MAURY USCG vessel records Sign in
← All vessels

MISS CARSON

MISS CARSON is a 1944 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1994, most recently in April 2026, along with 109 deficiencies.

Records from 1994 to 2026. Most recent: inspection, 27 April 2026.

Built
1944
Last inspected
27 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

401462
Flag
UNITED STATES
—
Maury page id
psix-401462

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1994–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

27 April 2026 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361610
17 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113981
3 June 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7926293
20 February 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7879146
13 December 2023 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848774
29 March 2023 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7660400
24 March 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7430174
5 March 2021 COI Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150963
15 July 2020 COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002694
18 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6837295
26 March 2019 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660446
24 October 2018 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580056
25 July 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507172
19 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6395638
8 March 2017 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6101685
9 April 2016 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5851846
17 February 2012 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 4246226
2 November 2010 Examination of Repairs
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3883866
19 February 2010 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3682352
14 December 2009 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3650060
24 July 2009 Examination of Repairs
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3544314
9 April 2009 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3451610
3 March 2009 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3430493
3 November 2008 In-Service Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3356467
14 February 2008 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3148053
6 February 2008 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3144196
28 June 2007 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2976932
23 April 2007 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2915383
13 October 2006 Simplified Stability Test
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2850055
2 March 2006 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2594838
1 March 2005 COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2301357
23 March 2004 Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2034186
7 May 2003 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 1788597
3 April 2003 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 2025365
17 March 2003 Hull Examination · Periodic Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 1736902
3 April 2002 Administrative Inspection · Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1601155
20 February 2002 Periodic Inspection · Hull Examination · Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1493959
1 August 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1068884
12 June 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1070650
11 May 2001 Administrative
Administrative · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1068358
24 April 2001 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1063309
27 March 2001 Re-Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1458856
9 April 2000 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1050615
9 March 2000 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1463566
13 October 1999 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 786991
10 May 1999 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1131222
22 February 1999 Re-Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1390948
27 May 1998 Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1127029
4 March 1998 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1416664
11 March 1997 COI Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1448898
13 March 1996 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1082635
15 March 1995 Re-Inspection
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1136063
17 February 1994 Initial Certification · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 853629

