Records in 1995. Most recent: inspection, 9 November 1995.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Navigation
Issued 9 November 1995
Resolved
REPAIR RUDDER ANGLE INDICATOR. (INOPERABLE)
Condition: Unknown
Due 29 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 17 July 1995
Resolved
PROVIDE OIL RECORD BOOK PART 1.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Documentation
Issued 26 June 1995
Resolved
PROVIDE ONBOARD VESSEL VALID/STAMPED SHIPBOARD OIL POLLUTION EMERGENCY PLANPRIOR TO REENTRY TO ANY U.S. PORT.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Documentation
Issued 26 June 1995
Resolved
PROVIDE ONBOARD VESSEL VALID SAFETY CONSTRUCTION CERTIFICATE ISSUED BY FLAGADMINISTRATION PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA, FLORIDA.
Condition: Unknown
Due 26 June 1995
Resolved 27 June 1995
Documentation
Issued 26 June 1995
Resolved
PROVIDE ONBOARD VESSEL VALID INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE ISSUED BY FLAG ADMINISTRATION PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA,FLORIDA.
Condition: Unknown
Due 26 June 1995
Resolved 27 June 1995
Documentation
Issued 26 June 1995
Resolved
PROVIDE VALID SAFETY EQUIPMENT CERTIFICATE ON BOARD VESSEL ISSUED BY FLAG ADMINISTRATION PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA,FL.
Condition: Unknown
Due 26 June 1995
Resolved 27 June 1995
Documentation
Issued 26 June 1995
Resolved
PROVIDE ON BOARD VESSEL A VALID SAFETY RADIO TELEPHONE CERTIFICATE ISSUED BY THE FLAG ADMINISTRATION PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA, FLORIDA.
Condition: Unknown
Due 26 June 1995
Resolved 27 June 1995
Deck/Cargo
Issued 17 March 1995
Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE FWD AND AFT HYD CONTROL STATIONS. WOODEN BLOCKS IN THE CONTROLS.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Engineering
Issued 17 March 1995
Resolved
REMOVE OILY RESIDUE,FILM,BUILD UP FROM ENGINE ROOM DECKS,BLKHD,MACHINEY BILGES AND PIPING ETC.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 17 March 1995
Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE LEAK IN THE WHEEL HOUSE OVERHEAD ABOVE WHEEL, AND LIGHTS ON PORT SIDE.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Navigation
Issued 17 March 1995
Resolved
CORRECT DEFICIENCIES IN RUDDER ANGLE INDICATOR.
Condition: Unknown
Due 20 March 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 March 1995
Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE FWD GENERATOR, INOP.REINSTALL ANDPROPERLY MOUNT ALL F/O LINER IN COMPARTMENT CURRENTLY ANCHOR WINDLESS INOP.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Deck/Cargo
Issued 17 March 1995
Resolved
MAKE PROPER AND PERMENANT REPAIRS REPAIRS TO THE HYD UNIT WHICH OPERATE ANCHOR WINDLESS.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 17 March 1995
Resolved
MAKE PROPER AND PERMENANT REPAIRS TO ALL FLAMMABLE LIQUID LINES,VALVES FITTINGS, WHICH ARE CURRENTLY LEAKING DRIPPING OR SEEPING LIQUID.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Fire Fighting
Issued 10 January 1995
Resolved
Repair/renew and prove operation of ventilation fire dampers located on weatherdeck ventilators.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Deck/Cargo
Issued 10 January 1995
Resolved
Make permanent repairs to deteriorated hydraulic return/supply piping located on port side main deck in way of cargo holds. Temporary patches applied to piping in way of deteriorated piping.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Documentation
Issued 10 January 1995
Resolved
Provide on board vessel valid IOPP certificate issued by flag administration.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Accommodation/Occupational Safety
Issued 10 January 1995
Resolved
Means shall be provided for stopping ventilating fans serving machinery andcargo spaces. The means shall be capable of being operated from outside such spaces in case of fire.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Engineering
Issued 10 January 1995
Resolved
Fuel Oil transfer pumps, fuel oil units, pumps and other similar fuel pumpsshall be fitted with remote controls situated outside the space concerned._x001C_so that they may be stopped in the event of a fire arising in the space in which they are located.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 10 January 1995
Resolved
Provide up to date Fire Control plans which clearly depicts fire alarms, fire extinguishing appliances, means of access to different compartments, decks, ventilation systems including position of fire dampers and ventilation fans.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 10 January 1995
Resolved
Hot and cold fresh water shall be available in all communal wash places.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 10 January 1995
Resolved
All toilets shall be provided with ample flush water available at all _x001C_ times, That are independently controlled.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Accommodation/Occupational Safety
Issued 10 January 1995
Resolved
Provide on board approved Marine Sanitation Device.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995
