CAPT MICHAEL

CAPT MICHAEL is a 1994 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1994, most recently in August 2025, along with 160 deficiencies, 3 operational controls and 2 casualty investigations between 2008 and 2011.

Records from 1994 to 2025. Most recent: inspection, 5 August 2025.

Built
1994
Last inspected
5 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8073
400813
Flag
UNITED STATES
367010370
Maury page id
psix-400813

Inspections, by type

…with no type recorded5
Years with a record 29 calendar years (1994–2025)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.5 ft × 19.8 ft × 7.2 ft
Registered tonnagegross 55 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJAMES C DYE · KEY WEST, FL, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portISLAMORADA, FL
Trade endorsementsFishery
DocumentationValid · issued 15 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Simplified, Net Ton
55 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8073MMSI 367010370 · active · compulsorily equipped · granted 9 January 2025, expires 23 January 2035
WDC3570MMSI 367010370 · terminated · compulsorily equipped · granted 12 January 2005, cancelled 22 January 2015
WCJ6203MMSI not assigned · expired · compulsorily equipped · granted 13 July 1994, cancelled 26 September 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

5 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8194561
10 September 2024 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7999841
19 August 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7984644
8 May 2023 In-Service Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7683802
20 October 2022 In-Service Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7580781
20 September 2022 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7562184
14 September 2022 DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7558552
4 November 2021 Deficiency Check · Examination of Repairs · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7345517
21 April 2021 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7179931
21 December 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7114794
11 September 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7057625
5 August 2020 DAPI Audit · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7024976
6 November 2019 Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6850816
17 April 2019 Administrative Inspection · Simplified Stability Test · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6663035
6 September 2018 DAPI Audit · Annual Survey · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661228
28 November 2017 DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6554310
18 October 2017 Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6290171
1 June 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5882135
7 October 2015 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5728433
11 August 2015 COI Inspection · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5208559
21 September 2011 Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4181144
20 February 2010 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3684129
8 March 2009 Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 3454583
5 December 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3377642
25 October 2008 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3356546
3 January 2008 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3127971
28 November 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3104609
18 September 2007 Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3060745
19 January 2007 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2858456
22 February 2006 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2590077
28 September 2005 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2503156
19 August 2005 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2466121
15 November 2004 Deficiency Check · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2232460
24 February 2004 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2012052
6 November 2003 Deficiency Check · Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1932129
18 September 2003 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1907581
6 November 2002 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1698951
20 November 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1449538
25 September 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1373630
12 October 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 823390
10 October 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384583
24 August 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384537
2 November 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 797342
2 September 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458678
31 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1119790
20 October 1998 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461085
31 August 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 796809
19 November 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1108052
27 August 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1120681
13 November 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174023
8 November 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 864109
8 October 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 838529
17 September 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1139468
23 April 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1080686
20 February 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882040
17 October 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184463
10 October 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877438
7 October 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1079288
6 January 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174156
2 December 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1179885
25 November 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 865496
13 September 1994 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 868803
19 August 1994 Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1438212

Deficiency record · 160

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2025 Resolved
Life Jacket donning placard is missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2025
Resolved 14 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 August 2025 Resolved
Renew retro tape on life floats with proper SOLAS tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2025
Resolved 14 August 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 August 2025 Resolved
