MAURY USCG vessel records Sign in
← All vessels

BAY POINT LADY

BAY POINT LADY is a 1977 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 1994, most recently in October 2019, along with 41 deficiencies.

Records from 1994 to 2019. Most recent: inspection, 16 October 2019.

Built
1977
Last inspected
16 October 2019
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE4220
400424
Flag
UNITED STATES
367350320 (licence lapsed)
Maury page id
psix-400424

Inspections, by type

…with no type recorded2
Years with a record 20 calendar years (1994–2019)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.1 ft × 14.9 ft × 5.7 ft
Registered tonnagegross 28 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIFLITE INC · BELLINGHAM, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Net Ton
28 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK4721MMSI 367350320 · expired · compulsorily equipped · granted 11 September 2018, cancelled 11 May 2019
WDE4220MMSI 367350320 · expired · compulsorily equipped · granted 18 April 2008, cancelled 23 June 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 36

16 October 2019 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6843737
14 November 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580461
8 August 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6504943
16 August 2017 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6228305
11 January 2017 Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6065999
17 October 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6021243
14 September 2016 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6000468
15 August 2011 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4113503
8 February 2011 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3964965
8 February 2010 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3673465
23 April 2008 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3186532
8 February 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3144034
24 August 2006 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2759526
3 March 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2599397
20 May 2005 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2363056
24 August 2004 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2175905
19 May 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2064661
18 August 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1879497
18 August 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1882854
23 August 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1666428
20 May 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1618914
9 November 2001 Administrative
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1077298
24 August 2001 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1448340
22 May 2000 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1408570
26 July 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434918
9 March 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1353042
23 July 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427555
22 May 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462663
22 May 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1452292
23 July 1996 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 10605
25 June 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1466429
23 May 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1417962
22 June 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1392250
16 June 1995 Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1187061
24 May 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 869379
24 May 1994 Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171749

