MAURY USCG vessel records Sign in
← All vessels

LOGAN

LOGAN is a 1993 freight ship. The Coast Guard has recorded 15 inspections since 1994, most recently in April 2009, along with 12 deficiencies.

Records from 1994 to 2009. Most recent: inspection, 27 April 2009.

Built
1993
Last inspected
27 April 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9035084 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
401506
Flag
LIBERIA
—
Maury page id
psix-401506

Inspections, by type

…with no type recorded11
Years with a record 9 calendar years (1994–2009)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7800 - Regulatory (Subpart C or D), Gross Ton
3575 - Regulatory (Subpart C or D), Net Ton
8023 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

27 April 2009 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3461966
24 January 2006 MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2568752
24 January 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2572054
17 February 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2294620
11 February 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2290767
6 February 2005 ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2287481
3 December 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1713476
26 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286486
6 November 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 274143
24 February 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 400805
29 January 1997 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 399894
17 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 692850
14 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 443326
23 January 1995 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 374523
25 February 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 458797

Deficiency record · 12

Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 January 2006 Resolved
Forward catwalk steps are corroded and fractured.
Condition: Improper/Lack of Maintenance
Due 24 February 2006
Resolved 3 July 2006
Resolution: Received photo of repaired catwalk steps.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 January 2006 Resolved
Install cover over emergency gernerator battery terminals. Shock hazard.
Condition: Design Flaw
Due 24 February 2006
Resolved 3 July 2006
Resolution: Received photo of installed cover over emergency generator battery terminals.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 24 January 2006 Resolved
Life rafts are installed without painter made to ship with weak link. Installation would not deploy raft. Install weak link between painter and ship prior to departure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2006
Resolved 26 January 2006
Resolution: Master provided documentation and raft schematics which verified the life raft installation met SOLAS requirements.
Deck/Cargo
Issued 24 February 1997 Resolved
Hawse pipe covers for Port & Stbd Anchors are missing. Provide new covers.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 24 February 1997 Resolved
Bunker line hydrostatic test out of date (OCT95). Conduct hydrostatic test of bunker line prior to next U.S. bunker.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Navigation
Issued 24 February 1997 Resolved
Chart 11503 or foreign equivalent required for the safe navigation for the Port of Fernandina is not onboard. Provide currently corrected to date chart.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Accommodation/Occupational Safety
Issued 24 February 1997 Resolved
Portside rail in way of #3 Cargo hold. Repair as original.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 24 February 1997 Resolved
Bunker station containment does not have a mechanical means of closure for drains. Provide mechanical means of closure prior to next U.S. bunkering.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Fire Fighting
Issued 24 February 1997 Resolved
Fire drill unsatisfactory, prior to departure vessel to conduct satisfactory fire drill for the cognizant [name withheld] intervention imposed on vessel.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Documentation
Issued 23 January 1995 Resolved
vessels oil transfer procedures did not list each product including genericor chemical name.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Documentation
Issued 23 January 1995 Resolved
MASTER OF THE VESSEL COULD NOT PRODUCE VALID MEDICAL EXAMINATION CERTIFICATES AS REQUIRED BY ILO147._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Navigation
Issued 23 January 1995 Resolved
vessel did not conduct or log pre-arrival test IAW 33 CFR 164.25.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995