Documentation
Issued 10 January 1995
Resolved
Provide current medical certificates for each crew member issued by flag administration.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Documentation
Issued 10 January 1995
Resolved
Provide oil transfer procedures.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Renew wasted deck plating in overhead of forward generator space. Deck is supporting the anchor windlass. Also opening allows water to enter compartment over generator unit which is covered with plastic.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Deck/Cargo
Issued 10 January 1995
Resolved
Renew containment for fuel oil tank fill starboard side._x001C_ Cite: 33 C.F.R. 155.320(b)
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Deck/Cargo
Issued 10 January 1995
Resolved
Install containment around all fuel oil/lube oil vents/fills on main deck.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 10 January 1995
Resolved
Liferaft container shall be marked with manufacturers serial number, name of approving authority, date when last serviced, length of painter, maximumpermitted height of stowage above waterline and launching instructions.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 10 January 1995
Resolved
Repair and prove operation of vent closures to galley located on aft bridgedeck.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Renew deteriorated vent closure for centerline cofferdam located on main deck centerline in way of aft cargo boom mast.
Condition: Unknown
Due 27 January 1995
Resolved 23 February 1995
Lifesaving
Issued 10 January 1995
Resolved
Provide two additional ring life buoys as per flag administration issued cargo safety equipment certificate.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 10 January 1995
Resolved
Provide waterlights to 50% of the required ring life buoys on board vessel as per cargo safety equipment certificate.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 10 January 1995
Resolved
Install retroreflective tape to all required ring life buoys.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 10 January 1995
Resolved
Provide ten life preservers with retroreflective material, whistle and lights.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Repair/renew inoperable/leaking fire hydrant on starboard side main deck just forward of deck house.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Renew broken valve handle to fire main hydrant valve located on starboard side in way of #2 cargo hatch/hold opening.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Navigation
Issued 10 January 1995
Resolved
Provide on board vessel current deviation table or compass comparison record.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 10 January 1995
Resolved
Every fuel oil suction pipe from a storage settling or daily service tank shall be fitted with a cock or valve capable of being closed from outside the space concerned in the event of a fire arising in the space in which such tanks are situated.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Accommodation/Occupational Safety
Issued 10 January 1995
Resolved
Install vent closure to forward generator space compartment vent located onmain deck forward.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Repair/renew watertight door leading to forward generator space to ensure watertight integrity.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
Provide valid Cargo Ship Safety Equipment certificate issued by flag administration.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Navigation
Issued 10 January 1995
Resolved
Provide on board vessel International Code of Signals.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Navigation
Issued 10 January 1995
Resolved
Provide and prove operation of an efficient daylight signalling lamp which shall not be solely dependent upon the ship's main source of electrical power.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 10 January 1995
Resolved
Install and prove operation of approved oily water separator.
Condition: Unknown
Due 20 January 1995
Resolved 23 January 1995
Documentation
Issued 10 January 1995
Resolved
Provide on board vessel a valid Cargo Ship Safety Construction certificate or it's equivalent.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Repair and prove operation of ballast pump.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Repair and prove operation of bilge pump.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Navigation
Issued 10 January 1995
Resolved
Provide on board vessel up to date list of lights, notices to mariners, tide tables and all other nautical publications necessary for vessel's intended voyage. _x001C_ CITE: 33 C.F.R. 164.33 all inclusive.
Condition: Unknown
Due 27 January 1995
Resolved 23 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Renew holed and deteriorated fire main piping on main deck in way of cargo hold.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
Vessel shall carry a qualified radiotelephone operator.
