Records from 2010 to 2025. Most recent: inspection, 14 August 2025.
Inspection history · 29
14 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8180671
4 August 2025
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8317690
12 February 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8081023
24 September 2024
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 8009467
1 August 2024
Internal Structural Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7972570
22 January 2024
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7853012
6 November 2023
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7820923
4 October 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7807145
18 July 2023
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7746029
30 January 2023
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7629439
5 August 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7528469
7 July 2022
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7498552
17 August 2021
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7290392
28 July 2021
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7270671
28 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7067323
18 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7038659
24 February 2020
Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6925655
24 June 2019
Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6724528
21 February 2019
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6630129
2 July 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6468185
12 March 2018
Drydock Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6370768
2 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6364782
20 October 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6291805
11 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6264599
27 July 2017
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6222943
2 June 2017
Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6163535
28 March 2017
COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6113211
19 January 2017
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6073497
8 February 2016
Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5811732
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 September 2024
Resolved
Forward engine room bulkhead was found wasted and holed in the upper port corner in way of the fire main. After discussing repair plan with the local CG office, make permanent repairs to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 30 March 2025
Resolved 14 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 September 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Rotating belt on generator is not shielded.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Shore - Ship
Issued 24 September 2024
Resolved
Where necessary for safety of personnel, grab rails shall be provided. Port outboard hand rail is wasted and must be repaired/renewed.
Action required: 705 - Other - as specified
Due 30 March 2025
Resolved 14 February 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 September 2024
Resolved
Sidelights should show an unbroken light over an arc of the horizon of 112.5 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on its respective side. Vessel sidelights show beyond ahead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 September 2024
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Starboard engine room high level alarm is sticking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 August 2024
Resolved
Stations in maritime service must be lisenced by the FCC. Vessel station license, Bridge to Bridge license and Radio Safety Telephony Certificate were expired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2024
Resolved 9 August 2024
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 21 March 2024
Resolved
Void 8 - Stbd bow main deck is wasted, but appears to remain dry by ramp closure structure above wasted deck. Make proposal for temp repair. Make permanent repair at next scheduled internal structural exam (NLT 31JUL24).
Action required: 705 - Other - as specified
Due 31 July 2024
Resolved 14 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2023
Resolved
On vessels of 65 ft or more, each fire hose must conforms to UL 19. The aft fire hose was found to be leaking.
46 CFR 181.320(b)1
Action required: 10 - Deficiency Rectified
Due 4 October 2023
Resolved 5 October 2023
Resolution: Replaced hose
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 4 October 2023
Resolved
At each initial and subsequent inspection the O/O shall have the vessel ready for inspection to include; the inspection and operation of all watertight closures in the hull. Vessel was found to have a hole in the deck, IWO the starboard/ aft superstructure, leading into the engine room. Temp repair made till Dry-Dock. 46 CFR 176.802 (a)2
Action required: 705 - Other - as specified
Due 4 October 2023
Resolved 20 March 2024
Resolution: Repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 October 2023
Resolved
At each initial and subsequent inspection the O/O shall have the vessel ready for inspection to include; the inspection and operation of all watertight closures in the hull. The port cutlass bearing was found to be leaking excessively.
46 CFR 176.802 (a) 2
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: cutlass bearing repacked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2023
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. The vessel's engine room was missing the required lagging. 46 CFR 182.430 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 6 November 2023
Resolution: Lagging replaced
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 October 2023
Resolved
Each life ring must be in accordance with Sub. Q. Life ring needs stenciled. 46 CFR 180.70 (b) 1
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: Markings updated
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 October 2023
Resolved
Vessel must have navigation lights in compliance with the applicable Nav Rules. Vessel's port and starboard lights can be seen from outside the arc of viability requirements. Additionally, the background is to be mat black.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 8 April 2024
Resolution: repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 October 2023
Resolved
For each marine casualty, the master or person in charge shall determine whether alcohol was involved. the Alcohol test strips were expired. 46 CFR 185.210 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 6 November 2023
Resolution: test strips on board
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 October 2023
Resolved
Remote fuel shutoffs must be marked. The old fuel shutoff's marking is still visible. Remote fuel shutoffs must be marked. The old fuel shutoff's marking is still visible.
46 CFR 185.608
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: old sign removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 October 2023
Resolved
Whenever machinery is installed aboard a vessel after completion of the initial inspection for certification, as replacement equipment or as a new installation, the owner or managing operator shall conduct the test to the satisfaction of the cognizant OCMI. The ship's generator was changed out and the OCMI was never notified. Provide tech spec info to OCMI. 46 CFR 176.702
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2023
Resolved 8 April 2024
Resolution: rcvd and added generator specs/manual to MISLE per MSU Valdez
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 4 October 2023
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III, must carry a radio operator. Crew does not have anyone who has a FCC Marine Radio Operator Permit. Vessel is restricted to < 6 passengers. 47 CFR 80.159(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2023
Resolved 6 November 2023
Resolution: Crew member obtained permit
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 October 2023
Resolved
Vessel shall instruct each crew member upon first being employed and prior to getting underway for the first time and a least once every 3 months, the duties of the crew member. To include emergency situations. Vessel has not logged drills this year. 46 CFR 185.420 (a)
Action required: 10 - Deficiency Rectified
Due 5 October 2023
Resolved 5 October 2023
Resolution: Drills conducted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 July 2022
Resolved
Bilge suctions shall be fitted with suitable strainers. Properly install strainer on all bilge suction lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 23 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2022
Resolved
The fuel shutoff valve at the tanks shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Fuel shutoff valve at day port and stb day tank not operable outside engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2022
Resolved 15 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 July 2022
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Prove proper operation of bilge suction.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2022
Resolved 14 July 2022
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 7 July 2022
Resolved
Repair cracked/wasted welds in way of port and stb second padi down used to hold bow door and around reach rod in way of main deck centerline, very front void.
