Inspection history · 27
9 June 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8368829
10 March 2026
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8323341
15 May 2025
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8116441
22 August 2024
Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7987296
22 August 2024
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7987730
15 August 2024
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7982540
15 August 2024
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7984431
28 May 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7921238
12 February 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7871206
23 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7694522
19 April 2023
In-Service Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7671476
27 May 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465435
27 May 2022
Deficiency Check · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7465666
9 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7447862
8 February 2022
Drydock Exam · Internal Structural Exam · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7393003
28 December 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7386233
7 May 2021
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7191697
20 September 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7074558
18 May 2020
Deficiency Check · DAPI Audit · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6955347
27 February 2020
Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6917010
5 September 2019
Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6810126
31 July 2018
Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6661163
14 February 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6576707
22 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294245
25 April 2017
Internal Structural Exam · Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6229728
1 August 2016
DAPI Audit · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5963101
26 April 2016
Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5865499
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 June 2026
Resolved
Life floats don't have the proper batteries in the lights. Replace with correct batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 June 2026
Resolved
STBD life float needs new paint.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2026
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 15 May 2025
Resolved
04 Spring clips are not working properly on gates. Repair or replace spring clips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 16 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2025
Resolved
02 of the required 03 portable fire extinguisher are going to need annual inspection by the end of the month.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 16 May 2025
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 August 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Vessel suffered an approximately 6" by 6" crack to the starboard hull, amidship, after an allision with a concrete pier.
Submit plan for repairs with resign type and and lay up schedule to follow manufacture build plans. Affect permanent repairs of the hull to the satisfaction of a USCG Marine Inspector prior to the carriage of passengers.
46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2024
Resolution: Vessel has completed fiber glass repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023
Resolved
First aid kit was found with expired eye wash and aspirin. Replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 May 2023
Resolved
Both life floats were faded with a lot of black from the FL sun and no tag on weak link to identify proper size. Repaint both life floats and either provide proof of size for weak link or replace with new weak link.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2023
Resolved 20 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 May 2022
Resolved
Repair or replace non-functional Starboard side engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2022
Resolved 6 June 2022
Resolution: Repowered with 2 new outboards, conducted satisfactory sea trials
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 May 2022
Resolved
FCC Safety Certificate expired Aug 2021. Must renew FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 24 May 2022
Resolution: Received photographic image from company representative, of recently issued FCC Safety Radiotelephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 May 2022
Resolved
Life float paddles were not the correct size. Must be able to extend to 4 feet long. Replace all 4 paddles and label with vessels name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 16 May 2022
Resolution: 4 new paddles that extend to 54 inches with vessel's name affixed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2021
Resolved
3 fire buckets found to be only 2 gallons. Requirement is minumum 2.5 gallons. Must replace all 3 fire buckets with atleast 2.5 gallon buckets, label properly and attach lanyards as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 15 June 2021
Resolution: All 3 fire buckets were replaced with correct size and labeled properly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 May 2021
Resolved
Life float needs to be labeled properly with vessels name and passenger count.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 13 May 2021
Resolution: Labeled life float properly
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2020
Resolved
Life ring strobe light is extinguished, renew or repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Life ring strobe battery was replaced and light was verified to be in good working order.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020
Resolved
Life jacket donning placard is not legible, renew placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Life jacket donning placard was renewed and placed on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2020
Resolved
First aid kit is missing contents. Provide all contents per 46 cfr 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 June 2020
Resolution: Proper first aid kit was purchased and placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2019
Resolved
Life float lines are incorrectly stowed and life float needs paint and new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Life float lines were properly stowed and float was re-painted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2019
Resolved
Life ring lanyard is wasted. Renew with 60’ of polypropylene line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Life ring lanyard was renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2019
Resolved
Update expired contents in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: New Kit was supplied.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 September 2019
Resolved
Port bilge automatic operation light is extinguished. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Bulb was replaced, and tested all sat.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 5 September 2019
Resolved
VHF must be linked to GPS and have MMSI number input.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: New Radio was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 September 2019
Resolved
Batteries are not secured in battery box. Provide box and install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 September 2019
Resolution: Battery boxes were properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 September 2019
Resolved
Renew reflective material on any PFD missing 25% or more. Mark all stowage with size and quantity
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2019
Resolution: All PFD were cleaned and reflective material replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 July 2018
Resolved
6 adult PFD were foun not servicable. Renew PFD prior to carring more than 43 passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Renewed Lifejackets
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 31 July 2018
Resolved
life ring bouy is missing 60' of floating line. provide and attach to ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Provided and attached.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 July 2018
Resolved
Provide new FCC documents with new onwer info. (station License and EPIRB)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 31 July 2018
Resolved
Post COI, Garbage placards, and Oil placard, emergency broadcast placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Posted
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2018
Resolved
Provide crew for drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2018
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 25 April 2017
Resolved
Large section of AFT deck has been removed to replace broken deck frame. Complete repairs and tes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2017
Resolution: New deck frame was installed to original specs, and new marine grade plywood cored frp deck was installed. Water tested all sat.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 25 April 2017
Resolved
15 Adult PFD are no longer serviceable. They were removed from the vessel and distroyed. Provide new PFD.
Action required: 705 - Other - as specified
Resolved 9 May 2017
Resolution: New PFD were provided and marked.
Lifesaving › Lifefloat › Lifeline
Issued 25 April 2017
Resolved
Life float straps that hold the netting and the grablines in place are failing. Repair/replace.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New straps were installed and tested. All sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2017
Resolved
Life float strobes are not mounted. Mount to prevent accidental activation.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New mounts were installed.
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2017
Resolved
Port fuel tank remote shut-off valve is damaged. Repair/renew.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New valve was installed and tested all sat.
Navigation › Piloting/Steering › Magnetic Compass
Issued 25 April 2017
Resolved
Compass light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: Compass light was replaced and tested, all sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 April 2017
Resolved
Life ring is missing reflective tape. Repair/renew.
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 9 May 2017
Resolution: New SOLAS tape was applied.
Navigation › Piloting/Steering › Marine Charts
Issued 1 August 2016
Resolved
Vessel does not have charts onboard.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Resolution: New charts were provided. Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 August 2016
Resolved
4 PFDs were found wasted. internal foam had turned into dust.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Resolution: New PFDs were provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 August 2016
Resolved
LPFD stowage was not marked and child/adult PFDs were not seperated.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: New stowage marked to match actual storage.
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 1 August 2016
Resolved
Life ring grablines were wasted, and retro was missing.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 1 August 2016
Resolution: New Life Ring was Provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 1 August 2016
Resolved
Vessel did not have a valid Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 26 August 2016
Resolution: New FCC safety cert was provided.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 1 August 2016
Resolved
Vessel did not have a waste management plan.
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 1 August 2016
Resolution: New waste management plan was provided and posted.