Deficiency record · 109

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 April 2026 Resolved
At each initial and subsequent inspection all accessible parts of the hull shall be inspected. During the water side inspection of the hull a crack was found near midship. During the underway portion of the inspection the crack allowed water to penetrate and collect in the rear port bilge. Operator must submit a repair proposal and conduct repairs in accordance with the approved proposal and notify MSD Fort Smith when complete to conduct underway tests on repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2026
Resolved 2 June 2026
Resolution: Owner cropped and renewed wasted metal and conducted a satisfactory float test with MSD Fort Smith Inspectors
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024 Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2024
Resolution: New Stability letter issued 10OCT2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 March 2023 Resolved
Fire Extinguishing Systems on board the vessel inspection dates were over due. Owner shall ensure the Fire fighting equipment is maintained and maintenance schedules are within a annual period.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner had fire extingushing equipment inspected by outside source. All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2023 Resolved
Vessel port aft bilge pump was not capable to discharge water from the compartment due to a broken propeller. Owner replaced the bilge pump while on-site.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2023
Resolution: Owner installed new bilge pump of same GPM. All Sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2023 Resolved
Drug and Alcohol program (DAPI) was unavailable during inspection. Owner shall submit DAPI program to MSD Fort Smith inspector within 7 Days.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner was able to send a copy of the DAPI program through email. All Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 24 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 24 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022 Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 28 April 2022
Resolved 28 April 2022
Resolution: Vessel owner installed valve to show the fuel valve is open or shut.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021 Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: COI installed in lockbox on vessel due to open vessel design.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021 Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid stability letter on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: Stability Letter is onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Child sized life jackets are stowed separately.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All electrical equipment and circuits must be clearly marked and identified. The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: NAV lights clearly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2021 Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew. The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Installed new First Aid Kit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All vessels must have navigation lights that are in compliance with Inland Navigation Rules. Navigation lights were not illuminating due to faulty fuse.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced fuse.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 March 2021 Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placards either missing or not visible to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Placard installed in visible location of overhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. 01 Child and 02 Adult size life jackets need retroreflective tape replaced.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2021 Resolved
At each inspection for certification the owner/operator shall be prepared to test the steering system to determine they are in suitable condition and fit for service intended. During testing, rudder stock was found to be leaking at the hull penetration.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2021 Resolved
At each inspection for certification the owner/operator shall be prepared to conduct tests of the main propulsion machinery. During testing, the prop shaft seal was found to be leaking.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020 Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2020
Resolved 15 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020 Resolved
Clean bilge of all debris and oil.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 August 2020
Resolved 19 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2020 Resolved
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2020
Resolved 19 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 July 2020 Resolved
Label life ring
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 August 2020
Resolved 19 August 2020
Documentation › Certificates/Documents › Stability Letter
Issued 17 February 2012 Resolved
While preparing for inspection, noticed the total persons allowed on the COI (31) did not moatch the total persons allowed on the Stability Letter (30). Vessel limited to 29 passengers until new COI is issued.
Due 3 March 2015
Resolved 17 October 2016
Resolution: Amended COI.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 3 March 2010 Resolved
Properly secure the vapor detector in the stern compartment.
Action required: 705 - Other - as specified
Due 3 April 2010
Resolved 11 May 2010
Engineering › Bilge Water Management System › Pump
Issued 7 July 2009 Resolved
Owner of vessel failed to obtain approval or notify the COTP of the changing of the bilge pumping system. The Higgens pump was replaced and noticed during the spot check.
Action required: 705 - Other - as specified
Due 7 July 2009