Deficiency record · 41

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 August 2018 Resolved
Provide updated and valid FCC station license. Vessel is restricted from operating more than 1000ft from shore.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 5 September 2018
Resolution: FCC station license onboard.
Lifesaving › Hand Flares › Expired
Issued 16 August 2017 Resolved
One red flare is out of date. Provide one red flare.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2017
Resolved 16 August 2017
Resolution: Provided.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 16 August 2017 Resolved
Vessel needs to clean the oil from the engine room compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 16 August 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 11 January 2017 Resolved
Replace forward scuttle due to approx two in crack
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 22 February 2017
Resolution: Vessel satisfactory repaired scuttle
Stability › Watertight Integrity › Coaming
Issued 11 January 2017 Resolved
Renew hatch coaming port side adjacent to console
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 22 February 2017
Resolution: Vessel renewed coaming
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 11 January 2017 Resolved
Clean bilges and make available for inspection
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 22 February 2017
Resolution: Vessel cleaned bilges
Engineering › Steering Gear System › Rudder
Issued 11 January 2017 Resolved
Perform satisfactory underway sea trial following leaking rudder repair that was identified during annual exam
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 January 2017
Resolved 22 February 2017
Resolution: Vessel conducted sat underway sea trial
Construction/Loadline › Penetrations › Gasket
Issued 17 October 2016 Resolved
Rudder post need new shaft packing or the rudder post to be tightened.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 11 January 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 October 2016 Resolved
Alcohol test equipment is not onboard and they go beyond 2hrs from shore based on there route.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 14 November 2016
Resolution: Alcohol test strips have been provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 September 2016 Resolved
Complete a credit annual exam. Vessel is overdue for annual exam as of 27Aug16
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2016
Resolved 22 February 2017
Resolution: Vessel completed annual
Construction/Loadline › Hull › Side Shell
Issued 8 February 2010 Resolved
Remove bottom coat and cracked/bad fiberglass and repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Construction/Loadline › Hull › Side Shell
Issued 8 February 2010 Resolved
Repair/Remove dive platform & fill holes with epoxy microblends.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Engineering › Shafting/Propeller Arrangements › Shaft Cone
Issued 8 February 2010 Resolved
Replace cutlass bearings and provide shaft log for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 February 2010 Resolved
Replace hydraulic lines for steering system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 8 February 2010 Resolved
Remove oil from engine room including electrical wiring and bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2010 Resolved
Remove wire from anchor locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Engineering › Sea-water System (primary cooling) › Valve
Issued 8 February 2010 Resolved
PMS gate valve for fire pump thru-hull fitting.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 April 2008 Resolved
Mount portable fire extinguishers, and repair fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 April 2008 Resolved
Tighten rudder packing on forward rudder post.
Due 23 May 2008
Resolved 28 April 2008
Communications › Radio Communications › EPIRB
Issued 23 April 2008 Resolved
Provide EPIRB with float free system.
Due 23 May 2008
Resolved 11 June 2008
Lifesaving › Lifefloat › Painter
Issued 24 August 2006 Resolved
Properly secure sea painter to body of life float as required by 46 CFR 180.137
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2006
Resolved 24 August 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 August 2006 Resolved
Provide a First Aid Kit approved under 46 CFR 160.041, or kit with equivalent contents and instructions, as required by 46 CFR 184.710
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2006
Resolved 24 August 2006
Lifesaving › Visual Distress Signals (General) › Condition
Issued 24 August 2006 Resolved
Provide 6 serviceable hand held red flare distress signals and smoke signals approved in accordance with 46 CFR 160.021 and .037as required by 46 CFR 180.68.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2006
Resolved 24 August 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 May 2005 Resolved
Provide a serviceable floating water light for life float (46 CFR 180.175).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2005
Resolved 20 May 2005
Lifesaving › Lifefloat › Paddle
Issued 20 May 2005 Resolved
Provide 2 each 4 foot paddles for life float, and mark with vessel name, and attach with suitable lanyard. (46 CFR 180.175).
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2005
Resolved 23 May 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 May 2005 Resolved
Provide suitable means to allow safe access to primary lifesaving equipment for crew during deployment. (46 CFR 177.800).
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 23 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 20 May 2005 Resolved
Replace wasted/brittle flex hose assemblies on propulsion engine primary fuel oil filter inlet. (46 CFR 182.720).
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 23 May 2005
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 May 2005 Resolved
Make machinery space ventilation duct closures vapor tight. (46 CFR 177.405)
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 23 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 May 2005 Resolved
Provide and demonstrate proper operation of visual indicator for bilge high level alarm (46 CFR 182.530).
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 23 May 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 May 2005 Resolved
Repair mechanical guard on exhaust pipe in under seat storage compartment, port side, main deck. (46 CFR 177.960).
Action required: 705 - Other - as specified
Due 20 June 2005
Resolved 23 May 2005
Documentation › Certificates/Documents › FCC SSL
Issued 24 August 2004 Resolved
Provide FCC safety certificate prior to operating beyond 1000 feet from shore.
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 24 August 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 24 August 2004 Resolved
Renew B-I fire extinguisher IAW 46 CFR 176.810 prior to carrying passengers for hire or prior to 25 SEP 04.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2004
Resolved 24 August 2004
Construction/Loadline › Structures › Deck Plating
Issued 24 August 2004 Resolved
Repair deck fiberglass cover.
Action required: 705 - Other - as specified
Due 25 September 2004
Resolved 24 August 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 24 August 2004 Resolved
Repair engine shutdown at control station IAW 46 CFR 182.200 prior to carrying passengers for hire or prior to 25 SEP 04.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2004
Resolved 24 August 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 August 2003 Resolved
Renew lifejacket donning placard IAW 46 CFR 185.615. LEGACY COMPONENT DESC: Donning Placard
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2003
Resolution: Owner renewed lifejacket donning placard.
Lifesaving › Lifebuoys
Issued 18 August 2003 Resolved
Renew retro tape on life ring IAW 46 CFR 185.604. LEGACY COMPONENT DESC: Retro Material
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2003
Resolved 18 August 2003
Resolution: Owner renewed retro tape on life ring.
Lifesaving › Lifebuoys
Issued 18 August 2003 Resolved
Renew line on life ring IAW 46 CFR 180.70. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2003
Resolution: Owner renewed line on lifering.
Lifesaving
Issued 23 July 1998 Resolved
Aspirin in first aid kit expired.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Navigation
Issued 23 July 1998 Resolved
Emergency broadcast placard not posted.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998 Resolved
Oil pollution discharge placard deteoriated and unreadable._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 23 July 1998 Resolved
50% of crew not currently first aid or CPR certified.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.