MAURY USCG vessel records Sign in
← All vessels

SEA STAR

SEA STAR is a 1994 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1994, most recently in June 2026, along with 85 deficiencies, 1 operational control and 6 casualty investigations between 2008 and 2024.

Records from 1994 to 2026. Most recent: inspection, 9 June 2026.

Built
1994
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCF4121
401297
Flag
UNITED STATES
368359980
Maury page id
psix-401297

Inspections, by type

…with no type recorded7
Years with a record 31 calendar years (1994–2026)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.3 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN YACHTS · TARPON SPRINGS FL · built 1994
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5055MMSI 368359980 · active · compulsorily equipped · granted 30 March 2024, expires 30 March 2034
WDH3352MMSI 367606810 · expired · compulsorily equipped · granted 21 February 2014, cancelled 27 April 2024
WCF4121MMSI 366575530 · expired · voluntarily equipped · granted 30 March 2004, cancelled 14 June 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

9 June 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8368829
10 March 2026 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8323341
15 May 2025 COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8116441
22 August 2024 Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7987296
22 August 2024 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7987730
15 August 2024 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7982540
15 August 2024 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7984431
28 May 2024 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7921238
12 February 2024 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7871206
23 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7694522
19 April 2023 In-Service Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7671476
27 May 2022 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465435
27 May 2022 Deficiency Check · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465666
9 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7447862
8 February 2022 Drydock Exam · Internal Structural Exam · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7393003
28 December 2021 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7386233
7 May 2021 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7191697
20 September 2020 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7074558
18 May 2020 Deficiency Check · DAPI Audit · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6955347
27 February 2020 Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6917010
5 September 2019 Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6810126
31 July 2018 Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661163
14 February 2018 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6576707
22 September 2017 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294245
25 April 2017 Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6229728
1 August 2016 DAPI Audit · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5963101
26 April 2016 Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5865499
2 May 2014 Administrative Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4847309
19 July 2012 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4406795
27 July 2011 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4095058
29 March 2010 Hull Examination · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3704864
4 March 2009 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3427490
30 October 2008 Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 3354713
30 October 2008 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3354835
13 May 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3205262
10 March 2008 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3161475
5 April 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2901642
5 July 2006 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2702439
24 May 2006 Deficiency Check · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2655626
7 March 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2597749
2 May 2005 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2347491
5 May 2004 Annual Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2054646
2 March 2004 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1988831
13 May 2003 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1788485
23 July 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1651001
29 April 2002 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1610548
19 March 2002 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1495662
31 May 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1444541
9 May 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1412091
21 March 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1406674
13 August 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1462002
16 June 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126114
25 March 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788270
20 May 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099322
5 June 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086952
8 May 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1077928
19 March 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1077620
10 July 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883255
5 July 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1193597
1 June 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1181790
21 October 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183664
22 August 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 862671
10 May 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 859192
11 March 1994 Plan Review "T" Boat · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 853026

