MAURY USCG vessel records Sign in
← All vessels

MISS MALIE

MISS MALIE is a 1994 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1994, most recently in March 2022, along with 57 deficiencies and 1 operational control.

Records from 1994 to 2022. Most recent: inspection, 5 March 2022.

Built
1994
Last inspected
5 March 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCG3256
401142
Flag
UNITED STATES
—
Maury page id
psix-401142

Inspections, by type

…with no type recorded5
Years with a record 15 calendar years (1994–2022)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Gross Ton
2 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

5 March 2022 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7406199
26 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7084694
3 December 2008 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3389528
3 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3123387
8 March 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2884413
5 March 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2876179
25 August 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2474406
22 February 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2296065
10 November 2004 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2238999
21 June 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1632739
30 March 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1598829
23 March 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1060864
16 March 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1427990
22 March 2000 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393380
24 March 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404723
21 May 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1126549
8 April 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1386230
26 March 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368664
23 March 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1392644
24 June 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 699066
11 June 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 212487
11 June 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 228509
23 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355751
29 March 1996 Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355719
28 March 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357089
23 March 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1389806
23 March 1994 Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1463076

Deficiency record · 57

Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 December 2008 Resolved
Vessel failed to meet the annual inspection requirements. Complete annual inspection IAW 46 CFR 176.500 (b) (1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2022
Resolution: see special note.
Documentation › Certificates/Documents › Stability Letter
Issued 3 December 2008 Resolved
Vessel is required to complete a Pontoon Stability Test IAW MSC guidance.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2009
Resolved 5 March 2022
Resolution: See special note.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 December 2008 Resolved
19Mar09: Vsl failed to complete required drydock exam within specified time (28FEB09).
Action required: 705 - Other - as specified
Resolved 5 March 2022
Resolution: See special note.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 January 2008 Resolved
Prove proper operation of the electrical system (Nav lights, radio, etc.).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2008
Resolution: Observed proper operation of nav lights and radio.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 3 January 2008 Resolved
Prove proper operation of rpm, water temp, and oil pressure gauges.
Due 2 February 2008
Resolved 29 January 2008
Resolution: Observed satisfactory operation of rpm gauges. Oil pressure and temperature indications for these (2) outboard engines consist of red light warnings and so were not observed operating.
Engineering › Fuel Oil Service System › Hose
Issued 3 January 2008 Resolved
Provide fuel hose meeting SAE J-1942 standard (USCG Thpe A1, A2, B1, B2).
Due 2 February 2008
Resolved 29 January 2008
Resolution: Sighted proper fuel hose installed.
Fire Fighting › Fire Bucket › Quantity
Issued 3 January 2008 Resolved
Provide (2) additional fire buckets marked and with lanyard In accordance with 46CFR 181.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2008
Resolution: Sighted (3) fire buckets with lanyards.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 January 2008 Resolved
Provide current Hawaii State Registration.
Due 2 February 2008
Resolved 29 January 2008
Resolution: Sighted current HI state registration which expires 28Feb2008.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 3 January 2008 Resolved
Provide current FCC marine operator permit.
Due 2 February 2008
Resolved 29 January 2008
Resolution: Sighted valid FCC Marine Operator permit for the master [name withheld].
Engineering › Bilge Water Management System › Pump
Issued 3 January 2008 Resolved
Provide portable bilge pump with hose long enough to reach the water from the boat.
Due 2 February 2008
Resolved 29 January 2008
Resolution: Tested portable bilge pump with adequate length of hose installed.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 25 August 2005 Resolved
Provide ground wire for independent fuel tank and fill line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 October 2005
Resolution: Corrected
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 25 August 2005 Resolved
Provide proper fittings or hose clamps for fuel lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 October 2005
Resolution: Corrected
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 25 August 2005 Resolved
Provide required # of portable fire extinguishers onboard (missing 1 B-II)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 October 2005
Resolution: Correcetd
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 25 August 2005 Resolved
Provide No-Smoking sign in vicinity of Gasoline Fuel Tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 October 2005
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 25 August 2005 Resolved
Provide valid State Documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 October 2005
Resolution: Corrected
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 25 August 2005 Resolved
Provide proof of payment of user fees.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2005
Resolved 13 October 2005
Resolution: Corrected
Documentation › Certificates/Documents › FCC SSL
Issued 25 August 2005 Resolved
Provide valid FCC Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 13 October 2005
Resolution: Corrected
Documentation › Certificates/Documents › FCC SSL
Issued 25 August 2005 Resolved
Provide valid FCC Station License.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 13 October 2005
Resolution: Correcetd
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 22 February 2005 Resolved
