Records from 1994 to 2024. Most recent: inspection, 26 January 2024.
Inspection history · 39
26 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856160
20 March 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1759940
20 March 2003
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1760351
6 February 2003
Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1740838
10 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1728865
9 January 2003
Passenger/Freight Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1728244
21 August 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 13636
24 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 30938
29 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 283137
27 August 2000
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1053214
28 May 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 279311
28 May 2000
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818951
27 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275825
27 February 2000
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818316
23 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768075
28 January 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 210260
16 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79399
28 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 435787
28 November 1999
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046746
22 October 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 792381
12 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432806
12 September 1999
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 785419
6 June 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 429423
6 June 1999
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 806260
28 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426090
28 February 1999
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 798618
4 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 443927
29 November 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 423285
29 November 1998
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 805492
30 October 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 422248
30 October 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 803617
4 September 1998
Quarterly Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 802728
4 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 418610
4 June 1998
Quarterly Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1458542
3 June 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417929
3 June 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 794662
2 February 1998
Administrative
Administrative · Marine Safety Center (MSC) · Activity 1106324
1 December 1997
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1458477
25 February 1994
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1165631
Documentation › Certificates/Documents
Issued 20 March 2003
Resolved
Provide updated Passenger Ship Safety Certificate to include updated number of passengers and liferafts. Prior to issuance of COC. LEGACY COMPONENT DESC: Passenger Ship Safety Certificate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Documentation › Certificates/Documents
Issued 20 March 2003
Resolved
Provide evidence of required STCW trainings for all crew, including hotel staff. Specially, section A-V/3 of the code. Prior to issuance of COC. LEGACY COMPONENT DESC: STCW Trainings
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 March 2003
Resolved
Make permanent repairs to sewage line coming off the #1 sewage pump in the stabilizer room, has several soft patches.
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 20 March 2003
Resolved
Make permanent repairs to sewage drain line in the overhead in the stabilizer room, has a soft patch on the elbow near bulkhead.
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Engineering
Issued 20 March 2003
Resolved
Install gasket on flange on gas oil line on port side in the stabilizer room.
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Pollution Prevention/Response › Prevention Equipment
Issued 20 March 2003
Resolved
Have class address doublers on the port and starboard MSD holding tanks in the stabilizer room. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Due 20 March 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Construction/Loadline
Issued 20 March 2003
Resolved
Have class address wasted bulkhead in void space (former laundry storage space) forward of the laundry room.
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Lifesaving › Launching Appliances › Falls
Issued 20 March 2003
Resolved
Provide documentation showing when lifeboat davit falls were last replaced. Prior to issuance of COC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Engineering
Issued 20 March 2003
Resolved
Repair leaking oil line in engine room, bottom deck, port side of main diesel engine.
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Engineering
Issued 20 March 2003
Resolved
Have class address wasted and severed pipe in overhead on starboard side above boiler.
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Pollution Prevention/Response › Prevention Equipment
Issued 20 March 2003
Resolved
Make permanent repair to oil discharge line to shore on starboard side of main engine room. Line has soft patch. LEGACY COMPONENT DESC: Oil discharge line
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Pollution Prevention/Response › Prevention Equipment
Issued 20 March 2003
Resolved
Make permanent repairs to sewage line on starboard side of main engine room, line has soft patch. LEGACY COMPONENT DESC: Sewage lines
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Lifesaving
Issued 20 March 2003
Resolved
Provide exit signage for galley area.
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Lifesaving
Issued 20 March 2003
Resolved
Prove low location lights meet functional reqirements. Prior to issuance of COC. LEGACY COMPONENT DESC: Location lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Documentation
Issued 20 March 2003
Resolved
Provide list of cabins that will be occupied by passengers during the voyage. Prior to issuance of COC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Operations/Management
Issued 20 March 2003
Resolved
Remove wood furniture from passenger cabins 1018-1036 or demonstrate that boundaries meet requirements for category 7 spaces or provide temporary proposal for equivalent protection. Prior to issuance of COC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2024
Resolution: 26JAN2024: Due to age of open deficiencies , vessel statues had been changed to inactive, Vessel has not come back to the U.S since last activity with 16 open def's in 2003. I cleared deficiency from activity (Act #1760351)to clean up Sector Miami Open D
Fire Fighting
Issued 28 November 1999
Resolved
PERMENANTLY REPAIR PIPING FROM THE EMERGENCY FIRE PUMP TO THE EDUCTOR IN BOW THRUSTER ROOM.