Resolved 18 April 2016
Resolution: CG personnel were notified when they saw the change during the spot check.
Fire Fighting › Fire Bucket › Stenciling
Issued 3 March 2009 Resolved
Fire Buckets not stenciled
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 March 2009 Resolved
Forward fuel shut off valve not labeled
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Engineering › Gasoline Engine (propulsion) › Valve Cover (4 cycle)
Issued 3 March 2009 Resolved
Starboard valve cover missing vent / fill cap.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 March 2009 Resolved
Throughout the vessel, plastic straps were used to attach wires to the vessel's hull.
Condition: Improper Installation
Due 18 March 2009
Resolved 9 April 2009
Engineering › Gasoline Engine (propulsion) › Hose, Cooling System (4 cycle)
Issued 3 March 2009 Resolved
Plastic straps were used to attach vital system hoses to the vessel's hull.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2009
Resolved 11 March 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 March 2009 Resolved
Excessive oil and debris inside bilges
Condition: Improper/Lack of Maintenance
Due 11 March 2009
Resolved 6 March 2009
Engineering › Gasoline Engine (propulsion) › Exhaust Piping (4 cycle)
Issued 3 March 2009 Resolved
Exhaust guards not mounted
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 March 2009 Resolved
Children lifejacket stowed location not appropriately marked as 46 CFR 180.78 (a) (5)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2009
Construction/Loadline › Markings › Load Line Mark
Issued 3 March 2009 Resolved
Freeboard load line not marked on the hull of the vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009 Resolved
Closure devices for ventilation to engine compartment unable to close due to obstruction on both sides
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009 Resolved
Fire wall needs to extend down to the hull in order to create a segregated engine compartment for fire fighting purposes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 3 March 2009 Resolved
Segregate fuel tank compartment to ensure efficiency of fixed fire protection system
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 11 March 2009
Construction/Loadline › Hull › Weld
Issued 3 March 2009 Resolved
Minor leak from rear carrier bearing plate. Excessive weld material on upper corners.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2009
Resolution: Water tested- All Sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 February 2008 Resolved
Aft fuel shut off valve not labeled. Fuel shut off valve needs to be marked with name and directions showing which way is on and off.
Condition: Improper Installation
Due 13 February 2008
Resolved 14 February 2008
Resolution: Fuel shut off valve labeled with directions.
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 6 February 2008 Resolved
08 adult lifejackets.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2008
Resolution: Corrected on the spot.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 February 2008 Resolved
A cotter pin holding the rear drive shaft support was missing. It was the aft outside port pin.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2008
Resolved 6 February 2008
Resolution: The pin was replaced prior to Coast Guard inspectors departure.
Engineering › Bilge Water Management System › Pump
Issued 23 April 2007 Resolved
Clean or replace bilge pump operation float switch to restore proper operation as per manufacture instructions. 46 CFR 182.520.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 24 April 2007
Electrical › Electrical Distribution System (service) › Cable
Issued 23 April 2007 Resolved
Remove all dead in cables not in use. 46 CFR 183
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Engineering › Gasoline Engine (propulsion) › Hose, Cooling System (4 cycle)
Issued 23 April 2007 Resolved
Remove all unused hoses. 46 CFR 182
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 30 May 2007
Stability › Unintentional Flooding › General
Issued 23 April 2007 Resolved
Repack or replace shaft packing as per manufacture instructions. 46 CFR 182
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2007
Resolution: replaced.
Stability › Watertight Integrity › Coaming
Issued 3 October 2006 Resolved
Vessel is required to extend the watertight coaming around the aft deck area. The coaming is to be watertight to a height of 12" above the after deck.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 24 April 2007
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 8 March 2006 Resolved
Install fixed fire extinguishing systems back on vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 2 March 2006 Resolved
Service portable extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2006
Construction/Loadline › Hull › Bottom Plating
Issued 2 March 2006 Resolved
Make proper repair to small hole in bottom plating on stbd side 6" up and 4" in from aft wheelwell in way of the chime.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 8 March 2005 Resolved
11 lifejackets need reflective tape renewed in accordance with (IAW) 46 CFR 185.604 (h). Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 March 2005 Resolved
Mark all lifejackets onboard with the Vessel (vsl) name IAW 46 CFR 185.604 (b). Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 March 2005 Resolved
Provide proof of annual service on all vsl portable fire extinguishers IAW 46 CFR 176.810(b)(1). Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 March 2005 Resolved
Provide proof of annual service on vsl's fixed fire extinguisher IAW 46 CFR 176.810(b)(1). Prior to 01 Apr 2005.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 1 April 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 March 2005 Resolved
