MAURY USCG vessel records
← All vessels

MISS CARSON

Built
1944
Last inspected
27 April 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

401462
Flag
UNITED STATES
Maury page id
psix-401462

Documentation record

Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

27 April 2026 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8361610
17 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8113981
3 June 2024 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7926293
20 February 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7879146
13 December 2023 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7848774
29 March 2023 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7660400
24 March 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7430174
5 March 2021 COI Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7150963
15 July 2020 COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7002694
18 July 2019 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6837295
26 March 2019 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6660446
24 October 2018 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6580056
25 July 2018 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6507172
19 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6395638
8 March 2017 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6101685
9 April 2016 Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 5851846

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 April 2026 Resolved
At each initial and subsequent inspection all accessible parts of the hull shall be inspected. During the water side inspection of the hull a crack was found near midship. During the underway portion of the inspection the crack allowed water to penetrate and collect in the rear port bilge. Operator must submit a repair proposal and conduct repairs in accordance with the approved proposal and notify MSD Fort Smith when complete to conduct underway tests on repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2026
Resolved 2 June 2026
Resolution: Owner cropped and renewed wasted metal and conducted a satisfactory float test with MSD Fort Smith Inspectors
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 January 2024 Resolved
Vessel is under going the modifications required by 46CFR175.124. Vessel will not be able to carry passengers in accordance with the COI until the requirements of the regulations are met.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2024
Resolution: New Stability letter issued 10OCT2024
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 29 March 2023 Resolved
Fire Extinguishing Systems on board the vessel inspection dates were over due. Owner shall ensure the Fire fighting equipment is maintained and maintenance schedules are within a annual period.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner had fire extingushing equipment inspected by outside source. All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2023 Resolved
Vessel port aft bilge pump was not capable to discharge water from the compartment due to a broken propeller. Owner replaced the bilge pump while on-site.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2023
Resolution: Owner installed new bilge pump of same GPM. All Sat
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2023 Resolved
Drug and Alcohol program (DAPI) was unavailable during inspection. Owner shall submit DAPI program to MSD Fort Smith inspector within 7 Days.
Action required: 705 - Other - as specified
Due 5 April 2023
Resolved 10 May 2023
Resolution: Owner was able to send a copy of the DAPI program through email. All Sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the port side for the radiator hoses. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 24 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2022 Resolved
Vessel does not have shut off valves at the hull penetrations on the front of the engine compartment for the hoses going to the deferential of the axle. Install valves in this location with in 30 days.
Action required: 705 - Other - as specified
Due 24 April 2022
Resolved 28 April 2022
Resolution: Vessel Owner installed ball valves at the hull penetration's connection for the hose.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 March 2022 Resolved
Vessel operator is unable to show the fuel is shut off after operating the emergency fuel shut off. Owner shall provide an indicator for the fuel shut off.
Action required: 705 - Other - as specified
Due 28 April 2022
Resolved 28 April 2022
Resolution: Vessel owner installed valve to show the fuel valve is open or shut.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 March 2021 Resolved
The COI shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the certificates must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid COI on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: COI installed in lockbox on vessel due to open vessel design.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 5 March 2021 Resolved
The stability letter shall be kept on board the vessel under glass or suitable transparent material, if impracticable, the stability letter must be kept on board in a weather tight container readily available for use by the crew and display to passengers and others on request. The vessel does not maintain a valid stability letter on board the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2021
Resolution: Stability Letter is onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child size life jackets are not stowed separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Child sized life jackets are stowed separately.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All electrical equipment and circuits must be clearly marked and identified. The Navigation lights at the operating station are not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: NAV lights clearly marked.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 March 2021 Resolved
A vessel must carry a first aid kit approved under 160.041 or an equivalent kit, must be easily visible and readily available to the crew. The kit on board was expired.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Installed new First Aid Kit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2021 Resolved
All vessels must have navigation lights that are in compliance with Inland Navigation Rules. Navigation lights were not illuminating due to faulty fuse.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced fuse.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 March 2021 Resolved
Placards containing instructions for the donning and use of life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket donning placards either missing or not visible to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 June 2021
Resolution: Placard installed in visible location of overhead.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. 01 Child and 02 Adult size life jackets need retroreflective tape replaced.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
Resolution: Replaced life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2021 Resolved
At each inspection for certification the owner/operator shall be prepared to test the steering system to determine they are in suitable condition and fit for service intended. During testing, rudder stock was found to be leaking at the hull penetration.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 March 2021 Resolved
At each inspection for certification the owner/operator shall be prepared to conduct tests of the main propulsion machinery. During testing, the prop shaft seal was found to be leaking.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 July 2020 Resolved
Replace seals around engine compartment hatch, front ventilation hatch and rear door.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2020
Resolved 15 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 15 July 2020 Resolved
Clean bilge of all debris and oil.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 August 2020
Resolved 19 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 July 2020 Resolved
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2020
Resolved 19 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 July 2020 Resolved
Label life ring
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 August 2020
Resolved 19 August 2020

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.