Records from 1995 to 2007. Most recent: inspection, 5 March 2007.
Documentation record
Tonnage as PSIX records it205 - Convention (Subpart B), Net Ton
869 - Dead Weight, Ton
205 - Regulatory (Subpart C or D), Net Ton
696 - Convention (Subpart B), Gross Ton
696 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
5 March 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2882267
5 March 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2882270
27 May 2004
Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079636
5 March 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1492033
5 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 129633
Navigation › Piloting/Steering
Issued 7 March 2002
Resolved
No Tide and Current Tables publication on board for intended voyage area; SOLAS 74Am / V / 20; Provide same to satisfaction of attending USCG Marine Inspector. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2002
Resolved 21 March 2002
Resolution: USCG Marine Inspector attended vessel and observed proper Tide and Current Tables publication on board.
Pollution Prevention/Response › Prevention Equipment
Issued 7 March 2002
Resolved
Inoperable oily water separator (OWS) 15PPM sensor; MARPOL 73/78 Ax I/16(4); Repair and prove proper operation of OWS to satisfaction of IOPP certificate issuing authority. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2002
Resolved 21 March 2002
Resolution: New 15PPM sensor installed. Rcvd Class (ABS) report attesting to sat operation of 15PPM sensor.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 5 March 2002
Resolved
Excessive lube oil leakage from the front crankcase seal of the #1 ships's service generator; SOLAS 74Am / I / 11; Repair to satisfaction of Safety Construction Certificate issuing authority. LEGACY COMPONENT DESC: Crankcase
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 21 March 2002
Resolution: Rcvd Class report attesting to sat repair and operation of #1 generator.
Navigation › Piloting/Steering
Issued 5 March 2002
Resolved
No Light List publication on board for intended voyage area; SOLAS 74Am / V / 20; Provide same to satisfaction of attending USCG Marine Inspector. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 21 March 2002
Resolution: USCG Inspector attended vessel and observed proper light list on board.
Personnel › Certificates/Documents/Licenses
Issued 5 March 2002
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 21 March 2002
Resolution: USCG inspector attended vessel and observed valid 1st engineer''''''''s license.
Pollution Prevention/Response › Prevention Equipment
Issued 5 March 2002
Resolved
OWS discharge line has connection which bypasses the 15 ppm sensor; MARPOL Ax I/16(4); Provide survey by IOPP certificate issuing authority addressing bypass configuration and remove bypass as needed. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 21 March 2002
Resolution: Class deemed bypass needed to be removed. Bypass was removed. Class attested to sat configuaration and operation of OWS.
Documentation › Logs/Records
Issued 5 March 2002
Resolved
Improper Garbage Record Book; MARPOL Ax V/9(3); Provide same in accordance with cited regulation and make proper entries in same to satisfaction of attending USCG Marine Inspector. LEGACY COMPONENT DESC: Garbage Recordkeeping
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 21 March 2002
Resolution: USCG inspector attended vessel and observed proper Garbage record book w/proper entries.
Documentation › Manuals/Policy Documentation
Issued 5 March 2002
Resolved
No garbage Management Plan on board; MARPOL 73/78 Ax V/9(2); Provide same in accordance with cited regulation to satisfaction of attending USCG Marine Inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2002
Resolved 21 March 2002
Resolution: USCG inspector attended vessel and observed proper garbage management plan.