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 30 January 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 July 2022
Resolved
The hull centerline, second void from front, appears to have wasted steel. Gauge hull to demonstrate proper thickness.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2022
Resolved 23 August 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 28 July 2021
Resolved
Forward engine room bulkhead was found wasted and holed in the upper port corner in way of hydraulic lines. Make permanent repairs to the satisfaction of the attending marine inspector. 46 CFR 177.300(b)
Action required: 705 - Other - as specified
Due 30 September 2021
Resolved 21 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 August 2020
Resolved
Sight glass tube on both fuel oil day tanks that are located in the engine room are not made of heat resistance material, replace tubes.
46 CFR 182.20-25(5)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 28 September 2020
Resolution: Heat resistant sight glass has been installed to both fuel oil day tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 August 2020
Resolved
Prove sight glass tube valves are in accordance with
46 CFR 182.20-25(5) quick closing type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 28 September 2020
Resolution: New quick closing sight tube valves have been installed to both fuel oil day tanks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2020
Resolved
Renew port side shaft bearing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2020
Resolution: After second look bearing was not worn beyond 50%
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 February 2019
Resolved
Conduct UT shots in area of where stern was arc'd through during installation of new zincs on 20FEB2019. The UT shots shall cover a min of 24"X24" area and expand if necessary until surrounding good metal is reached. 46 CFR 176.700
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2019
Resolved 13 March 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 February 2019
Resolved
Provide full UT report to MSU Valdez Inspections. Upon receipt and review of the report, MSU Valdez will determine the size of the area to be cropped & renewed. Vessel shall not depart shipyard in Cordova prior to satisfactory completion of all repairs as witnessed and determined by MSU Valdez. 46 CFR 176.700
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2019
Resolved 13 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2018
Resolved
Properly installed strainer on all bilge suction lines. 46 CFR 182.510 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 8 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 July 2018
Resolved
Make port & stbd engine tachometers operate properly. 46 CFR 182.410 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 8 August 2018
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 July 2018
Resolved
Install permanent draft marks or loading marks. 46 CFR 185.602 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 8 August 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 2 July 2018
Resolved
Provide documetation for paymet of COI inspection. 46 CFR 2.10-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 2 July 2018
Construction/Loadline › Structures › Transverse Bulkhead
Issued 24 April 2017
Resolved
FWD bulkhead in engine room must be watertight. Penetration on the stbd side.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 28 April 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 24 April 2017
Resolved
Covers for ventilation must be provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 May 2017
Resolved 26 May 2017
Construction/Loadline › Structures › Machinery Space Opening
Issued 28 March 2017
Resolved
Repair\replace steps leading into engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 26 May 2017
Accommodation/Occupational Safety › Ventilation › General
Issued 28 March 2017
Resolved
Move switch for fan outside of the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 26 May 2017
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 13 April 2016
Resolved
Remove paint and flammables out of accommodations space to proper storage locker. 46 CFR 177.405(d)
Due 18 April 2016
Resolved 15 April 2016
Resolution: Received pictures to reflect corrective action.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 April 2016
Resolved
Provide proof all crew are enrolled in a drug testing consortium. 46 CFR 16.203(a)
Due 3 May 2016
Resolved 3 May 2016
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2016
Resolved
Repair or replace stb ring buoy. 46 CFR 160.050-4
Due 3 May 2016
Resolved 3 May 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 April 2016
Resolved
Secure stb forward junction box. 46 CFR 183.220
Due 3 May 2016
Resolved 3 May 2016
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 13 April 2016
Resolved
Stencil forward water tight door "WATERTIGHT DOOR - KEEP CLOSED ". 46 CFR 185.610
Due 3 May 2016
Resolved 3 May 2016
Engineering › Fuel Oil Service System › Hose
Issued 13 April 2016
Resolved
Double clamp flexible fuel tank vent hose and fuel fill hose. 46 CFR 182.450(g)
Due 3 May 2016
Resolved 3 May 2016
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 April 2016
Resolved
Connect the metallic sections of the fuel fill with a conductor. 46 CFR 182.445(g)
Due 3 May 2016
Resolved 3 May 2016
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 April 2016
Resolved
Prove proper operation of bilge system w/o putting contaminants in the water. 46 CFR 176.804(h)
Due 3 May 2016
Resolved 3 May 2016
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 13 April 2016
Resolved
Provide cargo gear inspection report from organization recognized by the Comdt prior to crane operations. 46 CFR 91.25-25(a)(3)
Due 13 April 2016
Resolved 3 May 2016