Records from 2016 to 2020. Most recent: inspection, 13 July 2020.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 July 2020
No resolution recorded
Vessel inspected under subcahpter T may not operate without having on board a valid USCG COI. Vessel annual inspection is overdue.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 January 2019
Resolved
VSL on LSW route must have (06) red and (06)orange flares. Provide (08) additional red flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 25 January 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 January 2019
Resolved
Fixed Fire Fighting system must be test and service annually by qualified Individual.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 25 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2019
Resolved
VSL must have type i life jackets for every persons on board. VSL have (39) life jackets. Provide additional (03) adult life jackets to meet max number of persons on board (51)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 25 January 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 January 2019
Resolved
Crew drills must be conduct every three months and logged in a vessel log book.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 25 January 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 January 2019
Resolved
Vessel must have valid FCC station license Provide proof of valid FCC station license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2019
Resolved 25 January 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 5 April 2018
Resolved
Starboard propulsion engines had internal failures, caused engine to overheated and seized. Conduct repairs IAW engine manufacture instructions. No passenger carry until repairs are complete and attest by attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2018
Resolved 23 January 2019
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 November 2017
Resolved
Master must conduct drills as required by 46 CFR 185.25-10. Provide proof of performed drills.
Due 15 December 2017
Resolved 1 December 2017
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 November 2017
Resolved
Emergency Check off list must be post in a conspicuous space accessible to crew and passenger as required by 46 CFR 185.25-1. Post emergency check off list.
Due 15 December 2017
Resolved 2 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 November 2017
Resolved
Life preserver stowage must be marked as required by 46 CFR 185.30-10. Marked life preserver storage with at least 1 inch letters and figures.
Due 15 December 2017
Resolved 1 December 2017
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 November 2017
Resolved
Vessel must carry adequate and up-to-date notice to mariners, a copy of navigation rules and tide tables as required by 46 CFR 185.20-35. Provide missing nautical publications.
Due 15 December 2017
Resolved 1 December 2017
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 November 2017
Resolved
Vessel must be fitted with suitable comapass as required by 46 CFR 184-20-1. Repair in- operatble light on compass.
Due 15 December 2017
Resolved 1 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 November 2017
Resolved
Each life preserver must have at least 31 square inch of retro reflective material attached on its front and back as required by 46 CFR 180.25-25. Replace old retro reflective material on 17 adult life preservers. Max number of passenger carry is 31.
Due 15 December 2017
Resolved 2 December 2017
Lifesaving › Lifebuoys › Serviceable
Issued 30 November 2017
Resolved
Ring life buoy must be in good and serviceable conditions as required by 46 CFR 180.30-1. Replace damaged ring life buoy.
Due 15 December 2017
Resolved 1 December 2017
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 30 November 2017
Resolved
All vessel shall be provided with hand operated portable fire pump having capacity of at least 5 gallons per minute as required by 46 CFR 181.10-5. Provide hand fire pump.
Due 15 December 2017
Resolved 1 December 2017
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 30 November 2017
Resolved
Vessel engines must have gages to indicate engine cooling discharge temperatures and lubrication oil pressures as required by 46 CFR 182.20-5. Replace inoperable engine oil pressure gages and engine temperature gages on port and starboard engines.
Due 15 December 2017
Resolved 2 December 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 30 November 2017
Resolved
Propulsion machinery shall be proper operating condition and fit for the service for which they are intended as required by 46 CFR 176.25-10. Replace damaged oil line to turbo on starboard engine.
Due 15 December 2017
Resolved 1 December 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 30 November 2017
Resolved
Propulsion machinery shall be proper operating condition and fit for the service for which they are intended as required by 46 CFR 176.25-10. Install missing air filter on port engine.
Due 15 December 2017
Resolved 1 December 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 November 2017
Resolved
Propulsion machinery shall be proper operating condition and fit for the service for which they are intended as required by 46 CFR 176.25-10. Repair salt water leaks on starboard engine exhaust.
Due 15 December 2017
Resolved 1 December 2017
Engineering › Fuel Oil Service System › Ventilation
Issued 2 October 2017
Resolved
Diesel tank vent screen shall be corrosion resistant wire of at least 30 x 30 mesh as required by 46 CFR 182.20-35. Install missing screen on tank vents.
Due 15 December 2017
Resolved 2 December 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 October 2017
Resolved
Bilge alarms shall be proper operating condition and fit for the service for which they are intended as required by 46 CFR 176.25-40. Repair inoperable bilge alarm in starboard engine room.
Due 15 December 2017
Resolved 2 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 September 2016
Resolved
Each life jacket must be marked with type I retro reflective material as required by 16 CFR 185.604. Replace all identified old and faded retro reflective material. Number of persons carry is reduced to 43 until (08) adult lifejackets are provided with proper retro reflective material.
Due 23 September 2016
Resolved 9 September 2016
Navigation › Piloting/Steering › Magnetic Compass
Issued 9 September 2016
Resolved
Vessel must be fitted with a suitable magnetic compass designed for marine use as required by 46 CFR 184.402. Replace damaged compass.
Due 23 September 2016
Resolved 22 September 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2016
Resolved
Vessel must have navigation lights that are in compliance with Inland navigation rules as required by 46 CFR 182.420. Repair inoperable mast light.
Due 23 September 2016
Resolved 9 September 2016
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 September 2016
Resolved
Provide proof of required servicing for FGFE and portable CO2 fire extinguisher as required by 46 CFR 176.810.
Due 23 September 2016
Resolved 9 September 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 September 2016
Resolved
Repair salt water leak on port engine cooling system as required by 46 CFR 176.804.
Due 23 September 2016
Resolved 22 September 2016
Engineering › Lubricating Oil Service System › Hose
Issued 9 September 2016
Resolved
Install chafing gear on STBD reduction gear oil supply as required by 46 CFR 176.804.
Due 23 September 2016
Resolved 22 September 2016
Engineering › Sea-water System (primary cooling) › Pump
Issued 9 September 2016
Resolved
Tighten lose drive belt on port engine as required by 46 CFR 176.804
Due 23 September 2016
Resolved 22 September 2016
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 9 September 2016
Resolved
Repair inoperable engine temperature gauge on STBD engine as required by 46 CFR 182.410
Due 23 September 2016
Resolved 22 September 2016
Engineering › Fuel Oil Service System › Valve
Issued 9 September 2016
Resolved
Fuel shutoff station must be marked in clearly legible letter at 1 inch high as required by 46 CFR 185.608
Due 23 September 2016
Resolved 22 September 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 September 2016
Resolved
Installation and location must be to the satisfactory of the OCMI as required by 46 CFR 181.520. Replace all identified wasted mounting brackets.
Due 23 September 2016
Resolved 22 September 2016
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2016
Resolved
A visual and audible alarm must be provided at the operation station to indicate high water level in unmanned spaces as required bu 46 CFR 182.530
Due 23 September 2016
Resolved 9 September 2016