Provide anchor and lines for inspection at the forthcoming COI inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2005
Resolved 25 August 2005
Resolution: Corrected
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 February 2005 Resolved
Replace missing latches for port & starboard embarkation gates.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2005
Resolved 25 August 2005
Resolution: Corrected
Construction/Loadline › Structures › Superstructure
Issued 22 February 2005 Resolved
Repair the cracked welds on the canopy frame at the forward stanchions.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2005
Resolved 25 August 2005
Resolution: Corrected
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 21 June 2002 Resolved
Provide valid FCC Safety Radio Certificate in accordance with 46 CFR 184.502. LEGACY COMPONENT DESC: FCC SAFETY RADIO CERTIFICATE
Condition: Unknown
Due 28 June 2002
Resolved 13 October 2005
Resolution: Corrected
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 21 June 2002 Resolved
Provide valid FCC Marine Operators Permit in accordance with 46 CFR 184.502. LEGACY COMPONENT DESC: FCC RADIO OPERATORS PERMIT
Condition: Unknown
Due 28 June 2002
Resolved 13 October 2005
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 21 June 2002 Resolved
Provide proof DAPI program is in compliance with 46 CFR part 16.
Condition: Unknown
Due 28 June 2002
Resolved 25 August 2005
Resolution: Corrected
Documentation › Logs/Records › Logbook (official)
Issued 21 June 2002 Resolved
Provide bridge log in accordance with 46 CFR 185.702.
Condition: Unknown
Due 28 June 2002
Resolved 13 October 2005
Resolution: corrected
Lifesaving
Issued 16 March 2001 Resolved
Replace (2) adult lifejackets IAW 46 CFR 180.71. Passenger count is restricted to 27 adults and 4 children until life jackets are replaced.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Lifesaving
Issued 16 March 2001 Resolved
Post lifejacket donning procedures IAW 46 CFR 185.516.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Engineering
Issued 16 March 2001 Resolved
Replace short lengths of fuel hose with approved hose meeting construction standards of SAE J-1527 or labeled USCG Type A or B, IAW 46 CFR 182.720.
Condition: Unknown
Due 26 March 2001
Resolved 26 March 2001
Navigation
Issued 8 April 1998 Resolved
Provide Navigation Rules and chart.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Electrical
Issued 8 April 1998 Resolved
Remove or safe-end dead ended wires in console.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Fire Fighting
Issued 8 April 1998 Resolved
Replace missing safety keys on two B-II portable fire extinguishers.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Engineering
Issued 8 April 1998 Resolved
Install ferrous gasoline fuel pipe as required by 46 CFR 182.810(c), or approved flexible nonmetallic hose complete with appropriate end fittings as allowed by 46 CFR 182.720(e), and anti-siphon protection as required by 46 CFR 182.455(b)(1).
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Unknown
Issued 8 April 1998 Resolved
Provide evidence of payment of vessel user fee for 1998.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Electrical
Issued 8 April 1998 Resolved
Install overload protection and emergency disconnect for port battery.
Condition: Unknown
Due 8 April 1998
Resolved 8 April 1998
Unknown
Issued 29 March 1996 Resolved
Provide log for all crew training iaw IFR 46CFR185.420
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Electrical
Issued 29 March 1996 Resolved
Provide 2 portable lights. 1 for helm station, 1 for Engine area.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Lifesaving
Issued 29 March 1996 Resolved
Provide emergency broadcast placard iaw IFR 46CFR184.506.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Lifesaving
Issued 29 March 1996 Resolved
CONDUCT AND LOG ABANDON SHIP & MAN OVERBOARD DRILLS IAW IFR 46CFR185.520
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 29 March 1996 Resolved
CONDUCT & LOG FIREFIGHTING DRILLS IAW IFR 46CFR185.524
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Engineering
Issued 29 March 1996 Resolved
LABEL EMERGENCY FUEL SHUTOFF VALVE IAW IFR 46CFR185.608
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 29 March 1996 Resolved
Provide FCC safety radio certificate. Copy of submitted application will satisfy this requirement.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Construction/Loadline
Issued 29 March 1996 Resolved
Provide positive shuttoff valves at hull penetrations for bilge system iaw IFR 46CFR182.520(e).
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 29 March 1996 Resolved
Provide copy of Company Drug and Alcohol Policy.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Fire Fighting
Issued 29 March 1996 Resolved
Provide proper bracket for B-II extinguisher iaw 46CFR181.30-5 and approvallabel.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Unknown
Issued 29 March 1996 Resolved
Provide company Employee Assistance Policy iaw Title 16.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Navigation
Issued 29 March 1996 Resolved
Provide anchor dayshape.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Engineering
Issued 29 March 1996 Resolved
Provide ground strap for fuel fill pipe IAW 46CFR182.15-30(d).
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 29 March 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Documentation
Issued 29 March 1996 Resolved
Provide proof of valid state registration.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Unknown
Issued 29 March 1996 Resolved
CONDUCT & LOG ANNUAL INSPECTION IAW IFR 46CFR185.726
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Unknown
Issued 29 March 1996 Resolved
Establish log for passenger count IAW IFR 46CFR185.502
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Unknown
Issued 29 March 1996 Resolved
Provide a written copy of Passenger safety orientation required by IFR 46CFR185.506.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Lifesaving
Issued 29 March 1996 Resolved
Provide PFD placards IAW IFR 46CFR185.516.
Condition: Unknown
Due 29 March 1996
Resolved 29 March 1996
Engineering
Issued 28 March 1995 Resolved
PROVIDE PROPER GROUNDING MEANS FOR FUEL FILL PIPE W/ FLEXIBLE HOSE SECTIONS, IAW 46 CFR 182.15-30(d).
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995 Resolved
PROVIDE PROPER LABELLING AND REMOTE OPERATING MEANS FOR FUEL SHUT OFF VALVE(PULL WIRE W/ RING OUTSIDE OF TANK SPACE), IAW 46 CFR 182.15-40(b)(3) and 46 CFR 185.30-20(a).
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Documentation
Issued 28 March 1995 Resolved
PROVIDE FCC SAFETY CERTIFICATE FOR VESSEL. VESSEL IS RESTRICTED TO NOT MORETHAN 1000 FEET FROM SHORE UNTIL REQUIRMENT IS CLEARED.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 28 March 1995 Resolved
PROVIDE PROPER METAL MARINE TYPE FUEL STRAINER, ONE FOR EACH OUTBOARD FUEL LINE, IAW 182.15-40(b)(5).
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.