Records from 1994 to 2004. Most recent: inspection, 25 May 2004.
Inspection history · 14
25 May 2004
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2078323
13 April 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2043776
10 April 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2042326
30 December 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1972144
27 October 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1940932
27 October 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2003606
17 April 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1775475
24 January 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1735043
1 December 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1712671
5 February 2002
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1484267
3 December 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295999
23 July 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 380938
25 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374949
8 June 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 367509
Fire Fighting › Fixed Fire Detection System
Issued 13 April 2004
Resolved
THREE SMOKE DETECTORS WERE FOUND MISSING. ONE LOCATED AT THE ENGINE CONTROL STATION AND TWO LOCATED IN THE LUBE OIL STORAGE COMPARTMENT. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Unknown
Due 27 May 2004
Resolved 25 May 2004
Resolution: Received fax from class attesting to the satisfactory operation of the smoke detectors in the engine room.
Electrical › Lighting (emergency)
Issued 13 April 2004
Resolved
IN THE ENGINE ROOM SEVERAL EMERGENCY LIGHTING GLOBES WERE FOUND MISSING AND/OR BLACKEND OUT. MISSING LIGHT MOUNT ASSEMBLY AT THE PORT LIFE RAFT LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 25 May 2004
Resolution: Received fax from class attesting to the satisfactory operation of the emergency lighting in the engine room.
Electrical › Electric Supply System (service)
Issued 13 April 2004
Resolved
ELECRICAL WIRES ARE EXPOSED IN THE ENGINE ROOM AND OUTSIDE ON DECK. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Due 27 May 2004
Resolved 18 May 2004
Resolution: Received fax from class attesting to the satisfactory removal of exposed wiring in the engine room.
Fire Fighting › Structural - A Class Divisions
Issued 13 April 2004
Resolved
MAIN ENTRANCE TO ENGINE ROOM CLASS A DOOR FOUND HELD BACK WITH INTALLED HOOK AND DOES NOT CLOSE AUTOMATICALLY LEGACY COMPONENT DESC: Openings - Fire Doors
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 25 May 2004
Resolution: Received fax from class attesting to the satisfactory operation of the fire door in the engine room.
Electrical › Electrical Distribution System (service)
Issued 4 February 2002
Resolved
Found electrical ground on main electric board in engine control room. SOLAS 74 I/11. (MISLE cite finder function would not allow me to choose SOLAS 74 I/11.) Repair to the satisfaction of the certificate issuing authority prior to departure from the Port of Houston. LEGACY COMPONENT DESC: Ground Detection
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2002
Resolved 5 February 2002
Resolution: Received class report stating that electrical ground caused by panel circuit terminals. System tested satisfactory.
Engineering
Issued 3 December 2001
Resolved
Oily Water Seperator not in compliance with manufacturer specification. The3 way control valve for overboard discharge has a manual by-pass valve. Marpol 73/78 REG16. Repair OWS to compliance of Marpol 73/78. Don't operatedevice until approved by class.
Condition: Unknown
Due 3 January 2002
Resolved 4 February 2002
Resolution: Vessel submitted class report stating manual by-pass option on 3 way valve removed and plugged.
Construction/Loadline
Issued 3 December 2001
Resolved
Found ventilator and hatchway covers missing securing devices due to rust and corrosion on the main deck starboard side aft. ICLL 66 REG 14(i) & REG 19(4). Repair to the satisfaction of the certificate issuing authority.
Condition: Unknown
Due 3 January 2002
Resolved 4 February 2002
Resolution: Checked hatchway securing devices and gooseneck ventilator repaired.
Navigation › Collision/Grounding Avoidance
Issued 3 December 2001
Resolved
Echo-sounding device not operating. Solas 74 Amended V/12(k). Repair to thesatification of the Certificate Issuing Authority. LEGACY COMPONENT DESC: Echo-sounding Device
Condition: Unknown
Due 27 March 2002
Resolved 28 February 2002
Resolution: Received class report attesting to satisfactory repair of echo depth sounder.
Accommodation/Occupational Safety
Issued 8 June 1994
Resolved
VSL'S TYPE II MARINE SANITATION DEVICE HAS NO LABEL OR ANY CERTIFICATION LETTER. MANUFACTURER (FERMASA) IS LISTED IN EQUIPMENT LIST BOOK BUT UNABLETO OBTAIN MODEL NUMBER FROM VSL'S CHIEF ENGINEER.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995