Condition: Unknown
Due 28 February 2000
Resolved 27 December 1999
Lifesaving
Issued 28 November 1999
Resolved
REPLACE RETRO-REFLECTIVE TAPE IN STAIR WELLS.
Condition: Unknown
Due 28 December 1999
Resolved 27 December 1999
Unknown
Issued 28 November 1999
Resolved
REPAIR AIR LEAKS ON STARTING AIR COMPRESSOR CYLINDER HEADS.
Condition: Unknown
Due 28 February 2000
Resolved 27 December 1999
Accommodation/Occupational Safety
Issued 28 November 1999
Resolved
ADDRESS WITH RECOMMENDATIONS FOR MISSING DOOR, DOOR CLOSURE, LIGHT COVERS AND CEILING PANELS IN PHOTO LAB.
Condition: Unknown
Due 10 December 1999
Resolved 27 December 1999
Fire Fighting
Issued 6 June 1999
Resolved
FIRE EXTINGUISHER FIRE STATION NOT PROPERLY MOUNTED.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 6 June 1999
Resolved
EMERGENCY LIGHT #140 NOT PROPERLY MOUNTED.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 6 June 1999
Resolved
FIRESCREEN DOOR STATUS INDICATOR (FSD#1102) INOP.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 6 June 1999
Resolved
WATER TIGHT DOOR EMERG EXIT NOT LABELLED.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Accommodation/Occupational Safety
Issued 6 June 1999
Resolved
AFT BRIDGE DECK STARBOARD SIDE HANDRAIL BROKEN.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Electrical
Issued 28 February 1999
Resolved
REPLACE BROKEN LIGHT COVER IN ROOM #2035.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Fire Fighting
Issued 28 February 1999
Resolved
UPDATE FIRE CONTROL PANEL ON BRIDGE TO REFLECT CORRECT CABIN NUMBER ON THE BOAT DECK.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Electrical
Issued 28 February 1999
Resolved
REPAIR/REPLACE ALL MISSING/BROKEN LIGHT COVERS IN CREW AREAS.
Condition: Unknown
Due 6 September 1999
Resolved 15 September 1999
Fire Fighting
Issued 28 February 1999
Resolved
REPAIR FSD#18C SO INDICATOR LIGHT ON BRIDGE INDICATES STATUS OF DOOR CLOSURE.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Electrical
Issued 29 November 1998
Resolved
REMOVE ALL DEAD ELECTRICAL WIRES FROM ALL SHIPBOARD AREAS.
Condition: Unknown
Due 28 May 1999
Resolved 7 June 1999
Documentation
Issued 29 November 1998
Resolved
PROVIDE FIRE CONTROL PLAN, APPROVED BY CLASSIFICATION SOCIETY.
Condition: Unknown
Due 15 September 1999
Resolved 15 September 1999
Lifesaving
Issued 29 November 1998
Resolved
REPLACE ALL LIFEBOAT'S GRAB RAILING AS ORIGINAL CONSTRUCTION.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Lifesaving
Issued 29 November 1998
Resolved
REPLACE OR RENEW LIFEBOAT'S BLOCK AND SHACKLE.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Fire Fighting
Issued 29 November 1998
Resolved
INSTALL OR RENEW FIRE DAMPERS IN SHIPBOARD AREA.
Condition: Unknown
Due 28 March 1999
Resolved 7 June 1999
Engineering
Issued 29 November 1998
Resolved
REPLACE OR RENEW RAW WATER POSITIONING CONTROLLER ON #3 SHIP SERVICE GENERATOR.
Condition: Unknown
Due 28 May 1999
Resolved 7 June 1999
Accommodation/Occupational Safety
Issued 29 November 1998
Resolved
RENEW OR REPLACE BROKEN RAMP RAILS.
Condition: Unknown
Due 28 March 1999
Resolved 7 June 1999
Lifesaving
Issued 29 November 1998
Resolved
RENEW OR REPLACE #4 LIFERAFT CONTAINER.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Navigation
Issued 29 November 1998
Resolved
RENEW OR INSTALL SOLENOID CONTROLLER COVER FOR EMERGENCY STEERING SYSTEM.