Repair/replace stern light it's INOP.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2025
Resolved 14 August 2025
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 August 2025 Resolved
Port side fuel shut off valve needs to be labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2025
Resolved 14 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 August 2025 Resolved
Replace/repair fire nozzle. Fire nozzle only has straight stream and is not a working vary nozzle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2025
Resolved 14 August 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 September 2022 Resolved
Nav Chart on GPS is not updated with the latest version. Vessel must have updated Nav charts onboard. Either update Nav chart on GPS or buy CG approved paper Nav Chart
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 20 October 2022
Resolution: Updated GPS with latest version of NAV Charts IAW NVIC 01-16
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 September 2022 Resolved
Guards over rotating machinery on front of each MDE is missing. Must have guards over all rotation machinery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 28 November 2022
Resolution: Installed all the guards
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 September 2022 Resolved
Stern light is not working. Make repairs and test to the satisfaction of attending CG Marine Inspector. Vessel restricted to daylight hours only until fixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 28 November 2022
Resolution: Replaced stern light
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2022 Resolved
FWD life float is faded. Must repaint forward life float.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 20 October 2022
Resolution: Life float was repainted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2021 Resolved
Port MDE failed causing damage to #1 & #6 cylinder. After repower, must conduct engine alarm testing and sea trials prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2022
Resolution: Conducted alarm test and satisfactory sea trials.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 November 2021 Resolved
FCC Safety Certificate expired back in 2019. Must renew FCC Safety Certificate. 47 CFR 13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 January 2022
Resolution: New FCC certificate was issued to vessel
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 November 2021 Resolved
First aid kit was found with several missing/expired items. Must replace missing/expired items to meet requirements in 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 22 November 2021
Resolution: Received all items while out conducting drills. All SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 November 2021 Resolved
Vessel did not have any logs showing monthly EPRIB test or monthly survival craft maintenance/inspection. Must have test EPRIB and inspect all survival craft monthly and log it.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 January 2022
Resolution: Showed logs with montly test/inspections
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 November 2021 Resolved
Vessel could not provide proof of crew traing logs required for all new higher's. Must make and provide training logs for each crew member
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 22 November 2021
Resolution: Training logs were found in office and sent to CG later in the afternoon.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 22 November 2021 Resolved
Vessel is missing the Emergency Broadcast placard. Must replace missing placard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 January 2022
Resolution: Replaced missing VHF Emergency Broadcast placard
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 November 2021 Resolved
Vessel does not have a CG approved paper NAV Chart onboard. Vessel's GPS is not updated with latest software/charts to meet requirements in NVIC 01-16 instead of paper chart. Must update GPS with latest software/chart
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 January 2022
Resolution: Updated GPS electronic charts to meet requirements of NVIC 01-16
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 November 2021 Resolved
Bottom life float was found worn/faded. Must repaint life float and replace worn/faded retro with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 24 January 2022
Resolution: Repainted and added all new retro tape
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 November 2021 Resolved
Vessel failed to have annual inspection within 3 months before or after anniversary date of issuance of Certificate of Inspection. Vessel must conduct annual inspection and complete any repairs to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 November 2021
Resolved 22 November 2021
Resolution: Conducted annual inspection
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 April 2021 Resolved
Grind and renew 02 areas on the outer hull below the paint stripe as marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 April 2021 Resolved
Grind and renew 03 areas on the outer hull above the paint stripe as marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 April 2021 Resolved
Grind and renew 02 areas on the main deck near the starboard embarkation area as marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 April 2021 Resolved
Vessel must maintain a permanent 6" coaming around the main deck house. Permanently fill 04 limber holes as marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 21 April 2021 Resolved
Fill in and make watertight the hydraulic line penetration hole in the collision bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 April 2021 Resolved
Make the sea valves for the fire main suction and generator raw water cooling available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 April 2021 Resolved
The port engine's raw water cooling sea valve is seized. Prove proper operation or renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2021 Resolved
The manifolded bilge piping in the lazarette is not secured in place. Properly secure pipe.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2021 Resolved
Port and starboard lower cutlass bearings are worn from fishing line/hooks wrapped around the shaft. Replace or remove and make available for full inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020 Resolved
Replace 07 adult life jackets and mark vessels name and passenger count is reduced by 07.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2020
Resolved 11 September 2020
Resolution: Bought 10 new life jackets and marked with vessels name
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 August 2020 Resolved