Condition: Unknown
Due 20 January 1995
Resolved 23 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Repair and prove operation of fire pump.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 10 January 1995
Resolved
Repair fuel oil and lube oil leaks on forward generator._x001C_ Fuel oil and lube oil leaks drain directly into bilge.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Clean bilges in forward generator compartment of oil residues.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Provide and install closure device for #2 and #5 port and #5 starboard ballast tank vent. (conical plugs)
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Renew damaged closure bolt to cargo hold hatch cover located on the main deck centerline in way of aft cargo boom mast.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Provide 6 bolts of correct length and diameter for standard discharge connection. Cite: 33 C.F.R. 155.430(a)(6)
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 10 January 1995
Resolved
Perform fire and abondon ship drill to the satisfaction of the attending U.S. Coast Guard Marine Inspector prior to departure from the Port of Pensacola Florida.
Condition: Unknown
Due 27 January 1995
Resolved 23 February 1995
Unknown
Issued 10 January 1995
Resolved
Provide closure for fresh water vent on port side aft main deck.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Unknown
Issued 10 January 1995
Resolved
Provide securing device for vent closure to starboard side steering compartment vent.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 10 January 1995
Resolved
Provide closure for starboard side main deck aft slop tank vent.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Electrical
Issued 10 January 1995
Resolved
Provide a means to illuminate the stowage position of the liferaft from emergency power source.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
Provide oil record book.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Lifesaving
Issued 10 January 1995
Resolved
Provide on board a line throwing appliance to the satisfaction of flag administration.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Provide on board firemans outfit to the satisfaction of flag administration.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
Provide and post muster list and emergency procedures of special duties to be undertaken in the event of an emergency on board vessel.
Condition: Unknown
Due 20 January 1995
Resolved 27 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Install missing damper to starboard ventilator located on aft bridge deck.
Condition: Unknown
Due 20 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Make permanent repairs to damaged section of stem. Bulkhead stiffners and brackets in way of stem are missing. Temporary repairs have been started but not completed.
Condition: Unknown
Due 26 January 1995
Resolved 2 March 1995
Documentation
Issued 10 January 1995
Resolved
Conduct survey of vessel for compliance of SOLAS Chapter IV and issue exemption certificates in any area of non-compliance.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Provide a fire hose, spanner wrench, and fire nozzle to each fire station throughout vessel.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Fire Fighting
Issued 10 January 1995
Resolved
Conduct hydrostatic test of all fire hoses in the presence of a Coast GuardMarine inspector prior to departing Port of Pensacola, Fl.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
Provide on board vessel exemption certificate issued by flag administrationfor lifesaving equipment exemptions with conditions and duration exemption is granted.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Engineering
Issued 10 January 1995
Resolved
Prove operation of main diesel engine.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Electrical
Issued 10 January 1995
Resolved
Repair and prove operation of starting air compressor.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Renew holed bilge piping located on port side of engine room in way of oilywater seperator in overhead.
Condition: Unknown
Due 27 January 1995
Resolved 27 January 1995
Documentation
Issued 10 January 1995
Resolved
Comply with requirements of MSO Mobile Captain of the Port Order prior to departure from the Port of Pensacola, Fl.
Condition: Unknown
Due 27 January 1995
Resolved 23 February 1995
Construction/Loadline
Issued 10 January 1995
Resolved
Renew deteriorated/wasted deck plating located in engine room overhead above oily water seperator and air compresser.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Electrical
Issued 10 January 1995
Resolved
Install adequate battery trays for each battery installation to prevent shifting of batteries and containment for accidental release of battery electrolite.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Electrical
Issued 10 January 1995
Resolved
Repair and prove operation of #3 generator.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Electrical
Issued 10 January 1995
Resolved
All places on board vessel where people have to work or pass shall be adequately lighted and ventilated. Noted numerous light fixtures throughout vessel that were extinguished.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Electrical
Issued 10 January 1995
Resolved
Electrical equipment should be protected and maintained to prevent danger to people on board vessel. Noted numerous exposed wires/open electrical boxes throughout vessel, especially in the machinery spaces.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Lifesaving
Issued 10 January 1995
Resolved
Install guards or fencing around rotating and hot parts of machinery and equipment to prevent injury to personnel.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Engineering
Issued 10 January 1995
Resolved
Install vent closure/flame screen to forward generator fuel oil day tank vent on main deck forward.
Condition: Unknown
Due 27 March 1995
Resolved 27 March 1995