Condition: Unknown
Due 2 March 1999
Resolved 2 March 1999
Navigation
Issued 4 September 1998
Resolved
ALL FOUR HYDRAULIC RAMS LEAK FROM DRAIN PLUG SEAL.
Condition: Unknown
Due 4 September 1998
Resolved 4 September 1998
Lifesaving
Issued 4 June 1998
Resolved
TRIPPING HAZARDS AND ITEMS NOT PROPERLY STOWED THROUGHOUT VESSEL.
Condition: Unknown
Due 17 July 1998
Resolved 27 July 1998
Electrical
Issued 4 June 1998
Resolved
MAKE PERMANENT REPAIRS TO ELECTRICAL SWITCH IN PAINT LOCKER (HAZARDOUS LOCATION REQUIRES EXPLOSION PROOF FIXTURES).
Condition: Unknown
Due 17 July 1998
Resolved 27 July 1998
Lifesaving
Issued 4 June 1998
Resolved
PROVIDE PROPER MUSTER LISTS AND ESTABLISH PROPER ACCOUNTABILITY PROCEDURES FOR CREW AND PASSENGERS FOR USE IN EMERGENCY DRILLS.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Unknown
Issued 4 June 1998
Resolved
PROVE PROPER OPERATION OF PUBLIC ADDRESS SYSTEM, INCLUDING GALLEY AREAS, PRIOR TO EMBARKING PASSENGERS OR GETTING UNDERWAY.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Fire Fighting
Issued 4 June 1998
Resolved
PROVE PROPER OPERATION OF FIRE SCREEN DOORS, INCLUDING #'S 1184C, 1102C & 271C, PRIOR TO EMBARKING PASSENGERS OR GETTING UNDERWAY.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Lifesaving
Issued 4 June 1998
Resolved
PROPERLY REMOVE ALL TRASH FROM HOLD AREA AND ENSURE PROPER DISPOSAL METHODSIN PLACE TO PREVENT TRASH ACCUMULATION.
Condition: Unknown
Due 4 June 1998
Resolved 4 June 1998
Lifesaving
Issued 4 June 1998
Resolved
CONDUCT PROPER FIRE AND ABANDON SHIP DRILLS PRIOR TO EMARKING PASSENGERS ORGETTING UNDERWAY.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Unknown
Issued 4 June 1998
Resolved
PROVIDE SPARE KEY ON BRIDGE FOR ACCESS TO EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 19 June 1998
Resolved 14 July 1998
Lifesaving
Issued 4 June 1998
Resolved
VESSEL'S CREW TO RECONDUCT FIRE AND ABANDON SHIP EMERGENCY DRILLS.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Fire Fighting
Issued 4 June 1998
Resolved
INDICATOR LIGHTS FOR FIRE SCREEN DOORS NOT ALL PROPERLY WORKING.
Condition: Unknown
Due 19 June 1998
Resolved 14 July 1998
Fire Fighting
Issued 4 June 1998
Resolved
PRESSURE GUAGE FOR ENGINE ROOM FIRE PUMP NOT WORKING (AT PUMP).
Condition: Unknown
Due 17 July 1998
Resolved 27 July 1998
Lifesaving
Issued 4 June 1998
Resolved
NO WARNING SIGNS POSTED AT ELEVATOR ENTRANCES FOR FIRE DRILL PRODECURES (I.E. DO NOT USE IN CASE OF FIRE).
Condition: Unknown
Due 19 June 1998
Resolved 14 July 1998
Lifesaving
Issued 4 June 1998
Resolved
PERSONNEL HAZARD IN PASSAGEWAY GOING TO RO-RO SPACE. (SHARP CORNER OF HVY GUAGE METAL DUCTING AT HEAD LEVEL).
Condition: Unknown
Due 17 July 1998
Resolved 27 July 1998
Lifesaving
Issued 4 June 1998
Resolved
HOSPITAL SPACE NOT PROPERLY SET UP AND ITEMS NOT READILY AVAILABLE.
Condition: Unknown
Due 19 June 1998
Resolved 14 July 1998
Fire Fighting
Issued 4 June 1998
Resolved
INSTALL HEAT SENSOR IN GALLEY COLD STORAGE AREA.