Make repairs and/or alterations to firewall so that it is MORE vapor tight. NVIC 01-01 encloser 1 page 27. Prior to 08 APR 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 9 March 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 March 2005 Resolved
Replace missing cap screw and lock washer on the stbd side of the fwd retaining bracket. NVIC 01-01. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 March 2005 Resolved
Post donning placard for vsl's life jackets. 46 CFR 185.516(a). Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Documentation › Markings/Placards › Warning Signs
Issued 8 March 2005 Resolved
Post no smoking signs on vsl. NVIC 01-01 page 22. Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 8 March 2005 Resolved
Post oil pollution placard at each bilge control station. IAW 33 CFR 155.450. Prior to 08 Apr 2004.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Documentation › Markings/Placards › Garbage Placard
Issued 8 March 2005 Resolved
Post MARPOL Placard. IAW 33 CFR 151.59 (a)(I). Prior to 08 Apr 2005.
Action required: 705 - Other - as specified
Due 8 April 2005
Resolved 8 April 2005
Documentation › Manuals/Policy Documentation
Issued 23 March 2004 Resolved
Provide Company Operations Manual for review. LEGACY COMPONENT DESC: Operations Manual
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 23 March 2004
Resolution: Company Operations Manual provided for review.
Documentation › Manuals/Policy Documentation
Issued 23 March 2004 Resolved
Provide Emergency Response Manual for review. LEGACY COMPONENT DESC: Emergency Response Manual
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 23 March 2004
Resolution: Emergency Response Manual provided for review.
Documentation › Logs/Records
Issued 23 March 2004 Resolved
Provide vessels name on passenger count log. LEGACY COMPONENT DESC: Logbook (official)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Vessels name provided on passenger count log.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Make repairs to the vapor barrier in the engine space. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Effected repairs to the vapor barrier in the engine space.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Make the fuel tank space vapor tight. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Fuel tank made space vapor tight.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 23 March 2004 Resolved
Provide evidence of 50% First Aid and CPR card. LEGACY COMPONENT DESC: First Aid
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 1 June 2004
Personnel › Certificates/Documents/Licenses
Issued 23 March 2004 Resolved
Provide copies of Masters' Licenses for review. LEGACY COMPONENT DESC: License, Master
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 23 March 2004
Resolution: Copies of Masters'''''''' licenses provided for review..
Accommodation/Occupational Safety › Medical/First Aid
Issued 23 March 2004 Resolved
Provide on board a USCG approved First Aid Kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Approved First Aid Kit provided on board.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Replace missing cap screw on hinge assembly in way of the forward shaft housing. LEGACY COMPONENT DESC: Hinge Assembly
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2004
Resolved 29 April 2004
Resolution: Missing cap screw on hinge assembly in way of the forward shaft housing replaced.
Construction/Loadline › Structures
Issued 23 March 2004 Resolved
Remove unused rear axle vent hoses and cap off. LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2004
Resolved 29 April 2004
Resolution: Unused rear axle vent hoses removed and capped off.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 March 2003 Resolved
Maintain fixed fire extinguishers semi annualy IAW manufacturers instructions.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: All extinguishers inspected and tagged.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 March 2003 Resolved
Reposition aft fixed fire extinguisher so that pressure guage is readable.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: Extinguisher repositioned to forward bulkhead.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 March 2003 Resolved
Replaced deteoriated PFD's. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: Worn PFDs replaced in kind.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 March 2003 Resolved
Relabel PFD with vessel name. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: PFDs relabled with vessel name.
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 March 2003 Resolved
Segregate child PFD's from adult PFD's. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 19 April 2003
Resolved 6 May 2003
Resolution: Adult and child PFDs properly segregated.
Engineering
Issued 17 March 2003 Resolved
Remove non functionin, driver side, forward, brake line.
Condition: Improper/Lack of Maintenance
Due 19 April 2003
Resolved 6 May 2003
Resolution: Non functioning brakeline removed and thru hull plugged.
Operations/Management › Drills/Instruction
Issued 20 February 2002 Resolved
Provide and post Emergency Instructions in accordance with 46 CFR 185.510. LEGACY COMPONENT DESC: Safety Orientation
Condition: Unknown
Due 20 March 2002
Resolved 19 March 2002
Resolution: Posted instructions reviewed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 February 2002 Resolved
Install a vapor barrier between the engine compartment and the area under the passenger seating. The engine compartment area is not to exceed 125 cubic feet. LEGACY COMPONENT DESC: Quantity of Gas
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: A vapor barrier has been installed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 20 February 2002 Resolved
Prior to placing vehicle in service, remove the safety pin for engine compartment and the fuel tank compartment fixed fire extinguisher cylinder head. LEGACY COMPONENT DESC: Control Valve
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: Both safety pins have been removed.