Deficiency record · 85

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 June 2026 Resolved
Life floats don't have the proper batteries in the lights. Replace with correct batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 June 2026 Resolved
STBD life float needs new paint.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 15 May 2025 Resolved
04 Spring clips are not working properly on gates. Repair or replace spring clips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 16 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2025 Resolved
02 of the required 03 portable fire extinguisher are going to need annual inspection by the end of the month.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 16 May 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 August 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel suffered an approximately 6" by 6" crack to the starboard hull, amidship, after an allision with a concrete pier. Submit plan for repairs with resign type and and lay up schedule to follow manufacture build plans. Affect permanent repairs of the hull to the satisfaction of a USCG Marine Inspector prior to the carriage of passengers. 46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2024
Resolution: Vessel has completed fiber glass repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023 Resolved
First aid kit was found with expired eye wash and aspirin. Replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 May 2023 Resolved
Both life floats were faded with a lot of black from the FL sun and no tag on weak link to identify proper size. Repaint both life floats and either provide proof of size for weak link or replace with new weak link.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 May 2022 Resolved
Repair or replace non-functional Starboard side engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2022
Resolved 6 June 2022
Resolution: Repowered with 2 new outboards, conducted satisfactory sea trials
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 May 2022 Resolved
FCC Safety Certificate expired Aug 2021. Must renew FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 24 May 2022
Resolution: Received photographic image from company representative, of recently issued FCC Safety Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 May 2022 Resolved
Life float paddles were not the correct size. Must be able to extend to 4 feet long. Replace all 4 paddles and label with vessels name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 16 May 2022
Resolution: 4 new paddles that extend to 54 inches with vessel's name affixed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2021 Resolved
3 fire buckets found to be only 2 gallons. Requirement is minumum 2.5 gallons. Must replace all 3 fire buckets with atleast 2.5 gallon buckets, label properly and attach lanyards as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 15 June 2021
Resolution: All 3 fire buckets were replaced with correct size and labeled properly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 May 2021 Resolved
Life float needs to be labeled properly with vessels name and passenger count.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 13 May 2021
Resolution: Labeled life float properly
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2020 Resolved
Life ring strobe light is extinguished, renew or repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Life ring strobe battery was replaced and light was verified to be in good working order.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020 Resolved
Life jacket donning placard is not legible, renew placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Life jacket donning placard was renewed and placed on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020 Resolved
First aid kit is missing contents. Provide all contents per 46 cfr 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Proper first aid kit was purchased and placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2019 Resolved
Life float lines are incorrectly stowed and life float needs paint and new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Life float lines were properly stowed and float was re-painted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2019 Resolved
Life ring lanyard is wasted. Renew with 60’ of polypropylene line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Life ring lanyard was renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2019 Resolved
Update expired contents in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: New Kit was supplied.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2019 Resolved
Port bilge automatic operation light is extinguished. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Bulb was replaced, and tested all sat.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 5 September 2019 Resolved
VHF must be linked to GPS and have MMSI number input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: New Radio was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2019 Resolved
Batteries are not secured in battery box. Provide box and install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Battery boxes were properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 September 2019 Resolved
Renew reflective material on any PFD missing 25% or more. Mark all stowage with size and quantity
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2019
Resolution: All PFD were cleaned and reflective material replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2018 Resolved
6 adult PFD were foun not servicable. Renew PFD prior to carring more than 43 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Renewed Lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 31 July 2018 Resolved
life ring bouy is missing 60' of floating line. provide and attach to ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Provided and attached.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 July 2018 Resolved
Provide new FCC documents with new onwer info. (station License and EPIRB)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 31 July 2018 Resolved
Post COI, Garbage placards, and Oil placard, emergency broadcast placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Posted
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2018 Resolved
Provide crew for drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 25 April 2017 Resolved
Large section of AFT deck has been removed to replace broken deck frame. Complete repairs and tes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: New deck frame was installed to original specs, and new marine grade plywood cored frp deck was installed. Water tested all sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 April 2017 Resolved
15 Adult PFD are no longer serviceable. They were removed from the vessel and distroyed. Provide new PFD.
