Records from 1994 to 2007. Most recent: inspection, 4 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
4 December 2007
Type not recorded
No type recorded · USCGC BONITO (WPB 87341) · USCG Northeast District (CGD-NE) · Activity 3109869
26 November 2007
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3104328
30 January 2007
Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2864148
30 January 2006
ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2576175
25 May 2005
ILO-147 Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2367710
6 May 2005
ILO-147 Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2350622
16 September 2004
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2177591
3 June 2003
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1808727
24 May 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1800441
21 May 2003
Special Interest Vessel
Type not classified · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1805891
20 July 2001
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 292116
29 April 2001
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 289677
15 April 2001
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 288886
26 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 392504
3 August 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 688552
24 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 366971
24 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1171829
Construction/Loadline › Structures › Superstructure
Issued 10 December 2007
No resolution recorded
Fracture located on the starboard side of the vessel, where the catwalk/deck for accommodation ladder winch is located. the fracture is where the deck joins the superstructure on the outboard side. this fracture appears to be contained to this joint. Repair to the satisfaction of Class.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Electric Generation Source (emergency) › Generator
Issued 30 January 2007
Resolved
Emergency generator, #4 cylinder, head gasket is leaking cooling water. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2007
Resolution: LEAK HAS BEEN REPAIRED
Engineering › Fuel Oil Service System › Piping
Issued 30 January 2007
Resolved
Steamline for fuel oil heating, next to the Oily Water Separator is leaking excessively. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2007
Resolution: leak Has been repaired
Engineering › Lubricating Oil Service System › Purifier
Issued 30 January 2007
Resolved
Lube oil heater #1 for main engine is leaking excessively. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 December 2007
Resolution: Leak has been repaired
Lifesaving › Lifeboat › Hull
Issued 6 May 2005
Resolved
Port lifeboat has damage/fracture on upper right corner of transom. Repair as original to the satisfaction of class society surveyor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 12 May 2005
Resolution: Class report received. Class states the lifeboat has been repaired and found satisfactory.
Engineering › Sea-water System (primary cooling) › Valve
Issued 6 May 2005
Resolved
Main saltwater cooling valve (first valve after sea chest, skin valve) leaking. Valve stem loose causing leakage. Class society surveyor to attest to permanent repairs.
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 12 May 2005
Resolution: Class report recieved. Report states the gasket has been seeled properly, no leakage were found.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 6 May 2005
Resolved
Lube oil vent on both port and starboard main deck need containment installed. Each containment should have a capacity of one barrel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 29 January 2007
Resolution: Containment has been installed on maindeck for both port and starboard lube oil vents.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 16 September 2004
Resolved
Marine Sanitation Device (Type II) tank is holed below the discgarge flange. Currently has wooden plug to prevent leak. Correct prior to departure. - 33 CFR 159
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 October 2004
Resolved 22 September 2004
Resolution: MSD Unalaska verified satisfactory repairs. -[name withheld]
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 16 September 2004
Resolved
Port lifeboat steering arrangements are not operational. Steering cable came free from drum. Correct prior to departure. -SOLAS 74/78 Ch.III Reg. 20.2
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2004
Resolved 22 September 2004
Resolution: MSD Unalaska cleared. Witnessed port lifeboat successfully maneuver while waterbourne. -[name withheld]
Lifesaving › Launching Appliances › Release Mechanism
Issued 16 September 2004
Resolved
Port lifeboat hook releasing mechanisms (forward and aft) are frozen. Cannot retrieve lifeboat after release. Correct priro to departure. -SOLAS 74/78 CH.III Reg. 20.2.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 September 2004
Resolved 22 September 2004
Resolution: MSD Unalaska cleared. Witnessed port lifeboat release (twice) with no problems. -[name withheld]
Engineering › Generator (propulsion-electric)
Issued 24 May 2003
Resolved
The rear engine oil seal on the no.3 generator is leaking and slinging oil onto the rear of the engine and motor. LEGACY COMPONENT DESC: Rear oil seal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 3 June 2003
Resolution: Received Class report attesting to satisfactory repairs to #3 generator.
Lifesaving
Issued 15 April 2001
Resolved
Only 1 of 4 required line throwing appliances onboard. Solas 74/78 Chap III Reg. 17.
Condition: Unknown
Due 31 August 2001
Resolved 20 July 2001
Navigation
Issued 15 April 2001
Resolved
No current Coast Guard light list onboard. 33 CFR 164.33
Condition: Unknown
Due 17 April 2001
Resolved 17 April 2001
Lifesaving
Issued 15 April 2001
Resolved
Lights on immersion suits had expired batteries. Solas 74/78 Chap. III Reg. 27.3
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Lifesaving
Issued 15 April 2001
Resolved
Quick release system for Lifebuoys would not operate. Solas 74/78 Chap. III Reg. 7.1_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Navigation
Issued 24 May 1994
Resolved
THE SUBJ VESSEL WAS MISSING CHARTS 11412, 11413 AND 11414 FOR ENTERING THE PORT OF TAMPA.
Condition: Unknown
Due 5 June 1994
Resolved 7 June 1994
Fire Fighting
Issued 24 May 1994
Resolved
The Subj Vessel's emergency fire pump was inoperable.
Condition: Unknown
Due 5 June 1994
Resolved 27 July 1994
Documentation
Issued 24 May 1994
Resolved
THE SUBJ VESSEL'S OIL TRANSFER PROCEDURES WERE MISSING THE FOLLOWING ITEMS:1) THE PROCEDURES FOR HANDLING MOORING LINES 2) PROCEDURES FOR OPERATING A MEANS OF COMMUNICATION AND 3) PROCEDURES FOR REPORTING DISCHARGES.
Condition: Unknown
Due 5 June 1994
Resolved 7 June 1994