Repaint and renew reflective tape on bottom two life rafts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 11 September 2020
Resolution: Repainted and added new reflective tape
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 August 2020 Resolved
Update Garmin chart with latest edition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
Resolution: downloaded all current NAV pubs to all crews phones
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 August 2020 Resolved
Correct EPIRB registration with correct call sign.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 11 September 2020
Resolution: New EPIRB registration with all correct info as required
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 August 2020 Resolved
Provide alcohol test for crew.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 11 September 2020
Resolution: New alcohol swaps with experation of May 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 5 August 2020 Resolved
Renew or replace deck inspection cover prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2020
Resolution: Deck inspection cover was purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 November 2019 Resolved
Vessel is waiting for a new life float. Current float capacity is not enough for 125 passengers. Vessel is restricted to not more than 118 total persons on board until new float arrives.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 January 2020
Resolution: New 22 person life float arrived and properly stowed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 November 2019 Resolved
Renew/replace grab line on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2020
Resolution: New grab lines were spliced onto the old life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2019 Resolved
14 adult life jackets are wasted. No more than 91 people on board until corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: Inspector verified that 115 adult PFD’s and 13 child PFD’s were on board and serviceable.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 November 2019 Resolved
Start logs for EPIRB, survival craft maintenance, fire drill, and MOB drill.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: Logs were started with correct log entries.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 November 2019 Resolved
Need to have light list and tide table on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2020
Resolution: Light list and tide tables have been updated and placed on board.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 November 2019 Resolved
Replace fire hose with proper hose and/or equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2020
Resolution: Fire nozzle and hose hardware was cleaned to provide sufficient firefighting pressure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 November 2019 Resolved
Repair forward hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2020
Resolution: Repaired forward hatch with proper maintenance.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 April 2019 Resolved
Repair fiberglass shaft log on portside, repair shall be made following the original layup schedule.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: STBD shaft log repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 April 2019 Resolved
Grind down fiber glass on areas identified by attending Marine Inspectors and make available for re-inspection: 6 spots on outside hull, stringer in forward compartment just aft of collision bulkhead, port exhaust muffler.
Action required: 705 - Other - as specified
Resolved 6 May 2019
Resolution: Hull areas repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2019 Resolved
Replace cutlass bearings on both struts for each shaft.
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: All cutlass bearings replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2019 Resolved
Provide a metallic positive shutoff valve at the hull penetration for each installed submersible bilge pump.
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: All over board discharges shutoffs for submersible bilge pumps have been replaced with metallic valves.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2019 Resolved
Remove all sections of non metallic flexible hose for the wet exhaust systems and clean entire system, make available for re-inspection. Heavy deposits of carbon was discovered in exhaust by way of rear engine room bulkhead penetration.
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: All flexible exhaust hoses replaced and FRP sections cleaned.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2019 Resolved
Attach submersible bilge pump to hull in forward compartment.
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: Pump attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2019 Resolved
Make penetrations in collision bulkhead watertight, limber holes located in lower keel of bulkhead.
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: Holes sealed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 17 April 2019 Resolved
Coaming shall be of at-least 6inches high operating on an partially protected route, 02 holes drilled in aft deckhouse coaming.
Action required: 705 - Other - as specified
Resolved 13 December 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 April 2019 Resolved
Grind down to good deck material on 02 soft spots near bow, make avialable for re-inspection.
Action required: 705 - Other - as specified
Resolved 13 December 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2019 Resolved
Cap overboard penetration in compartment forward of engine room. 2 inch diameter hose is not connected to any draining arrangement.
Action required: 705 - Other - as specified
Resolved 13 December 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 April 2019 Resolved
Repair/replace identified deck rail stanchions on upper and lower deck.
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: Stanchions repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 April 2019 Resolved
Demonstrate proper operation of deck hatch securing devices.
Action required: 705 - Other - as specified
Resolved 13 December 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2019 Resolved
Make forward compartment that houses vessel battery chargers water tight, identified deck penetrations that are allowing ingress of water.
Action required: 705 - Other - as specified
Resolved 13 December 2019
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 17 April 2019 Resolved
Conduct simplified stability test in the presence of a Marine Inspector. Vessel has significantly reduced in weight due to repowering main propulsion.
