOARD.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Unknown
Issued 9 May 1997 Resolved
PROVIDE E.A.T. FOR ALL CAPTAINS.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Fire Fighting
Issued 9 May 1997 Resolved
PROVIDE THREE FIRE BUCKETS.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Fire Fighting
Issued 30 November 1995 Resolved
Prove the operation of automatic shutdown, upon discharge of engine compartment halon cylinder.
Condition: Unknown
Due 30 November 1995
Resolved 30 November 1995
Lifesaving
Issued 21 February 1995 Resolved
Provide approved waterlight for ring buoy. Attach via separate 18' lanyard.
Condition: Unknown
Due 6 March 1995
Resolved 6 March 1995

Ownership record