Records from 2016 to 2025. Most recent: operational control imposed, 12 May 2025.
Documentation record
Registered dimensions (L × B × D)54.7 ft × 14.0 ft × 4.9 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLUEWATER · MORA, MN, UNITED STATES · built 1994
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCAMP RICHARDSON, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
12 May 2025
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8127435
26 April 2025
Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8117391
13 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7909324
9 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684883
29 April 2022
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7440843
30 April 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7186308
29 April 2021
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173929
18 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6983320
5 May 2020
Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6948773
22 July 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6761756
24 May 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6421885
12 May 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147025
5 May 2016
COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873535
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2025
Resolved
Vessels over 26'...shall be provided with individual bilge suctions for each watertight compartment. Bilge suction for mid void (#2) inoperable. 46 CFR 182.25-5 Old T.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2025
Resolved 15 May 2025
Resolution: MI reattended vessel and witnessed satisfactory operation after replacement of torn o-ring in pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2025
Resolved
A visual and audible alarm must be provided at the operating station. Void #2 visual indicator at operating station inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 15 May 2025
Resolution: MI witnessed replacement of visual indicator. Tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2025
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection. Conduct drills underway to the satisfaction of the MI. 46 CFR 176.808(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2025
Resolved 15 May 2025
Resolution: MI witnessed satisfactory drills.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required fire protection servicing to the marine inspector. The vessel could not provide appropriate fire servicing report.
46 CFR 176.810(b)(1)(iv)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 22 May 2024
Resolution: Verified fire servicing report.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 May 2024
Resolved
Abandon ship, man overboard drill, and fire fighting drills and trainings shall be logged. Vessel could not provide any history of drills onboard.
46 CFR 185.520(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 30 May 2024
Resolution: Verified logs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. MI found power outlet unscrewed from bulkhead and multiple distribution panel blanks missing.
46 CFR 183.200(c)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 30 May 2024
Resolution: Verified covered distribution panels and electric outlets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 May 2023
Resolved
An adult life jacket must be provided for each person carried onboard. 47 adult pfds found onboard. Vessel limited to 45 passengers and 02 crew until 05 adult pfds are provided as per COI.
46CFR180.71
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 May 2023
Resolved 18 May 2023
Resolution: Corrected on the spot in the presence of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023
Resolved
A vessel not required to have a power driven fire pump, must have three 2.5 gallon fire buckets. Fire buckets onboard found to be 5 gallons.
46CFR181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 14 June 2023
Resolution: Three 2.5 gallon fire buckets placed onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2023
Resolved
A vessel of 26 feet in length must be provided with bilge suctions for each watertight space. Port and Stbd engine rooms not fitted with proper bilge suctions or high water alarms. Submit repair proposal to satisfaction of the MI.
46CFR182.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 15 May 2024
Resolution: Verified vessel installation of submersible bilge pumps for engine room space. Vessel did not submit a repair proposal, however, verified operation and installation of submersible bilge pumps.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2021
Resolved
A space containing an internal combustion engine of more than 50 hp must be equipped with a fixed gas fire extinguishing system, in compliance with 181.410 or other fixed fire extinguishing system specifically approved by the Commandant. Vessel is equipped with separate pre engineered extinguishing systems for each engine space and generator space. When one device is discharged it activates the other two devices. This set up is not in the spririt of the regulation by having each space controlled by a separate unit allowing the operator control of the vessel in the event of a singular fire. Pre-engineered systems must be wired separately.
46CFR181.400
Action required: 705 - Other - as specified
Resolved 13 July 2021
Resolution: Received notification that system was wired separately.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 June 2020
Resolved
Closure of openings shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Closure openings for engine compartments supply and exhaust ducts not operating or sealing openings. Repair within 7 days. 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2020
Resolved 25 June 2020
Resolution: Owner provided videos of closures operating as intended.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2020
Resolved
Each small battery installation must be located protected from falling objects. Aft generator battery missing cover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 2 July 2020
Resolution: Provided photograph of newly installed batery cover.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit required items as listed in Table 160.041 missing. Provide missing items.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 8 July 2020
Resolution: Received photo documentation of purchased first aid kit items.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 June 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications. Coast Pilot and Light List publication/extracts missing. Provide current extracts. 46 CFR 185.20-35
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 6 July 2020
Resolution: Provide chart booklet with Coast Pilot extract
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 June 2020
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Current/original COD not on board.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 June 2020
Resolved 18 June 2020
Resolution: Owner provided original Certificate of Documentation currently in effect for the vessel to the attending MI.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2017
Resolved
110V outlet on upperdeck was installed without plan review.Outlets are exposed to the weather and are not water tight. Wire is ran accross the deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 16 June 2017
Resolution: 110 wiring and outlet box was removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2017
Resolved
Wires were found hanging from overhead and resting on steering connecting rod. Required owner to re-secure wiring in overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 16 June 2017
Resolution: Wires were secured.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 12 May 2017
Resolved
Vessel has plastic waste receptacles that don't meet the requirements for Fire Protection IAW 46 CFR 177.405.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2017
Resolved 16 June 2017
Resolution: Vessel removed plastic trash cans.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 5 May 2016
Resolved
Port Engine Fire Dampers to natural ventilation opening not operational
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 5 May 2016
Resolution: Port Engine Fire Dampers to natural ventilation opening now operational.