Engineering › Fuel Oil Service System
Issued 20 February 2002 Resolved
Replace flexible fuel with SAE J-1492 hose.
Condition: Placed in Improper Service
Due 10 April 2002
Resolved 10 April 2002
Resolution: MSO Memphis received a fax letter dated 4/15/2002 from National Park Duck Tours owner/operator stating that the fuel line had been changed on 4/10/2002.
Electrical › Electric Supply System (service)
Issued 20 February 2002 Resolved
Provide and install a battery box that is corrosion resistant. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: A battery box has been installed.
Construction/Loadline › Markings
Issued 20 February 2002 Resolved
Proivde a permanent and painted mark indicating the 15.5 inches minimum freeboard at the vehicle's stern. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Unknown
Due 20 March 2002
Resolved 19 March 2002
Resolution: A permanent and painted marked has been provided.
Engineering › Shafting/Propeller Arrangements
Issued 20 February 2002 Resolved
Provide and install a total of four (04) cotter pins in way of the hinge pin on the shaft housing hinge pin assembly as per page 329 of the GM tech manual. Currently there are 2 cotter pins installed. LEGACY COMPONENT DESC: Coupling
Condition: Improper Installation
Due 20 March 2002
Resolved 19 March 2002
Resolution: All 4 required cotter pins have been provided and installed.
Construction/Loadline › Hull
Issued 20 February 2002 Resolved
Cut out and replace as original, the wasted frames welded to the vehicle's bottom plating. LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Due 17 April 2002
Resolved 10 April 2002
Resolution: MSO Memphis received a fax letter dated 4/15/2002 from National Park Duck Tours owner/operator stating the "floor barces" have been replaced.
Lifesaving
Issued 24 April 2001 Resolved
Provide for review a company operations manual as per NVIC 1-01.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Manual reviewed.
Lifesaving
Issued 27 March 2001 Resolved
PROVIDE ALL LIFEJACKETS WITH VESSEL NAME.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
SUBMIT WRITTEN PROPOSAL FOR INSTALLATION OF CANOPY AS PER NVIC 1-01 FOR EGRESS.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
PLUG UNUSED HOLES LOCATED ADJACENT TO HEADLIGHTS PORT/ STARBOARD SIDES.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 27 March 2001 Resolved
SUBMIT WRITTEN PROPOSAL FOR INSTALLATION OF PRE-ENGINEERED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Sea-Fire FE 241 Model FE 125 A fixed system installed. USCG 162.029/238/0.
Lifesaving
Issued 27 March 2001 Resolved
IN ACCORDANCE WITH 46 CFR 185.516(a) POST THE LIFEJACKET DONNING INSTRUCTIONS IN A CONSPICUOUS LOCATION.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
PROVIDE A PERMANENT (WELDED BEAD OR PUNCHED MARK) AND PAINTED MARK INDICATING MINIMUM FREEBOARD AT VESSEL'S STERN.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Not resolved. Re-issued in MISLE with compliance date of 3/20/2002.
Fire Fighting
Issued 27 March 2001 Resolved
PROVIDE AND POST INSTRUCTIONS FOR THE INSTALLED FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001 Resolved
PROVIDE VALVES/PIPING FOR KEEL COOLER.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Fire Fighting
Issued 27 March 2001 Resolved
INSTALL MECHANISM THAT WILL PERMIT OPERATOR TO CLOSE ENGINE COMPARTMENT HATCH COVER.
Condition: Unknown
Due 31 December 2001
Resolved 20 February 2002
Resolution: Mechanism installed and tested.
Construction/Loadline
Issued 27 March 2001 Resolved
INSTALL GASKET IN WAY OF FORWARD HATCH COVER ON ENGINE COMPARTMENT.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
PRIOR TO CARRYING PASSENGERS, ENSURE ALL HINGE PLATE ASSEMBLIES HAS A MINIMUM OF 2 CAP SCREWS/LOCK WASHERS AND PROPERLY INSTALL ALL 3 CAP SCREWS.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
STARBOARD SIDE OF DIFFERENTIAL EXTERIOR HULL PLATING NEEDS PRIMER.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001 Resolved
REPAIR/INSTALL MUFFLER SUPPORT MISSING IN ENGINE COMPARTMENT.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001 Resolved
INSTALL EXHAUST PIPE GASKET AT THROUGH HULL.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Lifesaving
Issued 27 March 2001 Resolved
PROVIDE LIFERING WITH VESSEL NAME.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 27 March 2001 Resolved
SECURE FUEL LINE LOCATED INSIDE ENGINE COMPARTMENT.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Construction/Loadline
Issued 27 March 2001 Resolved
CROP AND RENEW AS ORIGINAL WASTED FLOOR FRAMES.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Not resolved. Re-issued with compliance date of 3/20/2002.
Engineering
Issued 27 March 2001 Resolved
PROVIDE/INSTALL AFT FUEL COMPT FUEL SHUTOFF VALVE.
Condition: Unknown
Due 31 August 2001
Resolved 20 February 2002
Resolution: Valve installed.
Fire Fighting
Issued 9 March 2000 Resolved
Complete annual servicing of fixed CO2 system prior to carrying passengers.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Lifesaving
Issued 9 March 2000 Resolved
Post Emergency Instructions as per 46 CFR 185.510.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 22 February 1999 Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM IAW 46 CFR 182.480.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Lifesaving
Issued 4 March 1998 Resolved
Provide a first aid kit.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 4 March 1998 Resolved
Install 50' line on ring buoy.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Lifesaving
Issued 4 March 1998 Resolved
Provide 4 adult Type I life preservers. Vessel is restricted to the carriage of a total of 29 persons until this requirement is corrected.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Navigation
Issued 4 March 1998 Resolved
Prove proper operation of vessel's navigation lights.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.