Action required: 705 - Other - as specified
Resolved 7 August 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2019 Resolved
Make all thru-hull valves available for re-inspection after replacement. Valves below the waterline and with-in 6 inches of waterline.
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: All thru hull fittings replaced and verified operational.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 September 2018 Resolved
Provide VHF radio that will accept GPS input, and input MMSI#.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2018
Resolution: Installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2018 Resolved
Repaired a main pin on steering ram.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2018
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 September 2018 Resolved
Provide a means to operate remote fuel valves from outside the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2018
Resolution: Installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2018 Resolved
Install painter line in the correct basket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2018
Resolution: Installed
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 November 2017 Resolved
Life floats are all in disrepair, and will need new paint, and repairs.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New Life floats were provided and placed into service.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 November 2017 Resolved
FWD compartment bilge alarm light is extinguished, renew/repair.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New lights were installed and tested. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 November 2017 Resolved
4 adult and 4 child sized life jackets are wasted and must be renewed, prior to carrying more than 98 passengers.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New life jackets were provided and marked.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 28 November 2017 Resolved
Radar is inoperable. Renew/repair.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: A new radar was installed and tested. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 November 2017 Resolved
Light list and tide tables are out of date and must be renewed.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New publications were provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 November 2017 Resolved
Anchor light is not of an approved type and must be replaced with an approved light and fixture.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New approved PERKO light was installed and tested. All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 November 2017 Resolved
Captain does not have an approved FCC operators permit.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: Captain completed required FCC course, and recieved operators permit.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 November 2017 Resolved
First aid kit has expired and missing contents, renew contents, or renew kit.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New approved first aid kit was provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 November 2017 Resolved
Fuel tanks are not grounded from the fill pipe to the tank. run new grounding strap from the fill pipe to the fuel tank.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New grounding wire was properly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 November 2017 Resolved
Generator does not have a gage to measure frequency. Provide.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New gage was installed at the operators station, and was tested. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 November 2017 Resolved
Vessel is missing 2 of the 3 required fire buckets. Provide.
Action required: 10 - Deficiency Rectified
Resolved 13 December 2017
Resolution: New fire buckets were provided.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 October 2017 Resolved
Make all watertight bulkheads watertight. Multiple bulkhead penetrations.
Action required: 705 - Other - as specified
Resolved 27 October 2017
Resolution: Sealed all penetrations.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 18 October 2017 Resolved
Replace fixed fire extinguishing cylinder in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2019
Resolution: system replaced prior to this date, but was not reflected in MISLE
Construction/Loadline › Structures › Scuttle
Issued 18 October 2017 Resolved
Make watertight hatch to steering compartment watertight.
Action required: 705 - Other - as specified
Resolved 27 October 2017
Resolution: Resealed hatch frame to deck.
Construction/Loadline › Hull › Stringer
Issued 18 October 2017 Resolved
Grindout cracks in #1 hold port and starboard stringers.
Action required: 705 - Other - as specified
Resolved 27 October 2017
Resolution: Cracks were ground out and made available for inspection.
Engineering › Fuel Oil Service System › Suction Strainer
Issued 18 October 2017 Resolved
Renew fuel stainers with maine grade strainers.
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 27 October 2017
Resolution: Strainers were renewed with marine grade strainers.
Construction/Loadline › Hull › Hull Plating
Issued 18 October 2017 Resolved
Make repairs to identified areas on bow pulpit.
Action required: 705 - Other - as specified
Resolved 22 November 2017
Resolution: Repaired identified areas.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 September 2011 Resolved
Renew wasted electrical box in forward tank compartment, also remove unused wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 21 October 2011
Resolution: New box properly installed, all unused wire was removed.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 September 2011 Resolved
Forward and aft deck hatches are corroded and have torn gaskets, do not operate properly. Renew gaskets and perform maintenance on both hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 21 October 2011
Resolution: Hatches properly serviced and in proper operating condition.
