MAURY USCG vessel records Sign in
← All vessels

GENERAL PATTON

GENERAL PATTON is a 1944 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 1994, most recently in December 2010, along with 32 deficiencies.

Records from 1994 to 2010. Most recent: inspection, 6 December 2010.

Built
1944
Last inspected
6 December 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

401460
Flag
UNITED STATES
—
Maury page id
psix-401460

Inspections, by type

…with no type recorded3
Years with a record 12 calendar years (1994–2010)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MISS JUDY Passenger (Inspected) · MISLE 372560 · 30 September 1994 · activity 104112

Inspection history · 19

6 December 2010 Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 3905604
18 April 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2911713
18 April 2006 COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2626718
17 May 2005 Re-Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2361458
11 May 2004 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2064322
6 August 2003 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1861937
1 May 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1063860
29 March 2001 COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1468224
5 August 1999 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 824857
12 July 1999 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365447
27 May 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 804355
9 March 1999 Re-Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1456671
27 May 1998 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1126217
12 March 1998 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1421467
11 March 1997 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1435913
13 March 1996 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1080167
30 September 1994 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 104112
2 July 1994 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 48876
17 February 1994 Initial Certification · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 853240

Deficiency record · 32

Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 April 2007 Resolved
Stencil vessel name on ring buoy.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 9 May 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 18 April 2007 Resolved
Install fixed F/F system for engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2007
Resolved 9 May 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 April 2007 Resolved
Provide proof of 50% random testing for CY 2006.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 1 August 2007
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 May 2005 Resolved
Provide proof of MIS submission.
Condition: Improper/Lack of Maintenance
Due 17 June 2005
Resolved 18 May 2005
Resolution: Received faxed copy of MIS submitted.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 May 2005 Resolved
Provide proof of drills (Monthy/Quarterly), IAW 46CFR185.520 and .524.
Condition: Improper/Lack of Maintenance
Due 17 June 2005
Resolved 18 May 2005
Resolution: Training log provided, via fax.
Operations/Management › Drug and Alcohol Testing
Issued 11 May 2004 Resolved
Provide proof of MIS submission for CY 2003. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Due 11 June 2004
Resolved 14 May 2004
Resolution: MIS report submitted.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 May 2004 Resolved
Secure bolt/fasten bench seats aft stbd/port, to the deck. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2004
Resolution: Seating bolted down.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 11 May 2004 Resolved
Renew/fill halon bottle/tank, provide proof/documentation for annual service of system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2004
Resolution: Halon bottle renewed, proof of annual service provided.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 11 May 2004 Resolved
Repair gasoline/explosive gas detection alarm system. System test failed to give audible alarm as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2004
Resolution: Gasoline/explosive gas detection alarm system tested sat.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 August 2003 Resolved
Stencil vsl name on all lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2003
Resolution: Jackets stenciled
Construction/Loadline › Penetrations › Bottom Plug
Issued 6 August 2003 Resolved
Install proper pipe plug, to abandon airline penetration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2003
Resolution: Plug installed, tested satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 August 2003 Resolved
Vessel limited to daylight ops, until nav lts installed/demonstrated to satisfation of attending CG [name withheld]: Navigation Lights
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 18 April 2006
Construction/Loadline
Issued 29 March 2001 Resolved
Provide a permanent mark IAW NVIC 1-01 indicating the minimum freeboard of 15 1/2" on the vessel's stern.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Lifesaving
Issued 29 March 2001 Resolved
Prior to operating with passengers, demonstrate a satisfactory fire, abandon ship & man overboard drills and underway operational tests.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Documentation
Issued 29 March 2001 Resolved
Provide for USCG review, a company Operations Manual IAW NVIC 1-01.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Engineering
Issued 29 March 2001 Resolved
Prior to operating with passengers, prove proper operation of all vapor detector alarms.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Accommodation/Occupational Safety
Issued 29 March 2001 Resolved
Aftermost P/S passenger seats shall not be installed aft of the vessel's transom (original stern).
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Accommodation/Occupational Safety
Issued 29 March 2001 Resolved
Relocate #3 & 4 P/S vertical canopy supports to allow unobstructed egress prior to carrying passengers in those seats.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Unknown
Issued 12 July 1999 Resolved
PROVE COMPLIANCE WITH EMPLOYER SPONSORED DRUG TESTING PROGRAM.
Condition: Unknown
Due 15 July 1999
Resolved 5 August 1999
Unknown
Issued 12 July 1999 Resolved
PROVIDE CG APPROVED CREW SAFETY, TRAINING AND MAINTENANCE MANUAL.
Condition: Unknown
Due 3 August 1999
Resolved 5 August 1999
Lifesaving
Issued 27 May 1999 Resolved
CONDUCT EMERGENCY DRILLS AND "NEW TO ZONE" INSPECTION TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 27 May 1999 Resolved
PROVIDE FIRST AID KIT APPROVED IN ACCORDANCE WITH 46 CFR.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Fire Fighting
Issued 27 May 1999 Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Construction/Loadline
Issued 9 March 1999 Resolved
INSTALL RUN INDICATOR FOR AUTOMATIC BILGE PUMPS.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Construction/Loadline
Issued 9 March 1999 Resolved
INSTALL BILGE HIGH LEVEL ALARMS IAW 46 CFR 182.530.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Fire Fighting
Issued 9 March 1999 Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM IAW 46 CFR 182.480.
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Lifesaving
Issued 12 March 1998 Resolved
Separate adult and child PFD stowage.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
Properly mark adult and child PFD stowage.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
Provide a USCG approved ring buoy with 50' of line.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Fire Fighting
Issued 12 March 1998 Resolved
Provide one B-II portable fire extinguisher.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Navigation
Issued 12 March 1998 Resolved
Provide emergency steering tiller.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998
Lifesaving
Issued 12 March 1998 Resolved
Provide a first aid kit.
Condition: Unknown
Due 12 March 1998
Resolved 12 March 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.