Records from 1994 to 2009. Most recent: inspection, 27 April 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
27 April 2009
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3461966
24 January 2006
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2568752
24 January 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2572054
17 February 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2294620
11 February 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2290767
6 February 2005
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2287481
3 December 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1713476
26 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286486
6 November 1999
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 274143
24 February 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 400805
29 January 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 399894
17 March 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 692850
14 March 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 443326
23 January 1995
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 374523
25 February 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 458797
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 January 2006
Resolved
Forward catwalk steps are corroded and fractured.
Condition: Improper/Lack of Maintenance
Due 24 February 2006
Resolved 3 July 2006
Resolution: Received photo of repaired catwalk steps.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 January 2006
Resolved
Install cover over emergency gernerator battery terminals. Shock hazard.
Condition: Design Flaw
Due 24 February 2006
Resolved 3 July 2006
Resolution: Received photo of installed cover over emergency generator battery terminals.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 24 January 2006
Resolved
Life rafts are installed without painter made to ship with weak link. Installation would not deploy raft. Install weak link between painter and ship prior to departure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2006
Resolved 26 January 2006
Resolution: Master provided documentation and raft schematics which verified the life raft installation met SOLAS requirements.
Deck/Cargo
Issued 24 February 1997
Resolved
Hawse pipe covers for Port & Stbd Anchors are missing. Provide new covers.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 24 February 1997
Resolved
Bunker line hydrostatic test out of date (OCT95). Conduct hydrostatic test of bunker line prior to next U.S. bunker.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Navigation
Issued 24 February 1997
Resolved
Chart 11503 or foreign equivalent required for the safe navigation for the Port of Fernandina is not onboard. Provide currently corrected to date chart.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Accommodation/Occupational Safety
Issued 24 February 1997
Resolved
Portside rail in way of #3 Cargo hold. Repair as original.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 24 February 1997
Resolved
Bunker station containment does not have a mechanical means of closure for drains. Provide mechanical means of closure prior to next U.S. bunkering.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Fire Fighting
Issued 24 February 1997
Resolved
Fire drill unsatisfactory, prior to departure vessel to conduct satisfactory fire drill for the cognizant [name withheld] intervention imposed on vessel.
Condition: Unknown
Due 12 March 1997
Resolved 12 March 1997
Documentation
Issued 23 January 1995
Resolved
vessels oil transfer procedures did not list each product including genericor chemical name.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Documentation
Issued 23 January 1995
Resolved
MASTER OF THE VESSEL COULD NOT PRODUCE VALID MEDICAL EXAMINATION CERTIFICATES AS REQUIRED BY ILO147._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Navigation
Issued 23 January 1995
Resolved
vessel did not conduct or log pre-arrival test IAW 33 CFR 164.25.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995