Stability › Watertight Integrity › General
Issued 21 September 2011 Resolved
Seal all holes in bulkhead between forward compartment and engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 21 October 2011
Resolution: All holes properly sealed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 September 2011 Resolved
Replace non-approved exhaust hose on starboard side in aft compartment with approved marine exhaust hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 21 October 2011
Resolution: New marine exhaust hose properly installed.
Stability › Watertight Integrity › General
Issued 21 September 2011 Resolved
Repair cracks where both exhaust pipes penetrate through hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2011
Resolved 21 October 2011
Resolution: Cracked fiberglass at exhaust pipe penetrations properly repaired.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 December 2008 Resolved
Conduct annual inspection IAW 46 CFR 176.500.
Due 5 December 2008
Resolved 5 December 2008
Documentation › Certificates/Documents › FCC SSL
Issued 28 November 2007 Resolved
Prove availability of vessel's Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 3 January 2008
Communications › Alarms/Indicators › High Water Alarm
Issued 28 November 2007 Resolved
Prove proper operation of visual indicator for forward high water level bilge alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 December 2007
Resolved 29 November 2007
Communications › Radio Communications › EPIRB
Issued 28 November 2007 Resolved
Provide new EPIRB antenna. Vessel restricted to 3nm.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 29 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 November 2007 Resolved
Provide proper operating starboard and port running lights. Vessel restricted to day time operations only.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 29 November 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 28 November 2007 Resolved
Provide grabline for upper deck ring lfebouy.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 29 November 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 28 November 2007 Resolved
Cover opening in junction box located in forward area of engine space.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 29 November 2007
Engineering › Steering Gear System › Rudder Stock
Issued 28 November 2007 Resolved
Minimize water leakage located in starboard side rudder post.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 29 November 2007
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 November 2007 Resolved
Prove availability of vessel's certificate of documentation.
Action required: 705 - Other - as specified
Due 28 December 2007
Resolved 3 January 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 August 2005 Resolved
Provide an up to date U.S Coast Pilot.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 22 February 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 August 2005 Resolved
Provide up to date Tide/Tidal Current Tables.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 22 February 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 August 2005 Resolved
Replace broken starboard running light.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 28 September 2005
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 19 August 2005 Resolved
Replace cracked starboard side window in pilothouse.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 22 February 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 August 2005 Resolved
Post Emergency broadcast placard near operating station.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 28 September 2005
Lifesaving › Hand Flares › Not on Board
Issued 19 August 2005 Resolved
Provide three(3) orange day smoke flares.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 19 August 2005
Resolution: Vsl rep. provided three (3) Hand red distress signals approval # 160.021 as a substitute for three(3) hand orange smoke flares IAW 46 CFR 180.68(c)(2)(ii).
Engineering › Fuel Oil Service System › Valve
Issued 19 August 2005 Resolved
Lable both emergency fuel oil shut-off valves.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 19 August 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 August 2005 Resolved
Provide and install machinery guards on both Main Diesel Engines.
Action required: 705 - Other - as specified
Due 19 September 2005
Resolved 22 February 2006
Documentation › Certificates/Documents › FCC SSL
Issued 15 November 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 November 2004 Resolved
Provide 2 additional adult size PFD's.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Lifesaving › Lifefloat › Serviceable
Issued 15 November 2004 Resolved
Patch surface cracks on all 3 Lifefloats and re-paint using manufacturer's approved materials.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Lifesaving › Lifefloat › Painter
Issued 15 November 2004 Resolved
Renew painters on all 3 Lifefloats.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 15 November 2004 Resolved
Renew corroded hydraulic hose on starboard side of steering ram.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Engineering › Fuel Oil Service System › Valve
Issued 15 November 2004 Resolved
Repair emergency fuel shut-offs.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 15 November 2004 Resolved
Service fixed fire suppression system in the engineroom.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 15 November 2004 Resolved
Tighten port shaft packing.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Engineering › Bilge Water Management System › Hose
Issued 15 November 2004 Resolved
Provide additional hoses for portable bilge pump.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Engineering › Bilge Water Management System › Pump
Issued 15 November 2004 Resolved
Repair pump for fixed bilge pumping system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2004
Resolved 3 December 2004
Resolution: Completed.