Action required: 705 - Other - as specified
Resolved 9 May 2017
Resolution: New PFD were provided and marked.
Lifesaving › Lifefloat › Lifeline
Issued 25 April 2017 Resolved
Life float straps that hold the netting and the grablines in place are failing. Repair/replace.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New straps were installed and tested. All sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2017 Resolved
Life float strobes are not mounted. Mount to prevent accidental activation.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New mounts were installed.
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2017 Resolved
Port fuel tank remote shut-off valve is damaged. Repair/renew.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New valve was installed and tested all sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 25 April 2017 Resolved
Compass light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Compass light was replaced and tested, all sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 April 2017 Resolved
Life ring is missing reflective tape. Repair/renew.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New SOLAS tape was applied.
Navigation › Piloting/Steering › Marine Charts
Issued 1 August 2016 Resolved
Vessel does not have charts onboard.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Resolution: New charts were provided. Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 August 2016 Resolved
4 PFDs were found wasted. internal foam had turned into dust.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Resolution: New PFDs were provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 August 2016 Resolved
LPFD stowage was not marked and child/adult PFDs were not seperated.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: New stowage marked to match actual storage.
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 1 August 2016 Resolved
Life ring grablines were wasted, and retro was missing.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Resolution: New Life Ring was Provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 August 2016 Resolved
Vessel did not have a valid Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 26 August 2016
Resolution: New FCC safety cert was provided.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 1 August 2016 Resolved
Vessel did not have a waste management plan.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: New waste management plan was provided and posted.
Lifesaving › Lifefloat › Lifeline
Issued 19 July 2012 Resolved
Life-line attaching the two Lifefloats together is disconnected, reattach line to both Lifefloats.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2012
Resolution: New Lifeline installed to attach the two Lifefloats together. All sat.
Lifesaving › Lifefloat › Serviceable
Issued 19 July 2012 Resolved
Both Lifefloats are covered with black mold, clean mold from Lifefloats, repaint if not bright orange after cleaning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2012
Resolved 6 August 2012
Resolution: Both Lifefloats were cleaned and repainted. All sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 July 2012 Resolved
Port fuel shut off valve missing handle, install new handle and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2012
Resolution: New valve handle installed. All sat.
Fire Fighting › Fire Bucket › Lanyard
Issued 27 July 2011 Resolved
Vessel has five gallon buckets none of them are marked, or have lanyards. Install three buckets at least 2.5 gallons in size with length of lanyard that will allow it to reach the water line and properly label fire bucket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 26 August 2011
Resolution: Fire buckets properly installed on vessel.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 27 July 2011 Resolved
Provide 3 lifelines at each hand rail opening. As per discussion.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 26 August 2011
Resolution: All new life lines installed at hand rail openings.
Communications › Radio Communications › EPIRB
Issued 27 July 2011 Resolved
Hydrostatic release expired, no date indicated, renew hydrostatic release and properly mark date of expiration, 2 years from date of installation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2011
Resolution: New hydrostatic release properly installed.
Lifesaving › Lifefloat › Serviceable
Issued 27 July 2011 Resolved
Both lifefloats have wasted straps, covers, and lines. Repair or replace lifefloats. On 4 Aug 2011 received copy of invoice showing owner ordered 2 new lifefloats, expected delivery date is 2 weeks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 26 August 2011
Resolution: New lifefloats installed on vessel. All sat.
Construction/Loadline › Structures › Deck Plating
Issued 27 July 2011 Resolved
Properly repair delaminated fiberglass deck as marked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 26 August 2011
Resolution: Delamination of main deck properly repaired.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 27 July 2011 Resolved
Lock sewage Y valve in deck discharge position, keep deck suction pipe capped at all times.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: Crew put padlock on Y valve during annual inspection.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 27 July 2011 Resolved
Found 6 orange day smoke signals expired, vessel had 12 red hand flares on board, allowed vessel to operate until new day signals are provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2011
Resolved 28 July 2011
Resolution: 6 new orange day smoke signals provided.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 July 2011 Resolved
Operator could not find Vessel COD during inspection, Owner called Vessel Documentation Center during inspection and confirmed current Documentation. Received e-mail copy of COD, owner ordered new original COD.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2011
Resolution: E-mail copy of COD provided by VDC. New original ordered.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 July 2011 Resolved
Properly label bilge alarm indicator light.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2011
Resolved 26 August 2011
Resolution: Bilge alarms properly labeled.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 April 2010 Resolved
Life line on lifebuoy is not made of buoyant material. Provide 60' of buoyant lifeline attached to lifebuoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 May 2010
Resolved 12 May 2010
Resolution: Received e-mail picture of new life line installed on lifebuoy. All sat.
Stability › Watertight Integrity › General
Issued 30 March 2010 Resolved
Sump pump box for toilet compartment drain not connected and not operational. Make repairs to sump drain and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 22 April 2010