Condition: Unknown
Due 17 July 1998
Resolved 27 July 1998
Fire Fighting
Issued 4 June 1998
Resolved
INDICATOR LIGHTS FOR WATERTIGHT DOORS #10 & 16 NOT PROPERLY WORKING.
Condition: Unknown
Due 19 June 1998
Resolved 14 July 1998
Lifesaving
Issued 4 June 1998
Resolved
ENSURE ALL ESCAPE EXITS ACCESSIBLE AND NOT LOCKED OR BLOCKED, PRIOR TO EMBARKING PASSENGERS OR GETTING UNDERWAY.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Fire Fighting
Issued 4 June 1998
Resolved
ESTABLISH AND PROVIDE PROPER COMMUNICATIONS ON VESSEL FOR EMERGENCY DRILLS.
Condition: Unknown
Due 25 June 1998
Resolved 14 July 1998
Fire Fighting
Issued 1 December 1997
Resolved
REMOVE ALL NON-PERMANENT CHAIRS IN STAIRWAYS PRIOR TO SAILING.
Condition: Unknown
Due 1 December 1997
Resolved 7 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
INSTALL LOW LOCATION LIGHTING SYMBOLS AT TOP AND BOTTOM OF STAIRS.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 1 December 1997
Resolved
PROVIDE AND POST MUSTER LIST IN ENGLISH IN PASSAGE WAY AFT OF NAVIGATION BRIDGE.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
PROVIDE UP-DATED FIRE CONTROL PLAN IAW SOLAS 74, II-2/20 AND SUBMIT TO USCGMARINE SAFETY CENTER (MSC).
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
PROVIDE INDICATORS FOR ALL FIRE DOORS IN MAIN VERTICAL ZONES, STAIRWAYS, AND GALLEYS.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
INSTALL GALLEY DUCT DAMPERS IAW SOLAS 74, II-2/41-2.4.3.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 1 December 1997
Resolved
REPEAT FIRE AND ABANDON SHIP DRILLS USING THE ESTABLISHED WORKING CREW LANGUAGE (ENGLISH).
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Lifesaving
Issued 1 December 1997
Resolved
PROVIDE LIFEBOAT SIGNAL CARDS AND ENGINE TOOLS FOR ALL LIFEBOATS AND COMPASS LIGHTS W/ LIQUID FOR BOATS 9 AND 10 PRIOR TO SAILING.
Condition: Unknown
Due 2 December 1997
Resolved 7 December 1997
Lifesaving
Issued 1 December 1997
Resolved
REPLACE LIFERAFT WIRE FALLS STARBOARD, FORWARD AND AFT. VESSEL IS LIMITED TO A TOTAL OF 892 PERSONS UNTIL ITEM IS COMPLETED AND IN NO CASE LATER THAN08DEC97.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Accommodation/Occupational Safety
Issued 1 December 1997
Resolved
PROVIDE DOCUMENTED PROOF THAT INSTALLED MSD IS USCG APPROVED OR USE SYSTEM AS A TYPE III SYSTEM IN U.S. WATERS.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
IF FOLLOWING AREAS ARE INTENDED TO BE USED, MODIFY IN COMPLIANCE WITH CURRENT SOLAS RULES FOR SFP AND DIRECT ACCESS; CREW & PASSENGER SAUNAS, PIZZARIA, RADIO ROOM (SHIP ENTERTAINMENT) AND INFORMATION COUNTERS/BACK OFFICES.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
PROVIDE SMOKE DETECTORS IN THE FOLLOWING LOCATIONS; DECK 5, STBD STAIRWAY FROM CREW MESS, UPPER DECK FRAME 152-158 PORT & STBD LOCKERS, DECK 4 FRAME 148 FIRE EQUIPMENT LOCKER-BACK ROOM, CINEMA TOILETS, COLD STORAGE ROOMS (MAY INSTALL HEAT DETECTORS) 31DEC98, AND BOW RAMP COMPARTMENT
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
PROVIDE FIREFIGHTING EQUIPMENT SERVICE REPORT.
Condition: Unknown
Due 5 December 1997
Resolved 7 December 1997
Fire Fighting
Issued 1 December 1997
Resolved
PROVIDE CORRECT LOCATION INFORMATION FOR THE FOLLOWING SMOKE DETECTORS; 0315, KIDS COVE, AND HAIR DRESSER.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997