Communications › Radio Communications › EPIRB
Issued 6 November 2003 Resolved
Renew hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 19 December 2003
Resolution: Corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 November 2003 Resolved
Repair indicator lights for bilge high level alarms in #1 & #2 compartments.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 19 December 2003
Resolution: Corrected.
Communications › Audible Communications › SPD (Other)
Issued 6 November 2003 Resolved
Provide a battery powered bullhorn IAW 46 CFR 184.610.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 19 December 2003
Resolution: Corrected.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 November 2003 Resolved
Provide updated light list, tide tables & tidal current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 November 2003
Resolved 19 December 2003
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 November 2003 Resolved
Modify deck rails so that space between rail courses does not exceed 4 inches. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 6 February 2004
Resolved 24 February 2004
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 6 November 2002 Resolved
Provide 32 additional adult-sized PFDs. Vessel is limited to not more than 73 total persons until corrected.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Engineering › Bilge Water Management System › Pump
Issued 6 November 2002 Resolved
Demonstrate proper operation of fixed bilge pumping system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 November 2002 Resolved
Repair stern light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 6 November 2002 Resolved
Renew battery and hydrostatic release on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 6 November 2002 Resolved
Provide proof of registration for vessel's EPIRB.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 6 November 2002 Resolved
Perform annual servicing on Fixed Fire Extinguishing system. LEGACY COMPONENT DESC: Annual Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing
Issued 6 November 2002 Resolved
Provide proof of a valid drug testing program. LEGACY COMPONENT DESC: Program
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 6 November 2002 Resolved
Repair surface cracks on life floats using manufacturer's approved patch kit and restencil vessel's name and capacity. LEGACY COMPONENT DESC: Life Float outer covering
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2002
Resolved 8 November 2002
Resolution: Corrected
Lifesaving
Issued 25 September 2001 Resolved
Provide 30 additional adult PFD's. Vessel is limited to not more than 75 total persons until completed.
Condition: Unknown
Due 20 January 2002
Resolved 6 November 2002
Resolution: Cleared and re-issued as "Provide 32 additional adult-sized PFDs. Vessel is limited to not more than 73 total persons until corrected.
Engineering
Issued 24 August 2000 Resolved
Provide guards over the flywheels on both M/Es._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Documentation
Issued 24 August 2000 Resolved
Provide a vessel logbook with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Navigation
Issued 24 August 2000 Resolved
Repair the running lights._x001C_ _x001C_ The vessel is restricted to daylight operations until this item is corrected._x001C_
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Documentation
Issued 24 August 2000 Resolved
Provide a current FCC Operators permit._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Lifesaving
Issued 24 August 2000 Resolved
Repair/replace 23 adult and 1 child PFD._x001C_ _x001C_ Passengers are reduced to 85 adults until this item is corrected._x001C_ _x001C_
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Lifesaving
Issued 24 August 2000 Resolved
Replace the hydrostatic release on the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Fire Fighting
Issued 2 September 1999 Resolved
Have all fixed fire extinguishing systems serviced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Navigation
Issued 2 September 1999 Resolved
Make permanent repairs to starboard rudder packing gland._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1999
Resolved 15 September 1999
Lifesaving
Issued 2 September 1999 Resolved
Affix new retro-reflective tape on all L/Fs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 2 September 1999 Resolved
Update emergency check-off list._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 2 September 1999 Resolved
Affix new retro-reflective tape on all PFDs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Fire Fighting
Issued 2 September 1999 Resolved
Install a manual activation switch for the fixed fire extinguishing system in the engine room._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Engineering
