Records from 1994 to 2012. Most recent: operational control imposed, 9 January 2012.
Inspection history · 18
9 January 2012
PII Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4215354
5 January 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4215353
28 January 2010
MARPOL Annex VI Survey · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3667625
12 August 2008
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3331091
6 August 2008
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3316885
19 February 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3149528
10 June 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2386330
29 March 2005
Ballast Water Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2321421
10 December 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1961923
18 March 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 288266
23 August 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 432058
18 September 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 469139
11 January 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 411747
27 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 166194
22 July 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 393283
19 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380849
18 July 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 499632
22 February 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 364789
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 January 2012
Resolved
1730-Oily-water separating equipment-OWS will not provide an effluent sample to the OCM while the system is in the run position. The three way sample valve allows only freshwater to enter the OCM while the system is in the run/operate mode and effluent/sample water when the three way valve is in the cleaning mode.-MARPOL 73/78 Annex I/14, MEPC 107(49)
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2012
Resolved 10 January 2012
Resolution: Received, reviewed and accepted class report from Korean Register of Shipping stating the deficiency was rectified. Three-way sample valve was repositioned. OWS/OCM was tested to the satisfaction of the class surveyor.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 March 2005
Resolved
The emergency generator is inoperable due to a broken shaft bearing, fan, radiator, and cooling water pump.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2005
Resolved 11 April 2005
Resolution: Rcvd class report stating that the emergency generator''s cooling water pump, fan, and radiator were replaced at this time. The generator was run on load for 30 minutes and found satisfactory. Cleared deficiency and rescinded restriction.
Documentation
Issued 22 February 1994
Resolved
OIL TRANSFER PROCEDURES WERE NOT COMPLETE.
Condition: Unknown
Due 22 February 1994
Resolved 24 February 1994