Resolution: New sump box installed, all sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 30 March 2010 Resolved
Sight glass for sewage tank cracked and allowing sewage to leak into bilge. Replace sight glass as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2010
Resolved 22 April 2010
Resolution: Repairs made to sewage tank. All sat.
Lifesaving › Lifefloat › Lifeline
Issued 29 March 2010 Resolved
Lifefloat life line holder is broken, repair or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2010
Resolved 12 May 2010
Resolution: Proper repair made to life line holder. All sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 March 2010 Resolved
Provide proof of written drug testing program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2010
Resolved 12 May 2010
Resolution: Drug testing program in place. All sat.
Communications › Radio Communications › EPIRB
Issued 4 March 2009 Resolved
Prove proper servicing of EPIRB, battery expired 09/2008. Vessel restricted to NMT 3 miles from shore until cleared.
Action required: 705 - Other - as specified
Due 4 April 2009
Resolved 6 March 2009
Lifesaving › Hand Flares › Quantity
Issued 24 May 2006 Resolved
Provide additional distress flares, 3 red hand held and 3 orange smoke flares, IAW 46 CFR 180.68(a)(1) & (2) to bring total to 6 red and 6 orange.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2006
Resolved 25 May 2006
Lifesaving › Lifefloat › Pendant
Issued 24 May 2006 Resolved
Replace all deteriorating grab lines on lifefloats.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 5 July 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 May 2006 Resolved
Provide USCG Light List and U.S. Coast Pilot onboard vessel.
Action required: 705 - Other - as specified
Due 24 June 2006
Resolved 5 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2005 Resolved
Replace Portside navigational light lense.
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 26 May 2005
Lifesaving › Lifefloat › Paddle
Issued 2 May 2005 Resolved
Ensure paddles are adequately lashed to lifefloats
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 26 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2005 Resolved
Repair or remove flourescent light fixture inside starboard hull aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 June 2005
Resolved 26 May 2005
Lifesaving › Lifebuoys
Issued 29 April 2002 Resolved
Provide 60ft painter for ring buoy using black, UV resistant floating line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 23 July 2002
Resolution: Corrected.
Lifesaving › Buoyant Apparatus
Issued 29 April 2002 Resolved
Repair or replace both 18 person Buoyant Apparatus. If replaced, replace with approved life floats with an aggregate capacity of 50% of the total persons allowed by the vessel's COI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 23 July 2002
Resolution: Corrected. BA''s replaced with 2 new 15 person life floats.
Lifesaving › Buoyant Apparatus
Issued 29 April 2002 Resolved
Properly attach vessel's Buoyant Apparatus to 100ft painter and provide appropriately sized weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 7 May 2002
Resolution: Corrected.
Lifesaving
Issued 31 May 2001 Resolved
Clean the B/As._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 2001
Resolved 5 June 2001
Lifesaving
Issued 31 May 2001 Resolved
Replace/repair the life ring buoy._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 7 June 2001
Resolved 5 June 2001
Fire Fighting
Issued 31 May 2001 Resolved
Have all fire extinguishers serviced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 2001
Resolved 5 June 2001
Electrical
Issued 31 May 2001 Resolved
Provide battery boxes for the batteries._x001C_ _x001C_ This item to be corrected prior to carrying passengers._x001C_ _x001C_
Condition: Unknown
Due 7 June 2001
Resolved 5 June 2001
Lifesaving
Issued 31 May 2001 Resolved
Provide a watertight container for the distress flares._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 7 June 2001
Resolved 5 June 2001
Documentation
Issued 9 May 2000 Resolved
Provide a current Vessel Documentation Certificate._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 2000
Resolved 10 May 2000
Lifesaving
Issued 9 May 2000 Resolved
Provide a waterlight for both B/As and provide a proper painter._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 2000
Resolved 17 May 2000
Lifesaving
Issued 9 May 2000 Resolved
Replace the hydrostatic release on the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 2000
Resolved 17 May 2000
Construction/Loadline
Issued 9 May 2000 Resolved
Repair the starboard high-level bilge alarm._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 9 June 2000
Resolved 17 May 2000
Lifesaving
Issued 9 May 2000 Resolved
Affix new line to the life ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 June 2000
Resolved 17 May 2000
Documentation
Issued 8 May 1996 Resolved
Replace the marine document._x001C_ Unable to verify its authenticity due to lamination.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Documentation
Issued 8 May 1996 Resolved
Provide evidence that you filed a MIS report for 1995. Also; provide a allrandom and pre-employment drug tests for 1995 and any pre-employment test for 1996.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 8 May 1996 Resolved
Replace retro-reflective material on 9 adult and 5 child lifejackets._x001C_ Vessel is restricted to 42 adults (passengers and crew) and 1 child until retro is replaced.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Documentation
Issued 1 June 1995 Resolved
Obtain an another marine document._x001C_ (DO NOT LAMINATE)
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Lifesaving
Issued 1 June 1995 Resolved
Repair waterlight on port buoyant apparatus._x001C_ Starboard waterlight appears very weak.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Engineering
Issued 1 June 1995 Resolved
Replace starboard fueltank vent. (currently held in place with RTV)_x001C_ Replace missing 30 X 30 mesh wire screen on both vents.
Condition: Unknown
Due 1 June 1995
Resolved 1 June 1995
Engineering
Issued 10 May 1994 Resolved
Install fuel fill pipe to extend to within 3/4" of tank bottom and increasefuel tank vent to 3/4".
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994
Engineering
Issued 10 May 1994 Resolved
Mark/label fuel shut off valve.
Condition: Unknown
Due 10 May 1994
Resolved 10 May 1994

Casualty record · 6

30 October 2008Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3354835
12 November 2011Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 4188270
20 September 2020Routine · role: Involved in a Marine Casualty · 1 injured · activity 7074558
28 December 2021Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 7386233
27 May 2022Routine · role: Involved in a Marine Casualty · activity 7465435
15 August 2024Routine · role: Involved in a Marine Casualty · activity 7984431
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.