Issued 2 September 1999 Resolved
Repair fuel filter to M/E._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 September 1999
Resolved 2 September 1999
Lifesaving
Issued 31 August 1998 Resolved
Renew retro-reflective tape and replace paddles on all LFs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Lifesaving
Issued 31 August 1998 Resolved
Renew retro-reflective tape on all PFDs._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Documentation
Issued 31 August 1998 Resolved
Provide a vessel log book with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 August 1998
Resolved 31 August 1998
Lifesaving
Issued 27 August 1997 Resolved
Provide a ladder to retreive a person from the water in case of a person overboard._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 27 August 1997
Lifesaving
Issued 27 August 1997 Resolved
Provide an EPIRB. The vessel is restricted to no more than 3 miles from shore until an EPIRB is mounted on the vessel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 3 September 1997
Accommodation/Occupational Safety
Issued 27 August 1997 Resolved
Provide a sign on/near ladder to upper deck with number of passengers allowed on the upper deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 September 1997
Resolved 3 September 1997
Navigation
Issued 27 August 1997 Resolved
Repair/replace loose bolts and tighten packing on the steering system._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1997
Resolved 3 September 1997
Documentation
Issued 8 October 1996 Resolved
Provide evidence of a company drug and alcohol testing policy.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Documentation
Issued 8 October 1996 Resolved
Provide evidence of a valid FCC Radio Telephony Satety Certificate.
Condition: Unknown
Due 8 November 1996
Resolved 8 November 1996
Electrical
Issued 8 October 1996 Resolved
Install an ammeter on the ships service generator.
Condition: Unknown
Due 8 November 1996
Resolved 9 November 1996
Lifesaving
Issued 8 October 1996 Resolved
Place Retro-Reflective material on ring life buoy.
Condition: Unknown
Due 8 November 1996
Resolved 9 November 1996
Documentation
Issued 8 October 1996 Resolved
Post stability letter in wheelhouse.
Condition: Unknown
Due 8 November 1996
Resolved 9 November 1996
Accommodation/Occupational Safety
Issued 10 October 1995 Resolved
Replace broken glass in: 1. Wheelhouse port aft._x001C_ 2. Main cabin aft door._x001C_ 3. Port head window.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Documentation
Issued 10 October 1995 Resolved
Provide evidence of compliance with CG letter dated 30 AUG 95 addressing _x001C_ questions resulting from the vessels plan review.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Documentation
Issued 10 October 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Electrical
Issued 10 October 1995 Resolved
Demonstrate operation of S/S generator and all meters and gauges._x001C_ (New hertz gauge being installed)
Condition: Unknown
Due 17 October 1995
Resolved 25 October 1995
Lifesaving
Issued 10 October 1995 Resolved
Stencil paddles on lifefloat with vessel name.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Electrical
Issued 25 November 1994 Resolved
Install a frequency meter for Ships Service generator as required by_x001C_ 46 CFR 183.10-5(g). Meter to be installed in wheelhouse per discussion andagreement with local inspector.
Condition: Unknown
Due 15 December 1994
Resolved 3 December 1994
Documentation
Issued 13 September 1994 Resolved
Provide valid FCC Radiotelephony Certificate.
Condition: Unknown
Due 20 September 1994
Resolved 20 September 1994
Accommodation/Occupational Safety
Issued 13 September 1994 Resolved
Install a ladder in the forepeak.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Fire Fighting
Issued 13 September 1994 Resolved
Replace 2 B-I extinguishers with 2 B-II extinguishers.
Condition: Unknown
Due 3 October 1994
Resolved 15 September 1994
Lifesaving
Issued 13 September 1994 Resolved
Install latch on lifejacket locker to prevent it from lifting in a wind.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Lifesaving
Issued 13 September 1994 Resolved
Install two four foot paddles on each lifefloat.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Lifesaving
Issued 13 September 1994 Resolved
Seperate child and adult lifejackets by using a partition in the present locker OR stow them in a different locker.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Documentation
Issued 13 September 1994 Resolved
Submit as-built electrical plan for review.
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994

Casualty record · 2

25 October 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3356546
14 May 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4233294
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.